Wood stove shielding

  Рет қаралды 18,627

Border Property Inspections

Border Property Inspections

Күн бұрын

If you have a wood stove that needs significant clearances behind and beside it, you may be able to build a shield that allows you to position the stove closer to the wall. Watch todays video to get a better understanding of the rules around shield a wood stove.

Пікірлер: 28
@dbhunter6798
@dbhunter6798 10 ай бұрын
Great video. Thanks for all the detailed information.
@AjaOBrien
@AjaOBrien 7 ай бұрын
I could kiss you for this! Seriously so helpful, thank you!
@filmongebremeskel6422
@filmongebremeskel6422 3 ай бұрын
Amazing, thank you
@denverbasshead
@denverbasshead 11 ай бұрын
Regulations suck. We just use the stove manufacturers clearences. Most new stoves are like 9inches without shielding
@borderpropertyinspections2634
@borderpropertyinspections2634 11 ай бұрын
I agree, some rules don't bake sense but as an inspector I need to call out even minor infractions. Sometimes miner issues mean the entire install must be redone. If the chimney is older it is likely the entire chimney needs to be replaced. On the other hand, stoves with clearances on the label are tested in a lab and are deemed safe if the clearances are maintained. Problem with wood heat is the heat dries out the nearby components and eventually burst into flames.
@denverbasshead
@denverbasshead 11 ай бұрын
@@borderpropertyinspections2634 I live where there aren't inspections lol, but I get you have to for your job. But I always want to do it right the first time, so double wall stove pipe is a must. Single wall should be discontinued
@HermesTresmegestus
@HermesTresmegestus 10 ай бұрын
I need some real numbers here. What does 67 percent mean? And where exactly does that 67 percent start? Does it start at the front of the combustible wall (drywall) or does it start at the front of the shield? Lets say 18" spacing for non-shielded wall. We then add 2 inches of spacer and heat shield. So the reduction is 67 percent which of 18" is about 12". This means to me that I can now move my stove to the drywall 12 inches. So with the 2 inches of heat shield my stove is now 4" away from the shield. The difference between the thickness of the heat shield and heat clearances I'd like some illumination on
@borderpropertyinspections2634
@borderpropertyinspections2634 10 ай бұрын
Sounds like you have it right. If the stove requires 18" to combustibles (drywall and studs, not Stine etc) and you add a steel shield to gain 67% reduction, now the stove can be 6" from the drywall. The shield should be 7/8" minimum from the combustible wall. The position of the shield and stove is irrelevant. When measuring from stove to combustibles ignore the shield. Hope that helps.
@jerryf609
@jerryf609 Ай бұрын
Thank you. Is this nook available for purchase? Or possibly from a library?
@borderpropertyinspections2634
@borderpropertyinspections2634 Ай бұрын
Only to trained WETT inspectors. Call or text me and I'll help if I can.
@charlos4241
@charlos4241 11 ай бұрын
Very helpful thank you for this infomation. Do you happen to know the handbook for USA, specifically for Texas version?
@borderpropertyinspections2634
@borderpropertyinspections2634 11 ай бұрын
No sorry
@butterflygardener
@butterflygardener Жыл бұрын
I thank you for your video :) It has helped me a lot. I'm also interested in hearth pad clearances. Is it possible to get one of these wood energy technical training reference manuals, digital or otherwise?
@borderpropertyinspections2634
@borderpropertyinspections2634 Жыл бұрын
Your welcome glad it helped . The manual is only available to Wett trained individuals I'm sure
@borderpropertyinspections2634
