Why Transformer Tap Changer is on High Voltage Winding| Tap Changer of Transformer | Hindi

  Рет қаралды 37,360

Electrical With Abhishek Joshi

Electrical With Abhishek Joshi

Күн бұрын

Пікірлер: 92
@sm-ph8uf
@sm-ph8uf Жыл бұрын
sir insulation to voltage pe depend karta hai...jis taraf current kam hoga us side voltage jada hoga to udhar jada insulation chahiye hoga
@eng.omareyadaljorani9954
@eng.omareyadaljorani9954 3 жыл бұрын
Transformer tappings are always done on the high voltage side of the transformer. High voltage side has low current and vice versa for low voltage side. When we use tappings due to the low current on the high voltage side, there will be less sparks and the turns are higher when compared to LV side ( low voltage,high current). Moreover the HV side is outside the transformer so tappings are easily done on the HV side.
@kazimabbas7098
@kazimabbas7098 3 жыл бұрын
I appreciate your efforts Sir! If i'm not wrong high class insulation is required for high voltage and conductor size increases when current level got increased.
@AmmadAsim
@AmmadAsim 3 жыл бұрын
Tap changer is provided on HV side becoz HV is the winding which controls & induces volts on LV, it's basically the supply side on which tap changer is provided.
@kazimabbas7098
@kazimabbas7098 3 жыл бұрын
@@AmmadAsim agree
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
We can do supply either on HV Side and LV side. Same transformer can work as a step up and step down transformer based on requirement.
@yunusbhadarka6006
@yunusbhadarka6006 2 жыл бұрын
Sahi baat hai
@bhuwanextrovert6799
@bhuwanextrovert6799 2 жыл бұрын
@@electricalwithabhishekjoshi sir AP telegram pr hai to please link mention kijiye ....mzhe ak tap changer KO smzhne mai problem create ho rha hai ..... Kuki sir ise tap changer mai OLTC(delta connection) and OCTC (star) connection .....
@FactsLoverHindi
@FactsLoverHindi 2 жыл бұрын
Continuously ese hi knowledgeable video bnate rhiye 🙏🙏
@omkardeshkar4725
@omkardeshkar4725 Жыл бұрын
Nicely explained...also HV side has more winding so it is easy to provide more tappings right?
@vijayshankar3456
@vijayshankar3456 3 жыл бұрын
Thank you very much dear Joshi ji now concept is clear.
@debasishdas4518
@debasishdas4518 9 ай бұрын
Sir insulation to voltage ke uper depend karta hai ager hum hv side me tap change use karenge tabhi bi to insulation jada lagega sir yeh doubt clear kardijiye
@EE-xz9hu
@EE-xz9hu 2 жыл бұрын
Sir mai aapse bat karna chahta hu...mai aapka sari video dekha hu aur subscriber v hu ..please sir 🙏🙏🙏
@AmanKumar-nm2ol
@AmanKumar-nm2ol 3 жыл бұрын
Sir aapne kaha ki HV side me current ka magnitude km hai is liye insulation km chahiye hoga Pr insulation km ya jyada hoga ye to voltage pe depend krta hai n
@anilchoudhary9545
@anilchoudhary9545 3 жыл бұрын
Right ✅
@sarojkumarmallick1387
@sarojkumarmallick1387 Ай бұрын
Sir if we apply under voltage at primary side, can transformer work properly?
@sabirhussain9820
@sabirhussain9820 3 жыл бұрын
Sir last me ek word Mistake kar diye aap, taping high voltage sides karna chahiye nahi low voltage side, Thanks
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Ho jata hai.. Thanks 👍
@justicehunt7136
@justicehunt7136 3 жыл бұрын
Nice information sir, please make video on charging methods of battery bank in substation, like floating charging and boost charging etc
@AnilAutomation
@AnilAutomation 3 жыл бұрын
#anilautomationhindi 👍
@emokhan5895
@emokhan5895 3 жыл бұрын
Sir jahn tk mujhy pta h jahn current ka magnitude ziada hota h wahn conductor ziada use krna prta jis ki wja sy costing high hoti h or jahn voltage ka magnitude ziada hota h wahn insulation ki requirement brh jati h , Or hamry han transformers pay yehi hota h k mv side pr focus insulation pay hota h or lv side pr conductor pay focus hota h.
