Wind Load in Staad ProV8i using Indian code and american code

  Рет қаралды 70,442

Jags 22079

Jags 22079

Күн бұрын

Пікірлер: 112
@bobrobert8684
@bobrobert8684 8 жыл бұрын
Hello Jag,Your video on wind load analysis is very helpful. Thank you very much.Please can I get a complete set of videos on the design of electrical transmission line towers and also that of telecommunication towers using staadprov8i?I will be very grateful if you are able to assist.Thanks in advance.Bob.
@drawingsecoform915
@drawingsecoform915 7 жыл бұрын
thank's for the video, in my structure wind load is not getting applied on the end nodes of the structure( my structure is a complicated design) , can you provide me any advise.
@gajendiranm5740
@gajendiranm5740 5 жыл бұрын
Dear sir did u had wind load manual calculation as per Indian code, can u share that calculations
@harrisashraff
@harrisashraff 8 жыл бұрын
can you do a video on dynamic analysis and non linear analysis of buildings?
@manojkabdwal1838
@manojkabdwal1838 5 жыл бұрын
Please make a video on design of aluminium pergola on staad and also on aluminium bracket and c channel
@Jags22079
@Jags22079 5 жыл бұрын
Ok sure.... kindly like the video to support me
@nandinig5851
@nandinig5851 6 жыл бұрын
Thankq.,. So much sir .,. Your explanation is so understanding .,. Can please explain about taking of moments and shear for tanks ....
@Jags22079
@Jags22079 6 жыл бұрын
Sure ..... and thanks for such a nice feedback 😊😊
@praveenchary2519
@praveenchary2519 5 жыл бұрын
Please vedio on facade design using us , Indian,both stadpro and etabs please
@Jags22079
@Jags22079 5 жыл бұрын
Sure .... like and subscribe to channel for upcoming videos
@drkprasad84
@drkprasad84 8 жыл бұрын
thank you very useful one. I have asked you in earlier vedios for detail explanation on Lx, Ly, Lz and Kx, ky, kz in steel design with a how to use in staff with one example please
@Jags22079
@Jags22079 8 жыл бұрын
thanx bro......I rember... I was a little occupied ........but tomorrow I will post video for that .....stay tuned ....share with friends
@Jags22079
@Jags22079 8 жыл бұрын
bro as per your request i created a video .....here is the link ....... kzbin.info/www/bejne/sGGmdX-waMmKkM0 ..... hope u like it
@BhaveshMestry
@BhaveshMestry 7 жыл бұрын
Jags 22079 hi do you do free Lance work. I have some products I need FeA analysis report with lateral forces and wind force analysis.
@kasturisanjay8993
@kasturisanjay8993 7 жыл бұрын
hello sir actually i have a doubt after taking of concrete design we get different bars in our given property section its okay but i have doubt of when it cum through, lower column indicates less no of bars and upper column indicates higher no of bars and they are in different sizes can i found what the mistake i had done or its propably thats it
@dardarizwan
@dardarizwan 7 жыл бұрын
very helpful video dear .... can u describe different designs according to ACI codes.....specially for buildings
@junjuly779
@junjuly779 8 жыл бұрын
Good Day! i'm just wondering about designing staircases or elevator shafts. Do you have to design them separately from your building structure or do you have to design and analyse them together? Thanx.
@sandipmaru456
@sandipmaru456 6 жыл бұрын
Wind load application on roof and sides from wind definition.
@perumalk3720
@perumalk3720 3 жыл бұрын
Thanks for videos...
@Jags22079
@Jags22079 3 жыл бұрын
Thank you dear… please like and subscribe to support, it really helps me
@sreedevir8663
@sreedevir8663 4 жыл бұрын
Hi, why is Cpe-Cpi not considered in wind intensity manual calculation for IS Code option application in STAAD. Also, why is exposure applied to internal nodes.