@borderpropertyinspections2634 Жыл бұрын
Almost all stoves have the dimensions in their manual. If not the standard is 18" from the front of the door lip to the front and or any side with a door. 8" to the sides and back. If the stove has a clearance less then 8 " at the back then the pad much be tight to the wall only.
@borderpropertyinspections2634
@borderpropertyinspections2634 Жыл бұрын
Watch my inspection video
@SistersofIBEW280
@SistersofIBEW280 11 ай бұрын
Is the 7/8" standoff acceptable from drywall covered with paper, or something like cement board?
@borderpropertyinspections2634
@borderpropertyinspections2634 11 ай бұрын
If the wall is shielded with the handful of option then the reductions can be applied. The child MUST be non combustible. Either metal, ceramic tiles, cement board and a few other materials are acceptable
@dmbassett
@dmbassett 5 ай бұрын
These are all USA rules yes? In AU we have different regs…
@borderpropertyinspections2634
@borderpropertyinspections2634 Күн бұрын
Canada
@farmboydavid7596
@farmboydavid7596 Жыл бұрын
What is a good noncombustible meterial to use to create that 7/8” or 1” air gap behind one’s heatshield?
@borderpropertyinspections2634
@borderpropertyinspections2634 Жыл бұрын
Copper pipe couplings work well
@wcswood
@wcswood 11 ай бұрын
I used cut pieces of conduit.
@paulgush
@paulgush 9 ай бұрын
These are the Canadian regs, right?
@borderpropertyinspections2634
@borderpropertyinspections2634 9 ай бұрын
Yes
@nicholaspostlethwaite9554
@nicholaspostlethwaite9554 9 ай бұрын
That is just weird. Most wood burners are put in old fireplaces, exhausting through the original chimney. When first used the open fire itself would be next to the wall. Why is anyone worrying about warm bricks? Oh perhaps as it in not UK these are all wooden houses?
@paulgush
@paulgush 9 ай бұрын
This is for combustible wood framed walls. A lot of stoves in north America get installed in places where there was never a fireplace, like cabins, garages, even living rooms
@borderpropertyinspections2634
@borderpropertyinspections2634 9 ай бұрын
@@paulgush I guess it's all about pyrolysis. when combustible materials such as wood framing is heated over and over again it can ignite at a much lower temperature than normal. If 480° C, 920°F is the normal wood that is super dried by the process of pyrolysis might ignite as low as 120°C or 250°F. Shielding is designed to prevent the wood framing from reaching over 90°C, 194°F.
10 WOOD STOVE MISTAKES That Cost You Money!
20:25
Wranglerstar
Рет қаралды 319 М.
DIY Wood Stove HEARTH in a Mobile Home
7:53
Sow the Land
Рет қаралды 79 М.
Как подписать? 😂 #shorts
00:10
Денис Кукояка
Рет қаралды 8 МЛН
OYUNCAK MİKROFON İLE TRAFİK LAMBASINI DEĞİŞTİRDİ 😱
00:17
Melih Taşçı
Рет қаралды 13 МЛН
Don't look down on anyone#devil  #lilith  #funny  #shorts
00:12
Devil Lilith
Рет қаралды 10 МЛН
Wood Stove Clearances
6:59
Red Feather Development Group
Рет қаралды 21 М.
Home Hints Part 3 Wood stove Inspection
17:29
Border Property Inspections
Рет қаралды 40 М.
Wood Stove Heat Shield-MUST WATCH!
11:43
Everything Homestead
Рет қаралды 39 М.
Wood Burning Stoves for Beginners!
38:07
Gosforth Handyman
Рет қаралды 285 М.
How close can my wood stove be to the wall?
8:54
Life on the 49th
Рет қаралды 37 М.
Why? A cookstove and fireplace in the same kitchen
12:49
the log cabin life style by Jerry Tyson
Рет қаралды 506 М.
How to Build a Wood Stove Hearth - Framing a Hearth
4:44
Phil Crockett
Рет қаралды 228 М.
Does Heating With Firewood ACTUALLY Save You Money?
14:24
Hometown Acres
Рет қаралды 362 М.
DIY Hearth pad, Wall Protection, and Clearance
13:04
Mikaela Garcia
Рет қаралды 53 М.
Installing the Wood Stove
39:56
Live Simple, Live Free
Рет қаралды 410 М.