Brilliant install 👏 great to see someone taking pride in their work! Question, is there any issue with lever valves on a heating side of system? I was told there was but I'd far rather use lever valves as they seem much more reliable to me than gate valves. Just wondering do you need specific brand or is it just wrong information I've been told? Keep up the great work 🙌🙌
@raheatingservices6522 жыл бұрын
Much prefer lever valves over gate valves! There’s no issue on a system boiler with lever valves. If it was a regular boiler then that’s a different matter as you could isolate the boiler from the F and E tank. Plus if the valves failed then it would mean the regular boiler would be pressurised.
@StonesPlumbingandGas2 жыл бұрын
There’s no reason why you couldn’t use lever valves instead of gate valves on any heating system. The only exception to this (I believe) would be for a bypass, where fine adjustments are necessary and the gate valve mechanism is far better suited.
@raheatingservices6522 жыл бұрын
It was a complete pleasure to work with Hartley Heating and Plumbing on the installation. The wiring to the boiler was completed by myself. Normally with an Unvented cylinder installation you would use a 2 port valve and use the safety limit stat to shut the heat off the heat source. With the integral diverter valve kit you achieve this by wiring the safety limit stat direct into the boiler. The Installation and service instructions detail what’s required with the wiring.
@raheatingservices6522 жыл бұрын
The cylinder sensor is wired into the boiler direct, so the boiler monitors the temperature of the cylinder. The safety limit thermostat is wired in to the live of the boiler so in the effect the cylinder overheats the boiler shuts off. Similar principle to a safety cut out on a condense pump and overfill on that.
@harryblack60022 жыл бұрын
So glad you’ve wrote this . Just tried looking for some MI’s on integral Diverter and cannot find them lol
@raheatingservices6522 жыл бұрын
@@harryblack6002 yes, it’s in the Worcester bosch cylinder instructions glad to of helped
@fixedc2790 Жыл бұрын
@@raheatingservices652 What controls the hot water, is it the boiler just as and when according to the cylinder sensor? There's no switched demand on the hot water side so it must be "always on". What if the customer wants time control for hot water?
@imranyaqub17902 жыл бұрын
Rate your workmanship Better than outstanding. Had a similar WB8000 system boiler and tank fitted at my parents place last year, our plumber was also very clean and tidy with the pipework, but you've take the job to a new level. Wish you could do the plumbing work at my place. Best of success with your work 👍
@ernestbhatti10302 жыл бұрын
Mate your plumbing is a work of art. I would happily ditch the tv and have that in the lounge and just watch that instead.
@jonathanlanglois27422 жыл бұрын
I really like the look of that pipework. Those clamps look great. You obviously take a lot of pride in your work. That is so much cleaner than most of what you would see in a North American home. Then again, we generally don't have anywhere near that much pipework. Just a hot water boiler and that's about it. Almost all homes in Québec are heated with electric systems. In other jurisdictions, gas is more prevalent, and that's generally completely separated from the hot water system.
@dreamkiss Жыл бұрын
One thing I would love to see is a schematic diagram with integral diverter valve. Nothing on the Internet
@loving-plumbing2 жыл бұрын
Excellent install. Never knew about that diverter valve set up. Pretty awesome
@hartleyheatingandplumbing98012 жыл бұрын
Thank you matey !!
@CommercialGasEngineerVideos2 жыл бұрын
This is a nice channel. Looking forward to seeing more videos. Excellent plumbing, good camera work and editing.
@samjohnson53162 жыл бұрын
Great work as always. From one plumber to another. One thing to comment on. The bypass setup is after the magnetic filter so won’t that slow flow water into the boiler after the filter?? Just a thought. But always easier to pic at things after the job is done. Still great to watch
@michaelstaley22412 жыл бұрын
Very professional looking job excellently delivered.
@campbellcopeland2 жыл бұрын
Looks superb - I've got a very similar (but previous generation) system but with the Greenstar 30CDi Classic System & Greenstore SC210 with a Wave controller, filter and the optional Integral Diverter all installed 7+ years ago and still like new. Not as neat and tidy as this one though!