@dchouhan123
@dchouhan123 Жыл бұрын
tap change primary me hota h ki secondary me
@chandramudulibikash9157
@chandramudulibikash9157 3 жыл бұрын
Sir transformer safety kya kya he iske uper video banaye
@m.sadiquehayat456
@m.sadiquehayat456 3 жыл бұрын
Sir jee power factor ko kysay menten karey uskey details bataye Merey pas 10 HP KY moter hai
@engineers6887
@engineers6887 3 жыл бұрын
4 kvar ka capacitor bank dal dena
@rakeshharde2325
@rakeshharde2325 3 жыл бұрын
Sir sacondry winding par jab load padta h to primary winding me bhi iska effect padta h kya
@AnilAutomation
@AnilAutomation 3 жыл бұрын
Yes #anilautomationhindi
@pavanvishwakarmatechnicalc4770
@pavanvishwakarmatechnicalc4770 3 жыл бұрын
Sir Ji cement industries me konsi cable usebl Ki jati hai under ground me or aluminium ya copper Ki
@dineshtusia968
@dineshtusia968 3 жыл бұрын
Unarmoured Power cable
@aashishsahu1536
@aashishsahu1536 Жыл бұрын
Motor ka inductance kaise change hota hai, or agar inductance change ho jae to motor me kya hoga? Sir iska ans btao..
@akshayakumarmahaling1195
@akshayakumarmahaling1195 2 ай бұрын
Sir material constant bareme ek video banaiye🙏🙏🙏
@mdsajmal4980
@mdsajmal4980 3 жыл бұрын
Sir kisi motor ko start karne ke liye star delta starter ka use karte hai To motor ke turminal me ham cable ka connction Star me kare ya delta me
@mdsajmal4980
@mdsajmal4980 3 жыл бұрын
@@AnilAutomation Sir very...... Thanks reply dene ke liye
@anilchoudhary9545
@anilchoudhary9545 3 жыл бұрын
@@AnilAutomation Galt kyu bta rhe ho , phle ache se clear kro concept
@AnilAutomation
@AnilAutomation 3 жыл бұрын
@@anilchoudhary9545 please do clear concept..🙏
@anilchoudhary9545
@anilchoudhary9545 3 жыл бұрын
@@AnilAutomationHey sir, insulation depends on voltage, where on current. What did you say in the video, where the voltage is high, the current is low. This is true, but where the voltage is high, the insulation requirement is high. Clear the concept!
@sefatullah441
@sefatullah441 3 жыл бұрын
outstanding Sir
@nirdeshsoni678
@nirdeshsoni678 Жыл бұрын
Video on RTCC panel function and it's important connection with scada
@NarendraGohil-k3q
@NarendraGohil-k3q Ай бұрын
Sir jab tape cheng ke he tab yr distortion kyo nahi hota he
@rubanbasu
@rubanbasu 2 ай бұрын
Sir transformer testing k upar ek class lijiye
@swapnilmajee3962
@swapnilmajee3962 3 жыл бұрын
How GT tap changing concept is used to adjust reactive power when reactive can no longer be adjusted by field.? Pls make a video on the concept
@ssinghrajput7626
@ssinghrajput7626 3 жыл бұрын
Sir uppcl je ke point of view se suggestion dijiye kaise taiyari kre silection ke liye
@sefatullah441
@sefatullah441 3 жыл бұрын
uppcl waly say pochay yar .. sir to cement industry may job kar raha hai... Sir say technically electrical engg k bary may pochoo.... please
@bihariyt007
@bihariyt007 Жыл бұрын
What is the fuse under PT but why not the fuse under CT
@DilbagSingh-eg1wb
@DilbagSingh-eg1wb 3 жыл бұрын
Sir g elevator ka detail mai video banao 🙏
@shahbaazahmad130
@shahbaazahmad130 2 жыл бұрын
Sir aapka 1st logic mere ko samaj me nhi aaya bcz current not is the reason for insulation As you know insulation class depends upon voltage rating
@DilbagSingh-eg1wb
@DilbagSingh-eg1wb 3 жыл бұрын
Very nice 🙏
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Thank you..
