The amplitude on the charts at the beginning of the video may be incorrect. I believe that 240V mains is 240V RMS (in the USA at least).
@ImpracticalMachinist3 жыл бұрын
Yes that’s true, the charts are a simplification in that respect. While it might have been an interesting aside, the graphs are really just supposed to be an illustration of what is going on even if they’re not strictly accurate, it may have been confusing to say that the peak is 300-odd volts when we’re using 240v for programming the vfd.
@dronesvisionsaeriennes9 күн бұрын
Hello, nice video but on my side I am under FluidNc and despite the 10v/Gnd and Fwd/Rev connections I can't start/stop my spindle on my VDF YL620...I have P00.01=1 and P07.08=3...do you have any idea? Thanks..Philippe
@StevePotter4 жыл бұрын
Looking forward to the next video with installation and testing. Thanks for the extra files!
@ImpracticalMachinist4 жыл бұрын
Hopefully that'll be done soon. I was aiming for today but it's been quite a busy week.
@levelone12342 жыл бұрын
I am trying to hook this up to a commercial washing machine. It runs the machines, counts the quarters- but then resets and the machine doesn't start. Any help would be appreciated
@ImpracticalMachinist2 жыл бұрын
That sounds like quite an interesting setup, how have you got it connected up?
@oscar.f.2 жыл бұрын
Cómo reseteo eso?
@ImpracticalMachinist2 жыл бұрын
To restore the factory settings go to P00.13 and select 10.
@oscar.f.2 жыл бұрын
@@ImpracticalMachinist muchas gracias!
@samtuladhar40092 жыл бұрын
Hello Sir, What is the value for P00.00 (Mains frequency) for my Spindle 1.5 kw, 220 v, 8 A, 400 Hz water Cooled spindle. I have same YL620 -A- 1.5kw , 220 v Vfd I am having tough time in setting Vfd. Sir, can you share your Vfd setting. Thank you
@ImpracticalMachinist2 жыл бұрын
P00.00 should be your mains input frequency. That will depend on where you are in the world, in the UK/Europe/Asia it would be 50hz. in the North/South America 60hz.
@samtuladhar40092 жыл бұрын
@@ImpracticalMachinist Thank you Sir
@ScruffR703 жыл бұрын
12:40 & 13:20 actually 10V - VI1 - GND are for the potentiometer (BTW it's an "i" for _input_ in VI1). A potentiometer would be connected across 10V - GND and the wiper pin would connect to VI1. However, I cannot find any useful documentation of the actual use of the AO (analog out - simulation output) nor of the electrical characteristics (i.e. max current) of the 13V pin. Also XVCC is somewhat obscure as it sources 15V but the docs call it "15V external input". The MO (triode output) is another obscure one I cannot find any useful documentation about.
@ImpracticalMachinist3 жыл бұрын
Quite right about the pot terminals, frustratingly I didn’t notice the mistake while I was putting the video together. This arrangement seems fairly common among vfd’s with this sort of layout, it’s the same on my HY vfd. I’d be really interested to see what the AO actually does too.
@jasonestes89542 жыл бұрын
The manual says, "Please lower the carrier frequency when there is a longer distance between the inverter and the motor..." I see no settings to adjust the carrier frequency, but the specs do say it is adjustable between 1kHz and 15kHz. Is there a setting for Carrier Frequency?
@ImpracticalMachinist2 жыл бұрын
It looks like the setting you want is P12.19 PWM frequency, by default it should be set to 8khz
@jasonestes89542 жыл бұрын
I see it now, thanks! I was searching for Carrier and could not find anything in the electronic version of the doc.
@manyhatershere17213 жыл бұрын
need to increase the volume... can't hear anything.
@ScruffR703 жыл бұрын
16:55 AFAICT these DIP switches are there to set the analog control voltage. 1100 would set it to 0-10V control while 0000 will set it to 0-5V control.
@ImpracticalMachinist3 жыл бұрын
That’s quite useful to know, the problem is that with the corrections and input you and others have made I’ll have to go and make a new video.
@arsyadtech2 жыл бұрын
Good job, like my vfd yl620a. Thanks for sharing
@musicstore1897 Жыл бұрын
Hello, thanx for the video. Do you know how to restart this vfd to factory reset?
@johannescordier79233 жыл бұрын
Hey nice vid , is it just me or is the volume a tad low ?
@tomrspears3 жыл бұрын
I have the same one and can't get it to go above 50 hz. I need 60hz. Any idea on which settings I need to change to get it to go to 60
@Xenomorphin13 жыл бұрын
Having issues with one of these - seems like my neutral is directly connected to my ground, which trips breakers. Do I have a lemon, or is this how it's supposed to be? Losing my mind looking all over the internet for anything of help. Even the seller doesn't know whether it's a fault or on purpose.
@ImpracticalMachinist3 жыл бұрын
Obviously that’s not supposed to happen, have you checked the continuity between the earth and neutral with a multimeter? It definitely sound like a short somewhere. Is this the case with nothing else wired? No motor, no switches, just the power feed to the unit.