@michaelstaley224111 ай бұрын
Excellent man top class job very tidy amazing pipe work.👍🏻
@dazl79542 жыл бұрын
Extremely neat and tidy instal fantastic pipework, Nice to see Rich doing some actual work :) well eating lol (double check his wiring tho) if he see's this, he should twig who I am :). look fwd to the next vid.
@raheatingservices6522 жыл бұрын
My wiring has improved some what, I hope you are well! I’ve twigged don’t worry 👍🏻
@dazl79542 жыл бұрын
@@raheatingservices652 your experience grows :-) and shows in the job shown. glad ya twigged. Bet he did not lift the 400 out like he did the 8000 in 😜
@raheatingservices6522 жыл бұрын
400 on a sack truck! I’m sure you were pleased to see the back of those boilers! Nightmare especially with the plate heat exchangers!
@dazl79542 жыл бұрын
@@raheatingservices652 pls stop, I will have nightmares :) but true.
@mistaceali1177 Жыл бұрын
Simply wow mate, what an amazing install 👌🏽
@daljitsingh5492 жыл бұрын
Beautiful pipe work, very neat and tidy. Top job.
@hartleyheatingandplumbing98012 жыл бұрын
Thanks for the kind words !
@staniforth772 жыл бұрын
Awesome job mate! Pipework is A+ 👌
@MJTiffPlumbing2 жыл бұрын
Cracking work as always Will......and great to see you back on YT, keep the content coming buddy
@hartleyheatingandplumbing98012 жыл бұрын
Thanks pal !!! 🤝
@scottpenman2962 жыл бұрын
Mind fit wee green umbrella above diverter 👍
@Caffro2 жыл бұрын
Really impressed as I’m a gas engineer and learn something new today when he bends the pipe with water and it never seen that done Great idea makes perfect sense enjoy the video👍
@hartleyheatingandplumbing98012 жыл бұрын
Thank you !! Great trick that is to create a perfect bend from the pressure relief
@aminsajawal39352 жыл бұрын
The reviews says it all brother. Top man 👍🏻
@hartleyheatingandplumbing98012 жыл бұрын
Thank you so much !!
@Tom_Plumb_PHS2 жыл бұрын
Very nice work. Found your channel through Allen Hart. Subscribed now. 😊 Nice to see silver, I'm not keen on black backings, look nice but make dark small cupboards even darker for the next guy.
@adaesco2 жыл бұрын
Whats the reason for the internal divertor kit? Cant find any info online. Lovely install btw
@gregchapman55562 жыл бұрын
That’s a bloody work of art 👏👏.
@capnZA5 ай бұрын
Am I correct in understanding this means you can set a different hot water and CH temp on the boiler? And it heats according to which call it gets from the controller?
@JeffersonHumber2 жыл бұрын
That should be on display at the Louvre 👍🏻
@valentintrapkevic44964 ай бұрын
Can you set a different flow temperature for the radiators and cylinder with this diverter setup? thanks
@steviemaclennan12922 жыл бұрын
Very nice work 😀, as good as I've ever seen to be honest....subscribed👍 Looked like stuffing gland is missing from tank stat
@raheatingservices6522 жыл бұрын
Stuffing gland? There’s the cylinder sensor which was installed into the pocket onto the cylinder.
@allanstewartseo Жыл бұрын
Hi, brill install! Well done. Just wondering why client didn't get the worster controller as the nest doesn't do weather compensation modulation only on/off?
@AllenHart9992 жыл бұрын
Amazing work.
@hartleyheatingandplumbing98012 жыл бұрын
Thanks Allen !!
@AllenHart9992 жыл бұрын
@@hartleyheatingandplumbing9801 I have shared your videos across some of my channels. Hope it helps 👍
@raheatingservices6522 жыл бұрын
Thank you Allan as I’m in the video as well assisting with the wiring
@hartleyheatingandplumbing98012 жыл бұрын
That is extremely kind Allen !! I’m 25 and trying to grow the businesses my Dad recently retired from so I really appreciate it
@AllenHart9992 жыл бұрын
@@hartleyheatingandplumbing9801 I have also subscribed so I will share every video you upload. It’s amazing to see such good quality in our industry. Thanks for sharing and good luck
@madmatt1139442 жыл бұрын
Beautiful work, what are your thoughts about unions to the manifolds that are on the tank? Ya know one day when it needs to be replaced or serviced. It would be a shame to have to get the torch back out.