@raviendhiran5896
@raviendhiran5896 2 жыл бұрын
Nice explain
@DineshKukde-q1i
@DineshKukde-q1i 11 ай бұрын
Sir please video on topic alternator increase steam means ,load change what happened
@souravdas1558
@souravdas1558 3 жыл бұрын
Sir one video.. why Transformer frequency is not changed? .. Please🙏🙏
@TrinathTechnical
@TrinathTechnical 3 жыл бұрын
Sir why water is not used in transformer cooling,it's too cheap where all widing are insulated
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Windings are insulated but it doesn't mean that we use water in transformer. This will result in short circuit.
@rupremi
@rupremi 3 жыл бұрын
Fantastic sir
@AnilAutomation
@AnilAutomation 3 жыл бұрын
#anilautomationhindi 🙏
@AnilAutomation
@AnilAutomation 3 жыл бұрын
#anilautomationhindi Nice and clear concept
@Rudrajeetchavda1106
@Rudrajeetchavda1106 2 жыл бұрын
Tag changing time phase open hoga to tripping kyu nae aata he any other systems use in side of transformer
@manoharborvadkar2107
@manoharborvadkar2107 3 жыл бұрын
Sir please make video on transformer oil filtration and oil filling procedure
@AnilAutomation
@AnilAutomation 3 жыл бұрын
#anilautomationhindi 👍
@pramitapsatapathy5037
@pramitapsatapathy5037 2 жыл бұрын
Wonderful explanation
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 2 жыл бұрын
Thank you Pramitap..
@rajeevranjanmahato5390
@rajeevranjanmahato5390 3 жыл бұрын
why Transformer work not in DC 🤔🤔🤔 Samz m to aya par doubt clear ni hua technical language m sir
@ssinghrajput7626
@ssinghrajput7626 3 жыл бұрын
Sumpner test Power factor improve induction rasitance capacitance kaise kiya jata h
@vikashkumargarg9453
@vikashkumargarg9453 Жыл бұрын
IDT me double tap changer kyo lagte he
@a.k8292
@a.k8292 3 жыл бұрын
Sir please waste heat recovery system in cement plant (my 3rd time comment )
@purnasahoo791
@purnasahoo791 3 жыл бұрын
Sir,i have a doubt from long time.i have 2 incomer i/c-1 and i/C-2 ,for a 3phase with neutral connection can i gave 3phase from i/c-1 and neutral from i/c-2.
@AmmadAsim
@AmmadAsim 3 жыл бұрын
No don't do that, use Neutral of that incomer whose phases u r using.
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
No.. use phase and neutral of same incomer.
@purnasahoo791
@purnasahoo791 3 жыл бұрын
@@electricalwithabhishekjoshi which type issue are rise if i use phase from different incomer and neutral from different.
@AmmadAsim
@AmmadAsim 3 жыл бұрын
@@purnasahoo791 then it will not be good for health of machine whose only phases are being used, internal circulating current will flow in that machine like it can be traffo or generator that incomer can be , it will work but it won't be technically good, it will be a jugaar, not recommended. Its same as kundaa like in kundaa they use only phase of utility traffo n Neutral from earth so creates bad impact on that traffo.
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Right..
