Very clear and straight forward explanation! Number one on KZbin!
@boilerstobathrooms62673 жыл бұрын
Thank you for your feedback, really appreciate it and I’m glad you liked it 👍🏻 head over to my Instagram page for more content 👍🏻
@Ggxrd1235 ай бұрын
By far you explained it the best
@garyc94453 жыл бұрын
You've just served up the best explained education lesson I've ever come across, been almost 20 years in the education system and have never had anything explained so clearly as this video has done, well done Sir and Thank you so much
@boilerstobathrooms62673 жыл бұрын
Thank you so much for this comment, I love feedback and this made filming this worth while 🙏🏻
@coreplumbinggasltd195011 ай бұрын
I beg to second. I have seen alot of videos and this is second to none. I felt this instant connection that got me engaged. Thank you.
@yosephgeorgiou43692 жыл бұрын
Thanks bud, don't really bother with commenting on KZbin but this is exactly the video I been looking for just the right amount of everything ie: detail for my Brain digest , brilliant start off for me I been doing breakdowns for two years now and I have got pretty good but when it comes to wiring that's my weakness and have to make a educated guess from symptoms or have to call a friend to help me out but this video has helped me alot and put me on the path to strengthen my knowledge , thanks again honesty
@boilerstobathrooms62672 жыл бұрын
Thank you for your feedback that’s great news I’m glad it’s helped you 🙏🏻 got a video coming soon on a S plan fault finding 👍🏻
@hash1339 Жыл бұрын
One of best video and best video in the entire KZbin. Welldone 👏👏👏
@waynenixon7292 жыл бұрын
Great to see that you have used the earth wire correctly! No using it as a switch wire or not having one in the cable. You might already now.... **The earth wire protects the cable!** If mr/mrs DiYer chopped through or put a nail into one of the cables, if there was no continuity back to the FCU fused connection Unit ( 3 amp fuse) then continuity through the buildings wiring back to the fuse board ( Consumer Unit) there would not be enough fault current to earth (through the earth wire) to blow / trip the fuse / mcb and mr/mrs DIYer would receive a very nasty possibly fatal electric shock. If the installation was protected by a RCD Residual Current Device it would cut the power with in 20/30ms (very fast) and save you from receiving the shock, but older installations do not always have this fitted.
@danehowells7502 Жыл бұрын
You make it so easy man I appreciate these videos a lot.
@rabiebhoy924 Жыл бұрын
love this explanation of what I used to consider as my last port of call during fault analysis... its now my go to - thank you
@martineaglen3 жыл бұрын
Great advice. All homeowners should read this (and a few fiiters too lol!). Thank you for de-bunking a central heating electrical system. Cheers!
@boilerstobathrooms62673 жыл бұрын
No problem glad it helped 🙏🏻
@johnabiodun55403 жыл бұрын
Best video EVER! Well delivered and easy to understand. Good job 👏
@boilerstobathrooms62672 жыл бұрын
Thanks for the feedback
@forreal87042 жыл бұрын
❤ thank you for taking the time to do this video. Nice slow breakdown
@terrydavis97132 жыл бұрын
Couldn't agree more with Gary C. Thank you so much
@boilerstobathrooms62672 жыл бұрын
Thanks for your feedback much appreciated
@manjsingh65003 жыл бұрын
Absolutely brilliant. Best explanation enjoyed.
@boilerstobathrooms62673 жыл бұрын
Thank you for your feedback hope it helped
@fruityginger5528 ай бұрын
You should do some teaching series - excellent, precise and very helpful! Thanks u
@Tonynewman1003 жыл бұрын
Great video that’s the second wiring video of yours iv watched first was on Instagram and I can’t believe how much iv learnt your videos are brilliant so easy to follow and understand, breakdowns will be so much easier now thanks you and keep the great videos coming 10 out of 10
@boilerstobathrooms62673 жыл бұрын
Thank you so much for the great feedback, really appreciate this 🙏🏻
@vladimirstafasani46302 жыл бұрын
That’s a great video very clear and concise thoroughly enjoyed it. Well done 👏👏👏
@boilerstobathrooms62672 жыл бұрын
Thanks for your comment really appreciate the feedback
@juniorstokes272 жыл бұрын
This clears up alot man! I cant i believe i didnt come across this sooner. Also just a quick question, what wires are at the bottom? Is it fused spur, pump and boiler wiring? And the roomstat?