@dreamkiss Жыл бұрын
Where have you plugged the integral diverter value NTC sensor? is this plugged into the same dry pocket as the dual thermostat?
@Falco45able2 жыл бұрын
Awesome a credit too your trade fella, stay lucky,stay safe !😉
@alfypierri80222 жыл бұрын
Really enjoyed your video. What panels did you use to hand the boiler. ?
@pradhpatle2 жыл бұрын
👌great install. Couple of questions though. 1. Why feeding coils in parallel and not loop in loop out. 2. Why not use Worcester controls through EMS so as to achieve load compensation and or weather compensation. Asking to get different perspective and not to be picky.
@raheatingservices6522 жыл бұрын
Personal preference to load/weather compensation. I would say most end users are not used to low flow temperature going around the heating circuit. When I was in technical support for WB most common queries we got was on the FW100 weather comp control. Common complaint was the radiators were cool when it was colder outside we had a set of instructions to maximise flow temp from the boiler. We normally advised after the call to get in touch with the installer and to have it removed.
@pradhpatle2 жыл бұрын
@@raheatingservices652 I agree so after few early installs I switched back to load compensation which has worked fine. My learning was if anyone want to time the heating than weather comp no good. But for continuous heating it works brilliantly. My own house I have only weather comp(advance weather comp) and no thermostat and it works perfectly fine.
@warrenwebb2105 Жыл бұрын
I have the same system just few years Older How do you wire in hive .. ?
@mgbroadsterJ Жыл бұрын
How does the diverter handle mumtible circuits and what temp are you feeding the hot flow ?
@StonesPlumbingandGas2 жыл бұрын
Quality work mate, was a pleasure to see how you work and pick up some tips. Nice one. Looking forward to the next one 😁🤩
@hartleyheatingandplumbing98012 жыл бұрын
Thank you very much Sam !!
@PlumbLikeTom2 жыл бұрын
That's a superb install mate, really nice work
@hartleyheatingandplumbing98012 жыл бұрын
Thank you Tom !!
@warrenwebb2105 Жыл бұрын
Plz help I have a diverter valve fitted to my system boiler but nobody can wire it to the hive .. any help
@davidrobbins94012 жыл бұрын
Outstanding pipe work 👍👌👌
@mgbroadsterJ Жыл бұрын
Can you only use the diverter kit when using a Worcester cylinder? Is this system PDHW ?
@paulsimpson22322 жыл бұрын
What's the purpose of the big cylinder ? Please
@joncoke82082 жыл бұрын
Top job that mate any benefits linking the solar?
@B1cam2 жыл бұрын
Hi thanks for posting. Really nice work. Can I ask? It looked like you fitted a isolation valve between the (combined pressure reducing/pressure release valve,pressure vessels) and the cylinder on the cold water pipe. My understanding is there should be no way of isolating between the cylinder and the safety devices . The only fail safe would be the TPRV. It was hard to see from the video. Is that what was done and is it against regulations or manufactures instruction? No hate just though it’s a distinction worth making. 👍🏼
@nevillethumbcatch56912 жыл бұрын
Not hating on the install as its a very neat bit of pipework, but the valve shouldnt be there. To avoid the need to drain off the cylinder i personally take the CWCV above the top of the cylinder , it then requires minimum draining for servicing or replacing.
@elwittinio28652 жыл бұрын
@@nevillethumbcatch5691 Ditto, it's not high enough. Should not have a valve after combination valve either.
@Gutter-Snipe2 жыл бұрын
excellent plumbing work. Personally i have not found any wall hung boiler that has any good longevity, what are your thoughts?
@raheatingservices6522 жыл бұрын
Depends on the wall hung boiler, things like the Ideal Classics, Baxi Solo’s are still going strong. I know Worcester Bosch endurance test products and can last up to 25 years.
@markworthington38932 жыл бұрын
Lovely install 👍🏻
@johnridley16562 жыл бұрын
That is nice and neat, but ive never seen a bypass valve fitted so soon in the loop.
