Zehnder Comfoair 350 HRV Rough Installation

  Рет қаралды 25,862

Miphi Home

Miphi Home

Күн бұрын

Пікірлер: 16
@miphihome1851
@miphihome1851 8 жыл бұрын
As an FYI, when the Zehnder rep was here to commission the HRV, he noted how it was nice that we had this much separation between air intake and exhaust. We continue to be very happy with this system after being in the house for a month now.
@dreamhomes9050
@dreamhomes9050 2 жыл бұрын
what is the sound level when the system is running?
@raporbrt
@raporbrt 8 жыл бұрын
Hi, Could you tell me how did you calculate Volume for ventilation. Simple air volume calculation or did you take something else into consideration?
@Ningbovienne
@Ningbovienne 3 жыл бұрын
there is a software that i used : HB+ calculator burgerhout
@2awesome292
@2awesome292 9 жыл бұрын
Isn't the main intake/exhaust supposed to be on the same side of the house?
@miphihome1851
@miphihome1851 9 жыл бұрын
2Awesome I haven't heard of that. The building code is more concerned with separation of the exhaust from the intake/doors.
@2awesome292
@2awesome292 9 жыл бұрын
Miphi Home If the wind blows for example from the side of the house where the intake is, more air will move through the intake and positively pressurize the house. (and negatively when air blows into the air exhaust)
@miphihome1851
@miphihome1851 9 жыл бұрын
2Awesome That is a possibility, but in a different video I explained how we couldn't cut a 7" hole through our TJI and have the proper separation from the air exhaust, so the simplest was running it straight out the south end. But, it's not "required" to be on the same side.
@2awesome292
@2awesome292 9 жыл бұрын
Miphi Home im not sure on how far apart they should be, just that they should be on the same side of the house, i guess you would have to run it under the TJI joists which would be kinda be an eyesore. One of those energy standards gives you points for having the hrv/erv closer to a walls, maybe that's how they recommend it idk. Just found it, 6+' separation between intake/exhaust and at least 4+" off the ground for exhaust and 18+" off ground for intake
@brandonphelps8074
@brandonphelps8074 4 жыл бұрын
How do you like this unit now that you have been in the house for 4 years? Very expensive system when compared to a Broan HRV install. I got a quote for $11k for materials only for a 3200 sq ft house
Passive House - Fresh Air System Install & Costs (Zehnder)
34:49
Matt Risinger
Рет қаралды 355 М.
ERV/HRV vs Dehum - What’s the difference?
14:38
Matt Risinger
Рет қаралды 237 М.
Try Not To Laugh 😅 the Best of BoxtoxTv 👌
00:18
boxtoxtv
Рет қаралды 7 МЛН
Human vs Jet Engine
00:19
MrBeast
Рет қаралды 195 МЛН
Construction Maison Ossature Bois - Gaines VMC double flux Zehnder
21:16
Zehnder ComfoAir Q350 montavimas ir paleidimas
5:51
Mindaugas Malinauskas
Рет қаралды 22 М.
Installation of the Zehnder ComfoAir Q600 recuperator
1:29
Polski Instalator
Рет қаралды 28 М.
"Mechanical & Ventilation Rough" Build Show Build: Boston Ep. 13
1:11:47
How to Install Zehnder Comfosystems Part 1 - HRV
14:16
Zehnder America
Рет қаралды 96 М.
Fresh air: A quality ERV that most can afford?
14:27
Matt Risinger
Рет қаралды 130 М.
Installation VMC double flux Zehnder ComfoAirQ 450 dans le calvados
11:35
Quentin Delescluse
Рет қаралды 3,4 М.
Try Not To Laugh 😅 the Best of BoxtoxTv 👌
00:18
boxtoxtv
Рет қаралды 7 МЛН