@devakirajkumar366
@devakirajkumar366 6 жыл бұрын
nice explanation.. how to put wind load already known or some ideas people's only get easily understood..any way it's easy for me.. thnku..
@goldyakash
@goldyakash 7 жыл бұрын
If i am modelling a cooling tower of ht 150 m according to IS code. Then till what height do i have to give wind pressure intensity manually and in how much ht gaps, to calculate the wind load?
@venkateswarlupittu9442
@venkateswarlupittu9442 5 жыл бұрын
thank you
@Jags22079
@Jags22079 5 жыл бұрын
You are welcome
@pritamdas5658
@pritamdas5658 7 жыл бұрын
please upload a video on design of a concrete structure by applying all load(e.g.- dead,live,wind,seismic,gravity load etc.)
@Jags22079
@Jags22079 7 жыл бұрын
Bro I already have a video for that .....kindly check
@sheenuaggarwal1431
@sheenuaggarwal1431 6 жыл бұрын
How can we apply the load if there is Stair case in Rcc building & how, to calculate it?? Plz upload the video as soon as possible... B'coz bending moment and shear force will change. Then we can prepare the excel file...
@faizanrazakhan131
@faizanrazakhan131 8 жыл бұрын
thank u so much... Jagbir sir
@kishanpurohit5829
@kishanpurohit5829 6 жыл бұрын
Hello Sir, Nice video. Please also upload video on vehicle load calculations.
@BARTLANTV
@BARTLANTV 6 жыл бұрын
kindly upload videos showing design for windloads, earthquake, deadloads, liveloads and the different combination therein.
@bullretailers2212
@bullretailers2212 6 жыл бұрын
please make a video on application of external & internal wind pressure on steel structure.
@muniprasaddiddi8635
@muniprasaddiddi8635 6 жыл бұрын
Is Wind load is possible to apply in cooling tower design in staad pro. cooling tower is in open top & it is an circular shaped. There is no members.
@_Smart_Fusion
@_Smart_Fusion 7 жыл бұрын
Bro I have done as like u did. but think is that after calculating load intensity Pz then how I will calculate intensity for different heights of building ? that I wants to know only
@nagarajutalari8907
@nagarajutalari8907 7 жыл бұрын
nice videos,jags nd can you do the video of strural glazing ,facade design by staddpro
@KunalSharma-wp9wk
@KunalSharma-wp9wk 8 жыл бұрын
That was really helpful,,,Thanks Need to know more about Load Combinations. Define Comb. vs Auto Load Comb., which one to prefer..
@Jags22079
@Jags22079 8 жыл бұрын
thanks bro for your feedback...... for that I will soon post a video with full details...kindly share the video with your friends
@aartichopra124
@aartichopra124 6 жыл бұрын
Sir! The factor you have applied under the wind load, how did you get that factor. why is it 1. why it can't be some other number.
@raedqwareq5735
@raedqwareq5735 5 жыл бұрын
Hello Sir, Can you please help me how can i check exiting 12m telecom tower on rooftop installed on concrete base, also antennas and MW links were installed on this tower. i need to know how can i check if this tower safe or not or if i can installed new equipments on it. please if you have any tutorial please send to me. thx
@roadsidemedia8624
@roadsidemedia8624 6 жыл бұрын
Hi ji...thanks for video lecture. Can you please share wind load calculation excel for warehouse type steel structure factory building
@vemugantisaicharan3994
@vemugantisaicharan3994 5 жыл бұрын
Sir, why were not applying (definations) wind load and sesimic load for analysis. As Code book suggest to take max of both load.does the software doesn't take max of both loads?
@Constructiongyan14
@Constructiongyan14 5 жыл бұрын
We cannot apply at the same time seismic and wind definitions Only one deifinition is possible at the same time in the same buidling.
@vemugantisaicharan3994
@vemugantisaicharan3994 5 жыл бұрын
Then can we apply wind load in load case details??