@madhusahu6826
@madhusahu6826 3 жыл бұрын
Sir What is voltage regulation.? Why it's value is always low
@dineshtusia968
@dineshtusia968 3 жыл бұрын
Electrical devices ke proper operation ho sake & system m secondry volt. Constant bnaa rhe.
@googlymasala5131
@googlymasala5131 3 жыл бұрын
Thank you sir... 🙏🙏🙏
@AnilAutomation
@AnilAutomation 3 жыл бұрын
#anilautomationhindi 🙏
@saylipawar7247
@saylipawar7247 9 ай бұрын
Teping kese nikalte he
@girirajpurohit3804
@girirajpurohit3804 3 жыл бұрын
Sir please electrical drawing reading ki series banaye...
@AnilAutomation
@AnilAutomation 3 жыл бұрын
#anilautomationhindi 👍
@Shyama000
@Shyama000 2 жыл бұрын
kzbin.infoLvvPzRL0J1A?feature=share
@Meditative320
@Meditative320 Жыл бұрын
Sir you are wrong in core type winding concentric winding is done and in shell type winding sandwich winding is done ✅
@yunusbhadarka6006
@yunusbhadarka6006 2 жыл бұрын
Sir more insulation required by High voltage side note low voltage side low voltage side required High counductor note insulation
@pankajyadav2943
@pankajyadav2943 3 жыл бұрын
Bhai discription me link dall dia kr dusri video se related
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Okay Pankaj..
@yashwantchandrakar6391
@yashwantchandrakar6391 9 ай бұрын
Auto transfomer ka video banao na
@chandrapuraccesslovers..3035
@chandrapuraccesslovers..3035 2 жыл бұрын
Transformers kaise band karte hai
@khan_tanzeem0521
@khan_tanzeem0521 3 жыл бұрын
Perfect!!
@AnilAutomation
@AnilAutomation 3 жыл бұрын
#anilautomationhindi 👌
@RishikeshMeena-jv8ff
@RishikeshMeena-jv8ff Ай бұрын
Power transformer tap chengrer secondary winding connect
@RKTECHNICALCLASSES
@RKTECHNICALCLASSES 3 жыл бұрын
Concept of class of insulation just you give for tapechanger on hv winding of transformers is not suitable.
@AjayTiwari-xp1xh
@AjayTiwari-xp1xh 2 ай бұрын
Dg videos h
@abhishekchauhan3522
@abhishekchauhan3522 8 ай бұрын
Oltc trip kyu hota hai reason batayen plz
Transformer Tap Changer | ON Load Tap Changer | Tap Changing Transformer | Tap Changer working
10:06
Transformer Tap Changer| ON Load vs OFF Load Tap Changer| Interview Question | Hindi
8:40
Electrical With Abhishek Joshi
Рет қаралды 35 М.
Sigma baby, you've conquered soap! 😲😮‍💨 LeoNata family #shorts
00:37
Elza love to eat chiken🍗⚡ #dog #pets
00:17
ElzaDog
Рет қаралды 12 МЛН
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 88 МЛН
Osman Kalyoncu Sonu Üzücü Saddest Videos Dream Engine 269 #shorts
00:26
Transformer Tap Changer: On Load Tap Changer Oltc Control Circuit Diagram
14:30
What is Wave Trap| Capacitive Voltage Transformer | Transmission Lines Frequency | Hindi
7:00
Three Phase Transformer: On Load Tap Changer (OLTC) in hindi
14:03
Sourabh Sharma Hindi Channel
Рет қаралды 245 М.
On Load Tap Changer :- How it works?
9:10
sourabh sharma
Рет қаралды 181 М.
Power Transformer - 3D Animation
13:42
LifeAda
Рет қаралды 1 МЛН
Transformer Tap Changer Interview Questions | Electrical Engineering
7:50
Why Transformer Neutral Grounding || electrical interview question
9:41
Electrical Dost
Рет қаралды 605 М.
Sigma baby, you've conquered soap! 😲😮‍💨 LeoNata family #shorts
00:37