Thank you! Was really good to see the actual Ohm readings in your video, as I was initially testing at MOhm range and thought I might have a bad motor on my hands. Also thanks for not making it a 15 minute long lecture!
@marcodevera52413 жыл бұрын
Finally got an english and informative one
@flightworks68744 жыл бұрын
Finally an informative video
@ljboyd134 жыл бұрын
Of course, this doesn't test for insulation breakdown. And you should also discharge the capacitor before touching it.
@davidgithiomikamau6 ай бұрын
Good illustrations
@constantindanieltira3 жыл бұрын
Can you attach a speed limitation on this motor ? Thanks
@naturestrail2296Ай бұрын
I wish they'd describe how to know which wires are which more.
@mostlikelywedoitservices6926 Жыл бұрын
Ohming a motor is not the best way. Megger is much better. I have had motors run fine and ohm fine. But after an hour of running, they start having problems. Megger the windings and immediately motor winding fail due to insulation breaking down. So if you deal with motors, you need to have a megger.