The term “Control Valve Seat Leakage Class” comes from ANSI / FCI 70-2. This is a control valve seat leakage specification Standard.
🔴 Link to Join Advanced Instrumentation WhatsApp Community 🔴
👉 chat.whatsapp.com/G1Aon6ZnbEJ...
Valve Leakage Classifications
Class I - Valve Leakage Classifications Identical to Class II, III, and IV in construction and design intent, but no actual shoptest is made. Class I is also known as dust tight and can refer to metal or resilient seated valves.
Class II - Valve Leakage Classifications Intended for double port or balanced singe port valves with a metal piston ring seal and metal to metal seats.
• 0.5% leakage of full open valve capacity.
• Service dP or 50 psid (3.4 bar differential), whichever is lower at 50 to 125oF.
• Test medium air at 45 to 60 psig is the test fluid.
Typical constructions:
• Balanced, single port, single graphite piston ring, metal seat, low seat load• Balanced, double port, metal seats, high seat load
Class III - Valve Leakage Classifications Intended for the same types of valves as in Class II.
• 0.1% leakage of full open valve capacity.• Service dP or 50 psid (3.4 bar differential), whichever is lower at 50 to 125oF.
• Test medium air at 45 to 60 psig is the test fluid.
• Balanced, double port, soft seats, low seat load
• Balanced, single port, single graphite piston ring, lapped metal seats, medium load
Class IV - Valve Leakage Classifications
Intended for single port and balanced single port valves with extra tight piston seals and metal to-metal seats.
• 0.01% leakage of full open valve capacity.
• Service dP or 50 psid (3.4 bar differential), whichever is lower at 50 to 125oF.
• Test medium air at 45 to 60 psig is the test fluid.
Typical constructions:
• Balanced, single port, Teflon piston ring, lapped metal seats, medium seat load
• Balanced, single port, multiple graphite piston rings, lapped metal seats
• Unbalanced, single port, lapped metal seats, medium seat load
• Class IV is also known as metal to metal
Class V - Valve Leakage Classifications
Intended for the same types of valves as Class IV.
• The test fluid is water at 100 psig or operating pressure.
• Leakage allowed is limited to 5 x 10 ml per minute per inch of orifice diameter per psi differential.
• Service dP at 50 to 125 oF.
Typical constructions:
• Unbalanced, single port, lapped metal seats, high seat load
• Balanced, single port, Teflon piston rings, soft seats, low seat load
• Unbalanced, single port, soft metal seats, high seat load
Class VI - Valve Leakage Classifications
Class VI is known as a soft seat classification.
Soft Seat Valves are those where the seat, shut-off disc or both are made from some kind of resilient material such as Teflon. Intended for resilient seating valves.
• The test fluid is air or nitrogen.
• Pressure is the lesser of 50 psig or operating pressure.
• The leakage limit depends on valve size and ranges from 0.15 to 6.75 ml per minute for valve sizes 1 through 8 inches.

Пікірлер: 5
@TheHinaiibrahim
@TheHinaiibrahim 18 күн бұрын
Thanks Asad. Very useful insite on the topic
@SuperPrashant1991
@SuperPrashant1991 19 күн бұрын
Very Informative !! Please also make video on leakage class requirement for on-off valves...Thanks!!!
@AsadPassionateEngineer
@AsadPassionateEngineer 18 күн бұрын
Thanks Prashant !! Yes sure . !! 😊
@danielodeliro2412
@danielodeliro2412 21 күн бұрын
Thanks
@AsadPassionateEngineer
@AsadPassionateEngineer 18 күн бұрын
Most welcome 😊
7 Bonnet Selection Criteria in Control Valves- Explained
12:38
Asad (I&C Engineer)
Рет қаралды 1,2 М.
Control Valve's TOP 3 MOST asked INTERVIEW Question and Answers
14:25
Asad (I&C Engineer)
Рет қаралды 23 М.
Do you have a friend like this? 🤣#shorts
00:12
dednahype
Рет қаралды 57 МЛН
ПООСТЕРЕГИСЬ🙊🙊🙊
00:39
Chapitosiki
Рет қаралды 38 МЛН
5 Flange Facing types must-know for every engineer
9:03
Asad (I&C Engineer)
Рет қаралды 2,1 М.
DP Transmitter Dry Leg & Wet Leg Calculations
3:02
Set-Point
Рет қаралды 2,2 М.
Orifice BETA RATIO limit | Why does it EXISTS !!
7:09
Asad (I&C Engineer)
Рет қаралды 15 М.
Control Valve Selection (Most LOGICAL Explanation)
10:41
Asad (I&C Engineer)
Рет қаралды 3,2 М.
Control Valve Sizing Made Simple | 3 Golden Rules
9:44
Asad (I&C Engineer)
Рет қаралды 8 М.
What is a PID Controller? | DigiKey
22:19
DigiKey
Рет қаралды 62 М.
What is Safety Instrumented System | Voting 2oo3 | SIF | PFD Explained
6:47
Asad (I&C Engineer)
Рет қаралды 4,6 М.
Biggest Control Valve Sizing MISTAKE
5:14
Asad (I&C Engineer)
Рет қаралды 1 М.
Fugitive Emission Valve Standards | ISO 15848 | TA Luft | API 641
10:27
Asad (I&C Engineer)
Рет қаралды 2,1 М.
iPhone 12 socket cleaning #fixit
0:30
Tamar DB (mt)
Рет қаралды 21 МЛН
How charged your battery?
0:14
V.A. show / Магика
Рет қаралды 3,7 МЛН