@rahulpanchal5891
@rahulpanchal5891 7 жыл бұрын
wind load in only one case with same pressure coefficient . Kindly do manual calculation and then put load on members this is the right method can you make video for this with sloping roof (steel)
@sandeep771985
@sandeep771985 4 жыл бұрын
CAN U PLEASE MAKE N SHARE SAME VIDEO FOR SIESMIC LOAD
@Jags22079
@Jags22079 4 жыл бұрын
I already have made 2 videos on Seismic load follow these links for them kzbin.info/www/bejne/Zpa9l5tqdq-Xi9E kzbin.info/www/bejne/jprNo5mcedKYqJI Also check update video for wind load kzbin.info/www/bejne/gIKbe6aFfdh_m5Y Please like the videos when you watch them, it really helps
@farazkhan2564
@farazkhan2564 7 жыл бұрын
Live load are applied using Floor load right 🤔 area load is something we can use to apply for wall load on beam or else if u apply areal load as live load, you have to first calculate the load distribution then apply that way 🤔
@nagendraparida7469
@nagendraparida7469 7 жыл бұрын
can you show a video on curve beam analysis
@dhruvkumar8077
@dhruvkumar8077 7 жыл бұрын
I have calculated Vz value now how to convert it into intensity value. and how to use this converted value in Staad Pro. Thanks Please share as soon as possible
@gamermama3738
@gamermama3738 7 жыл бұрын
u have calculate intensity based on height using is 800 part 3 and then u should put it in staa pro
@bosschidu2891
@bosschidu2891 5 жыл бұрын
Thank you sir
@Jags22079
@Jags22079 5 жыл бұрын
U are welcome ... please like the video to support me
@maulikraval9097
@maulikraval9097 5 жыл бұрын
Pls give suggestions for rebar structure Detailing’s
@prasad1953
@prasad1953 8 жыл бұрын
Nice video sir, can you provide Member releases concept? and Lift load (Elevator loading) procedure? thanks in advance
@waelsaeed3544
@waelsaeed3544 8 жыл бұрын
Thank you very mush - how we can design curtain wall for wind load ( glass and aluminium profile )
@mazharkhan9229
@mazharkhan9229 6 жыл бұрын
one problem I am facing while applying load combination suppose I am applying this load combination 1.2 ( DL +LL-WL) for WL I have use -1.2 factor or 1.2 . according to I should 1.2 because I have already used -1 while giving load .
@MrAshu3253
@MrAshu3253 7 жыл бұрын
hello, please guide, when i place secondary beams on another beam, it creates a node and divide my main beam in 2 part and that usually failed. please guide for placing beams on another beams. and guide when and where to release moments and which moments should be released.
@adithyaroyal6211
@adithyaroyal6211 7 жыл бұрын
CAN WE DESIGN THE STAIR CASES IN STAAD PRO............PLZ UPLOAD A VIDEO ON STAIR CASE
@Jags22079
@Jags22079 7 жыл бұрын
adithya royal dear friend​ I already have 3 videos for staircase design covering different types of staircase like circular and two way kindly follow these links kzbin.info/www/bejne/q3upmY2rlLJqitk kzbin.info/www/bejne/bKKzmmOQaallnNE kzbin.info/www/bejne/lZ_XoZalm9CMpZo there are so many more interesting videos on my channel kindly watch and if u appropriate then please like and share my videos
@lalikanth
@lalikanth 8 жыл бұрын
hello.. I am facing some issue in wind loads fx fy fz command ignored...I need to sort it out this issue with a help of...