@Xenomorphin13 жыл бұрын
@@ImpracticalMachinist there is a direct short between ground and neutral. Like on the screw terminal of the vfd itself. Yeah, I have set the multimeter to ohms and I'm getting 0.5 ohm on it.
@Xenomorphin13 жыл бұрын
@@ImpracticalMachinist i have a switch on the way, but it wasn't the problem - I have removed the vfd power cable and then the entire enclosure, with 2 power supplies and 4 nema23 steppers and drivers was working wonderfully. Tommorow I'll be testing on just straight plug to the socket, dont have a cable handy so I have to borrow one from the neighbors.
@ImpracticalMachinist3 жыл бұрын
@@Xenomorphin1 I'm having trouble visualising the setup. Are you saying that the VFD isn't wired straight through to a plug? If it's working outside the enclosure then there would seem to be the answer, you mention that you've got psu's and drivers, are you splitting the incoming AC between them with terminal blocks inside the enclosure?
@Xenomorphin13 жыл бұрын
@@ImpracticalMachinist it won't be working outside of the enclosure either. I'll update you after I test it.
@NatureAccents3 жыл бұрын
hello..can you update setting for 400hz?
@ImpracticalMachinist3 жыл бұрын
I’m sorry, I’m not quite sure which setting you mean?
@NatureAccents3 жыл бұрын
@@ImpracticalMachinist what I mean is the parameter setting for 400HZ 2.2KW 220V motor
@ImpracticalMachinist3 жыл бұрын
That’ll be according to whatever the specs are for your spindle. The spreadsheet is really just to provide a better, clearer translation of some of the programmable functions.
@NatureAccents3 жыл бұрын
@@ImpracticalMachinist how about 2nd video?
@ImpracticalMachinist3 жыл бұрын
When I get a free couple of days, I’m looking forward to getting it filmed.
@thetattooshow27513 жыл бұрын
i confirm at 16:45 its the RS485 communication
@shakilshaikh80473 жыл бұрын
Hello, Great explanation, any chance to get modbus working for this VFD? thanks in advance.
@ImpracticalMachinist3 жыл бұрын
Modbus isn't something that I've played with yet, I have looked into it briefly and I'd like to try it out but it'll have to wait until I've got hold of a spare vfd, which isnt likely to happen any time soon.
@andersmeiniche2746 Жыл бұрын
Thoes 2 screws in the buten is not Earth.
@JALLAZZA4 жыл бұрын
Hi There, will you please post the page you used for the settings? I have the same vfd but the documentation is terrible. Im really having a tough time with the settings. I figured out "P03.08 = min spindle frequency/Hz" & "P03.09 = max spindle frequency/Hz".
@ImpracticalMachinist4 жыл бұрын
If you have a look at the description you'll find the manuals and setup sheet that I showed, and also the one that i created (the third link) which is clearer and has the settings that I used for my setup, along with some notes explaining what settings do. Let me know how you get on, and if you have any more questions.
@JALLAZZA4 жыл бұрын
@@ImpracticalMachinist Thanks for the reply, I got her dialed in. 🤠
@JALLAZZA4 жыл бұрын
We got the exact same model.
@ImpracticalMachinist4 жыл бұрын
That’s great to hear!
@JALLAZZA4 жыл бұрын
@@ImpracticalMachinist If you want I can send you the entire list of settings that I have compiled. It should save you a ton of time. Im running the YL620-A with 220v 1.5kw watercooled motor. She runs very quiet and smooth too with these settings.
@rubenuribe57322 жыл бұрын
Gracias
@ImpracticalMachinist2 жыл бұрын
De nada
@yettimusafri44103 жыл бұрын
hi! thank you for the video it help so much! any I have a problem with the inverter I need your help. The spindle is suddenly stops running and the VFD shows Error 4. I already watch some tutorial and i set up again by doing factory reset. The error 4 disappeared but when i try to rotate the panel potentiometer the frequency shows 10Hz the spindle is not move, until i set 47 Hz the spindle is move. But the rotation is different, it is less noisy but i feel there is something wrong. Do you have any idea? thank you
@ImpracticalMachinist3 жыл бұрын
I suspect this will be your minimum torque settings. You’ll want to have a look at settings P00.09 and P00.10, which are the minimum frequency and voltage respectively. Have a look at the spreadsheet for the default values, and let me know how it goes. This might also be a problem with your potentiometer setting, you’ll need to set the minimum and maximum settings for the potentiometer to match the minimum and maximum output frequency.
@yettimusafri44103 жыл бұрын
@@ImpracticalMachinist I have try to setting P00.09= 0.2 Hz and P00.10= 1% but it didn't work
@yettimusafri44103 жыл бұрын
my vfd shows Er 4 again, what should I do? can you help me?
@ImpracticalMachinist3 жыл бұрын
Try setting p00.09 to 5 and p00.10 to 10.
@tidesrollin53433 жыл бұрын
Im having a terrible problem trying to commect this to UC300 by dream works . any Knowledge or do you know where I can look?
@ImpracticalMachinist3 жыл бұрын
Have you got a link to a manual? or some documentation?