@shafaqathussain86772 жыл бұрын
Great work how long did it take you to complete the job 👍
@randomcamerajunk69772 жыл бұрын
I'd give it a 7/10. You can have 10/10 if you tell me you used weather comp (nest doesn't count unless you're running opentherm), upgraded the the TRVs to pressure independent, mapped the pump to match the index circuit, got the rads running at a nice low MWT to take maximum advantage of the lovely PDHW you installed and covered your nice shiny pipes in the thickest lagging you could find.
@nemanjagradinac54192 жыл бұрын
Hi mate, are you running this on low temp flow (55°C)? And if so how are you controlling the multiple zones?
@fixedc2790 Жыл бұрын
I dont think theres a way you can have different flow temps on more than 1 heating zones, obviously the dhw takes priority and must fire at full rate, you can then weather comp all heating zones but not differentiate them as far as i'm aware
@thomasgoodman38762 жыл бұрын
looks great nice pipes, silver musons 🤩
@hartleyheatingandplumbing98012 жыл бұрын
Thank you !!!
@mgbroadsterJ Жыл бұрын
Do you need a sensor on the cyinder for PDHW ?
@crplumbing27462 жыл бұрын
Brilliant install mate and the work into it amazing end product 😍😍🔥💥
@hartleyheatingandplumbing98012 жыл бұрын
Cheers brother !
@mgbroadsterJ Жыл бұрын
Can use any unvented cylinder ?
@mohammednazir83072 жыл бұрын
Enjoyed watching you video. Keep up the good work. Question: Didn't you do the electrics yourself? Did u get a sparky do that side of the job.
@raheatingservices6522 жыл бұрын
Hi Mohammed, I did the electrics to the boiler myself. I’m another heating engineer that understands the electrical side of this installation that Hartley Heating and Plumbing didn’t feel the sparky would fully understand the set up with the Nest, Cylinder, integral diverter valve etc
@karlschoen72972 жыл бұрын
Nice clean job 👍
@gregdempster5062 жыл бұрын
Proper Class install mate! Love the touch with the silver paint 🤌 one thing...your waste pipework for the D2, is that high temp pipe? I was of the understanding that d2 from a cylinder can discharge into 1" 1/2 but the waste pipe must be high temperature pipe...please correct me if I'm wrong though!
@hartleyheatingandplumbing98012 жыл бұрын
Thanks for the kind words !! Yes Mcalpine can be used now as it’s rated for the temp
@gregdempster5062 жыл бұрын
@@hartleyheatingandplumbing9801 sweet I will remember that pal 👍
@ML-lg4ky2 жыл бұрын
I wish more plumbers took pride in their work like you do!
@MarkJones-kd6ye2 жыл бұрын
it's more about the price people are willing to pay on the standard of work this guy's job is amazing but bet it cost a small mortgage
@hartleyheatingandplumbing98012 жыл бұрын
Thanks Mike !!
@hartleyheatingandplumbing98012 жыл бұрын
Hi Mark Your right not many people want to pay for this but was lucky enough to spend some hours here
@charliewillis85272 жыл бұрын
Yes that is the problem spraying pipes etc all takes more time and most people don't appreciate all that .I do the best I can with the time and use the benders as much as I can to get a nice neat job
@MAHeating8 ай бұрын
Good job 👍
@moorefyre93812 жыл бұрын
Wow ain't seen you on here for a while nice work hope all is well.
@hartleyheatingandplumbing98012 жыл бұрын
Thank you !! Back with even better content
@ashcowell58022 жыл бұрын
Great job
@jamesfortune51192 жыл бұрын
Very smart great work 👍🏻
@hartleyheatingandplumbing98012 жыл бұрын
Thank you !!
@heatpump85662 жыл бұрын
Great install that
@duncancox49052 жыл бұрын
Today job mate just found the Chanel 👍🏻 new sub 👌🏻
@hartleyheatingandplumbing98012 жыл бұрын
Thanks Duncan !!!
@Loucas2 жыл бұрын
Very nice job!
@WEYHARRY12 жыл бұрын
You still need a 2 port fitting as well as the integral valve, safety valve
@hartleyheatingandplumbing98012 жыл бұрын
Why’s this Harry ?
