Hi! I connected ma2 to wyw, but wen I choose universes in table I have only one DMX out. Can you hlp me?
@mikeplaysdrums62493 жыл бұрын
Does MA2 parameter count come into play with the Wyg connection? If I have a MA2 command wing with 2048 parameters, can I previz my 6000 parameter show?
@RamanujDeka3 жыл бұрын
Yes, you can. And, there is no parameter limit to MA2 when connecting to WYSIWYG. In fact, I am visualizing a 25000 parameter show.
@jakehues3 жыл бұрын
Which version of wysiwyg do i need? Report, Design or Perform?
@RamanujDeka2 жыл бұрын
Perform!
@panpot60872 жыл бұрын
Where can I find grandMA - WYSIWYG Driver?
@RamanujDeka2 жыл бұрын
Hi, you can download it from the MA Lighting website.
@MaxLindbom3 жыл бұрын
Dose not conect for me what am i doing wrong?
@RamanujDeka3 жыл бұрын
Check if WYSIWYG is set to 'ON' in MA2 under Global Settings. Check the MA-Net Session IP. Check the Session ID in the WYSIWYG Driver. In Device Manager (WYSIWYG) Check the Grand MA2 Properties panel and put in the right Address/Name.
@ЕгорБудкин-х1цАй бұрын
Same. Doesnt work. Everything correct, but wysiwyg dont see the Console.
@ekrobiserver67322 жыл бұрын
Where do i find the Grandma wysiwyg driver ?
@RamanujDeka2 жыл бұрын
On MA Lighting's site in downloads.
@Rmelkar-o9e3 жыл бұрын
Do I need phisical console connected to pc ?
@RamanujDeka3 жыл бұрын
No you don't! MA2 OnPC has parameters unlocked to work with WYSIWYG. If you wish to connect through any other protocol for DMX such has ArtNET, you will need MA hardware to unlock your Parameters.