@rehanzafar93515 ай бұрын
Thanks for the video much appreciated one question on room thermostat which number is live and switch live 3 or 1 please let me know thanks
@alfypierri80223 жыл бұрын
Best ever video explained. Thank you
@boilerstobathrooms62673 жыл бұрын
Thank you for your feedback really appreciate it
@arianxhebraj6107 Жыл бұрын
You are a Genius and thank you for the BREAKDOWN BIBLE BOOK
@rohanieat Жыл бұрын
Thank you so much for this video mate. Really helped with fault finding. Btw which brand tester are you using?
@abdulseaforth69307 күн бұрын
Re. wiring of the 10 way is usually done by the plumber- no?
@paulhealey298422 сағат бұрын
Can you tell me why my boiler keeps short cyling while heating the water in the cylinder please? Its anew thermostat, and heat exchanger has just been cleaned. Brand new pump too. The cylinder takes one hour from cold to get to 52 degrees. Thanks.
@saamanneriman12942 жыл бұрын
Great video. I have an issue I can’t get my head round. The programmer is on and the hot water side powers up as it should as per the times set on the programmer. On the other hand when the central heating is supposed to kick in as per the times set in the programmer ( eg 7am), nothing kicks in. The only way I can get the central heating to turn on and off is by controlling it with the thermostat dial. What do you think the problem might be?
@faridratni67993 жыл бұрын
Very good video Thanks, I was struggling but after this video I am ok with it
@boilerstobathrooms62673 жыл бұрын
Thank you for your feedback, glad this helped, head over to my Instagram page for more content. I will look into doing an S plan video 👍🏻
@hash1339 Жыл бұрын
Hi Gary what voltage tester you using mate
@gibsonholmes52952 жыл бұрын
I'm a 92+year old motor mechanic with hot water probs on my ST6400CH WITH THE FACEPLATE of ST9400C I HAVE NO HOT WATER TODAY. COMMENT ..i CAN NEARLY UNDERSTAND YOUR EXPLANATION, WHICH I I THINK IS BRILLIANT. i WILL JUST HAVE TO CALL MY CH ENGINEER. BUT THANKS
@lettsc Жыл бұрын
Hi. I have a oil boiler with pump doing working as a system boiler. What’s the best way to link up a time clock and a stat. Thanks
@reliabill872 жыл бұрын
This is such an amazing video, have you got one for s plan?
@boilerstobathrooms62672 жыл бұрын
Thanks mate and yeah search my videos and there is one on here. Also have a lot of helpful content on my insta page
@gretamurray403 жыл бұрын
Thanks for explaining everything so well.
@boilerstobathrooms62673 жыл бұрын
Thanks for your feedback really do appreciate it
@Benji-gq9gx5 ай бұрын
If the programmer was faulty and you put a link wire between live and hot water I'm guessing that would mean the three port valve would be constantly open in the heating position so customer wouldn't be able to get hw? Because the valve wouldn't be in mid position ever?
@sheriefgerges77892 жыл бұрын
All I can say brilliant, most tricks on hw is off ( grey was confuse me alot ) great explanation
@DRJMF13 жыл бұрын
I have a Honeywell controller ST6400C1003 controller box fitted to a 14/19cBi Worcester boiler. The boiler and central heating run only when the controller is by passed is when the black hot water on cable is connected directly to the red hot water off cable, terminals 1 and 4. Anything you can suggest please? I have tried two controller boxes, both could be faulty but unsure how to test them.