@gm-fu1my
@gm-fu1my 5 жыл бұрын
Sir can u explain how to apply wind load on cable stayed bridge
@Jags22079
@Jags22079 5 жыл бұрын
Bro that depends completely on the model
@emadrameez6212
@emadrameez6212 7 жыл бұрын
can you please upload steel structure designs with wind loads using eurocode pls
@sanjaysaxena270
@sanjaysaxena270 7 жыл бұрын
good job keep it up , i have subscribed it
@Jags22079
@Jags22079 7 жыл бұрын
Sanjay Saxena thanks dear
@sanjaysaxena270
@sanjaysaxena270 7 жыл бұрын
pl explain difference where we use area load tab and floor laod tab , while defining loading
@eway2subrata
@eway2subrata 7 жыл бұрын
please show the combination load with wind, dead and live in steel structure design
@soumikdatta2402
@soumikdatta2402 7 жыл бұрын
CAN U UPLOAD A G+3 building with complete details
@Jags22079
@Jags22079 7 жыл бұрын
+Soumik Datta dear friend....Take reference from this video.....If u still have doubts then do let me know..... Please like and share and comments for your feedback
@parmbirsinghgill3603
@parmbirsinghgill3603 5 жыл бұрын
How to check failed members in structure?
@Jags22079
@Jags22079 5 жыл бұрын
I think i shown it in one of my video.... but will mention it in my next video for sure..... subscribe n hit bell icon so that u get notifications..... n please like the video.... it really helps me
@parthvakani4422
@parthvakani4422 3 жыл бұрын
Please make staad report with 0 error 160 kmph wind speed Solar panel ground mount structure wind analysis video
@manaweralistr7182
@manaweralistr7182 5 жыл бұрын
Sir..plz tell me exposure factors..I can't understand properly
@Constructiongyan14
@Constructiongyan14 5 жыл бұрын
Thnqqqqq sir
@Jags22079
@Jags22079 5 жыл бұрын
U are welcome.... kindly like the video
@swamysai-gu6ls
@swamysai-gu6ls 7 жыл бұрын
Can you upload a video by using manual method
@RakeshSingh-ki5in
@RakeshSingh-ki5in 7 жыл бұрын
Hi Sir" how to create steel fabricated box girder in staad pro.
@sreenivasanvasu2595
@sreenivasanvasu2595 5 жыл бұрын
Why were the leeward wind load not accounted for?
@Jags22079
@Jags22079 5 жыл бұрын
Whts leeward wind load
@naveen9262
@naveen9262 6 жыл бұрын
Sir, I like the way of your explanation. I'm Naveen kumar i have done BE civil Engineering and M Tech in Structural Engineering, right now im looking for a job. can you help me sir ?
@Jags22079
@Jags22079 6 жыл бұрын
naveen baabu u can apply in intec infra
@naveen9262
@naveen9262 6 жыл бұрын
thank u sir, but there is no openings for fresher
@deepadubey7488
@deepadubey7488 7 жыл бұрын
i m doing tank design(intz) HOW TO APPLY wind load in tank
@Jags22079
@Jags22079 7 жыл бұрын
Deepa Dubey you can use the same method ...for tank design there are 2 videos on my channel....take reference from them.....and please like and share videos...do let me know in case of help
@Jags22079
@Jags22079 7 жыл бұрын
Deepa Dubey tank design video links. kzbin.info/www/bejne/gJWUgqeOp6yJm8k. kzbin.info/www/bejne/pJrIYpyVmtN6qZo
@Sanjeevkumar-if3kd
@Sanjeevkumar-if3kd 5 жыл бұрын
hlo sir i need some technical help regarding staad pro help me
@rohitdogra5105
@rohitdogra5105 6 жыл бұрын
how to calculate the value of k1 k2 k3 of design wind speed?????