@raheatingservices6522 жыл бұрын
You don’t need a 2 port, as it states in the Worcester bosch cylinder instructions for the cylinder. You need to be able to shut down the heat source we achieved this by wiring the safety limit cut out direct into the boiler. Standard unvented installation yes, 2 Port and safety cut out required.
@adamgroves28112 жыл бұрын
Brilliant job!
@hartleyheatingandplumbing98012 жыл бұрын
Thanks Adam !
@PlumbingDoctors2 жыл бұрын
Top job 👍🏼🔥
@garrysgaragebuilds2 жыл бұрын
Master piece!!
@bozydarwiechowski69542 жыл бұрын
Nice clean job. The coil should be connected in series and not in parallel, you lose about 30% efficiency.
@swaterman082 жыл бұрын
i bet you can spray some rattle can clear coat onto the pipes to keep them looking fresh
@daleatkinson79012 жыл бұрын
Awesome 👏🏻
@deanholloway77552 жыл бұрын
Lovely work, I think it's a shame too put that behind a door 😁.
@hartleyheatingandplumbing98012 жыл бұрын
Thank you Dean !!
@k20aa2 жыл бұрын
It will be a shame when that lot gets lagged great job
@hartleyheatingandplumbing98012 жыл бұрын
It is indeed !
@huyongquan65542 жыл бұрын
So you add integral Diverter valve to avoid 2 port valve, whether it is good choice depend on what type it was, if with hot water cylinder 2 pipes( flow and return), I don’t think it is good idea. Traditional system(2 pipe) is perfect.
@pradhpatle2 жыл бұрын
Boiler needs to behave differently when doing heating vs hot water. For heating a lower or variable temp is ideal and for hot water you want high temp. With this you do priority hot water and play with multiple control options on heating side to create better comfort and efficiency. You can do the same with traditional s plan system as well with using Worcester wiring control box but this is much easier in single zone applications.
@raheatingservices6522 жыл бұрын
Depends on your application, if it was an existing cylinder which was vented in an airing cupboard boiler in the kitchen and you go for Unvented you wouldn’t run extra pipework between the boiler and cylinder. If it was a new installation then this would be a viable option. Another scenario would be if was a gravity cylinder (2 pipes to cylinder and 2 pipes from boiler to the pump and heating circuit) you could do this integral diverter valve set up.
@thementalgasman3tgasmainte3172 жыл бұрын
Hey lads that’s a neat install 🔥is this Worcester’s way of doing PDHW? Or can the diverter go to mid position ? Not that you’d want it to go mid Position as PDHW is the way forward
@raheatingservices6522 жыл бұрын
The diverter motor they use is the same one they use in the combination boilers. So the motor doesn’t go into mid position. It will favour hot water as that’s the shortest demand if it has a choice of heating and hot water. Hope this helps 👍🏻
@beni46632 жыл бұрын
Go on son!! Love it 👌👍
@hartleyheatingandplumbing98012 жыл бұрын
Thank you !!
@alemgas2 жыл бұрын
Do you get a woman in to polish the pipes before fitting.?? Nice job mate
@umarhussain85432 жыл бұрын
If its a system boiler how come it's got a hot and cold feed from the boiler ?
@hartleyheatingandplumbing98012 жыл бұрын
Hi Umar at the start of the video you can see the diverter valve being fitted this is how it fed the cylinder
@raheatingservices6522 жыл бұрын
Boiler has a cylinder flow and return. Central heating flow and return. The integral diverter valve operates the same way it does on the Greenstar combination boilers. When the arm is fully up it’s in hot water/heating the cylinder. Down central heating. It works on the return so shuts off the pathways to either the cylinder return or heating return. Hope this helps Umar 👌🏻
@alanblackmore83752 жыл бұрын
Never use Map gas on small joints it’s to hot for soldering . Propane only
@hartleyheatingandplumbing98012 жыл бұрын
I love it because of the higher temp when soldering haven’t had any issues through burning ply behind or walls
@thomasschafer72682 жыл бұрын
What is it? A heating pipe Labyrinth? How did you the air out of the system. Look at german heating installation.🙈🙈🙈🙈😂😂😂😂😂