@boilerstobathrooms62673 жыл бұрын
Get a Honeywell st4900c instead it’s a 7 day twin channel programmer.
@DRJMF13 жыл бұрын
Thanks, will consider that. I only run the central heating for 1 hr when nights are cold., so I don’t need a programmable controller. Is there a simple switch option instead ? Thank you.
@ukvipsat2 жыл бұрын
Very good video.
@boilerstobathrooms62672 жыл бұрын
Thnk you hope it helps
@train4905 Жыл бұрын
Most exellent sir,thanku
@beggersu3 жыл бұрын
Excellent video mate, thanks
@boilerstobathrooms62673 жыл бұрын
Thank you hope it was helpful
@44Celt Жыл бұрын
My Hwell ST699 programmer doesn't trip on the timer ,but if I turn the spurred switch off/on it trips and runs. It might run the whole time or only 10mins or so [ but trips on if I turn the spur off/on again] Any ideas? Could the internal battery need replacing? Any ideas appreciated before I fork out for a plumber/electrician/new programmer etc
@thelawdisorderchannel Жыл бұрын
Love this video thank you so much brother
@michaelwalsh46089 ай бұрын
Great video
@barrydoherty6363 жыл бұрын
Great video, well done.
@boilerstobathrooms62673 жыл бұрын
Thank you really appreciate the feedback
@ashvanbro93292 жыл бұрын
Best video I have seen mate if possible can you try and do one with a serviceplus s17r
@abdulh633 жыл бұрын
Great explanation!
@boilerstobathrooms62673 жыл бұрын
Thanks for your feedback 🙏🏻
@ImranKhan-cf8gs3 жыл бұрын
Brilliant explanation
@boilerstobathrooms62673 жыл бұрын
Thank you for your feedback
@jockster55252 жыл бұрын
Good effort 👍
@boilerstobathrooms62672 жыл бұрын
Thanks for your feedback
@faridratni67993 жыл бұрын
Please can you do video about S plan please
@mardrix80702 жыл бұрын
I have a Vaillant ecotec 428 with a y plan system.I have 5 wires from the boiler.Live.Neutral and Earth then a black and grey wire which must be switch live and pump live but how do you find out which is which?
@boilerstobathrooms62672 жыл бұрын
Check the boiler wiring diagram as this will tell you what goes where
@user-yh4kl3hx2o3 жыл бұрын
You absolute legend
@boilerstobathrooms62673 жыл бұрын
Thank you hope it helped 🙏🏻
@davidproctor63593 жыл бұрын
brill for revising. thanks
@boilerstobathrooms62673 жыл бұрын
Glad it helped, thanks for the feedback 🙏🏻
@eyyubgasimov22042 жыл бұрын
Very well done !
@boilerstobathrooms62672 жыл бұрын
Thank you for your feedback
@paulrossiter95673 жыл бұрын
Like your style 👍
@boilerstobathrooms62673 жыл бұрын
Thank you
@Carl-re6zb2 жыл бұрын
thanks for the upload.. is it fair to say that if the programmer for dhw is off, 240v will be present up to the cylinder stat off , thus also 240 at the grey of the 3 port??. Therefore, the only way for for no voltage to the grey on the 3 port is for the programmer to be on for dhw??
@boilerstobathrooms62672 жыл бұрын
Yes mate that’s spot on
@twentycm2 жыл бұрын
I am sure you never came across any faults otherwise you would not keep checking the Live again Earth cable, have you heard of missing Neutral???
@CommercialGasEngineerVideos3 жыл бұрын
Love the channel. SUBSCRIBE & LIKE people. I have a question for you on a y-plan error I gave up on. No 230v to the white wire when calling for hw and ch on sundial wiring center. Programmer was sending 230v to ch on and hw on. I suspected that it might be the wireless room stat (although I did test it). Who knows, they are gonna have tive with it.
@antoniogalluccio42138 күн бұрын
If instead of the link you just manually rearm the zone valve