@mudasernazer6657
@mudasernazer6657 5 жыл бұрын
Sir please help on seminar of wind load compare old and new wind load code
@mazharkhan9229
@mazharkhan9229 6 жыл бұрын
I don't doubt your capabilities but I request you to do only wind load analysis as per IS code 875 in stadd pro then show that value of lateral load due to wind which you got from stadd pro is same as that of manual calculation. you have spended 21 minutes I appreciate but this video is not clear. Take it as challenge . I have lot of doubts . let's start healthy discussion . I request you please accept my request
@zionmoses1839
@zionmoses1839 5 жыл бұрын
floating column design on staad pro plzzzzzzzzzzzzzz
@Jags22079
@Jags22079 5 жыл бұрын
Sure i will make a video on that soon
@zionmoses1839
@zionmoses1839 5 жыл бұрын
@@Jags22079 plzzzzzzzz do seismic design analysis of floating columns on saatd pro for which i will be really thankful to you sir
@ManpreetSingh-rm1fn
@ManpreetSingh-rm1fn 5 жыл бұрын
How to change units in structure wizard?
@Constructiongyan14
@Constructiongyan14 5 жыл бұрын
In Top tool baar it is present chnge graphics input units
@sapnac3257
@sapnac3257 5 жыл бұрын
How to manual calculate load
@Jags22079
@Jags22079 5 жыл бұрын
Buy manual calculation of design code
@akshaymalviya702
@akshaymalviya702 7 жыл бұрын
transmission tower wind load
@Life_truth33
@Life_truth33 5 жыл бұрын
What is wind factor
@rohitdogra5105
@rohitdogra5105 6 жыл бұрын
please explain with example
@pankajbehl10
@pankajbehl10 7 жыл бұрын
kindly pls upload video on moving loads
@Jags22079
@Jags22079 7 жыл бұрын
PANKAJ BEHL sure dear I will post very soon.... please like and share my videos with your friends on Facebook and WhatsApp as much as u can....feel free to ask any help
@blackheart2306
@blackheart2306 3 жыл бұрын
Pls show in details
@Jags22079
@Jags22079 3 жыл бұрын
Please watch my latest video on this here......please Like and Subscribe, it really helps me to reach more people kzbin.info/www/bejne/gIKbe6aFfdh_m5Y
@ShuaibVPkarimbanakkal
@ShuaibVPkarimbanakkal 6 жыл бұрын
*** NOTE: If any floor diaphragm is present in the model Wind Load definition why this showing
@ramgirishanmukh4643
@ramgirishanmukh4643 5 жыл бұрын
Haa how
@111111jps2515
@111111jps2515 3 жыл бұрын
Please show warning and solution.
@sonaldhodi8879
@sonaldhodi8879 4 жыл бұрын
Wind load is not understanding easy calculate method said
@Jags22079
@Jags22079 4 жыл бұрын
Did not got your question
@ki84ng
@ki84ng 6 жыл бұрын
your wind load application is incorrect (putting all wind load directions in one load case) please correct it
@steeverthebest
@steeverthebest 4 жыл бұрын
I was wondering about the same thing, so what you mean it should be in 4 direction?
@singampriyokumarmeitei4193
@singampriyokumarmeitei4193 7 жыл бұрын
u can not apply all the direction of wind load under same wind load case. each and every direction say x, -x, z and -z should have different wind load cases. please don not give false information to the beginners.
Generating Wind Loads for Other Structures in STAAD.Pro
17:28
Bentley Structural
Рет қаралды 11 М.
Generating Wind Loads for Building Structures in STAAD.Pro
29:28
Bentley Structural
Рет қаралды 37 М.
Accompanying my daughter to practice dance is so annoying #funny #cute#comedy
00:17
Funny daughter's daily life
Рет қаралды 28 МЛН
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
How Many Balloons To Make A Store Fly?
00:22
MrBeast
Рет қаралды 190 МЛН
Navigating the Post Processor in STAAD.Pro
17:11
Bentley Structural
Рет қаралды 8 М.
Calculation of Wind load  | Design of steel structures and timber | IOE III/II PU MU |
15:22
Parash Joshi - Civil Construction and Tutor
Рет қаралды 57 М.
Generating Static Seismic Loads in STAAD.Pro
17:46
Bentley Structural
Рет қаралды 22 М.
Staad Pro Industrial Warehouse Design ( Steel Design )
20:33
Jags 22079
Рет қаралды 103 М.