ZQWC लोको में क्यों लगाया जाता है | QWC Relay का काम क्या है | Shunting Contactor का काम क्या है |

  Рет қаралды 23,098

Railway Talks

Railway Talks

Күн бұрын

#ZQWC_IN_LOCOMOTIVE
#ZQWC
#QWC
#SHUMTING_CONTACTOR
#RAILWAY_TALKS
#LOCOMOTIVE
ZQWC लोको में क्यों लगाया जाता है | QWC Relay का काम क्या है | Shunting Contactor का काम क्या है |
locomotive ZQWC SWITCH in hindi,
ZQWC SWITCH explain in हिंदी,

Пікірлер: 69
@ganapatimajhi3556
@ganapatimajhi3556 7 ай бұрын
Very good information sir
@sachinkumarsingh9506
@sachinkumarsingh9506 6 ай бұрын
Bahut achha
@raghupatrunirajasekhar7202
@raghupatrunirajasekhar7202 11 ай бұрын
Very excellent
@BaluSubbuBalasubramanya
@BaluSubbuBalasubramanya 8 ай бұрын
Superb sir
@Railway1998
@Railway1998 Жыл бұрын
Excellent
@abdulsamad1530
@abdulsamad1530 3 ай бұрын
Thankyou sir
@prashnnavardhanparashar1788
@prashnnavardhanparashar1788 3 ай бұрын
Thanks 🙏
@ravimeenadhanota502
@ravimeenadhanota502 Жыл бұрын
NICE SIR
@jaiparkashbarak7281
@jaiparkashbarak7281 Жыл бұрын
महत्वपूर्ण जानकारी देने के लिए धन्यवाद साहब
@ramanandmahto7053
@ramanandmahto7053 Жыл бұрын
Good video for running loco staff
@muthyamthirupathi9165
@muthyamthirupathi9165 2 жыл бұрын
Acha samaj gaya tq
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Welcome
@santoshmuduli688
@santoshmuduli688 3 жыл бұрын
ACCORDING TO RDSO... Relay QWC (Weight Transfer Compensation Relay):- Relay QWC is provided to reduce tractive effort at the time of starting by attaching resistance in parallel to the field coil to traction motor to avoid wheel slipping. On closing the switch ZQWC-1/ZQWC-2, relay QWC will energise between ‘0’ to ‘1’ notch and it will remain energized up to 15 notch. On pressing ZQWC-1 relay QWC gets energized, shunting contactors S-3,S-5 and S-6 get closed and shunting resistances RS-3,m RS-5 and RS-6 get attached in parallel to the field coil of TMS-3,5,6 to reduce tractive effort and thus to arrest wheel; slipping. On pressing ZQWC-2 - relay QWC energises and shunting contactors S-1, S-2 and S-4 get closed and shunting resistances RS1, RS2 and RS4 get attached in parallel to the field coil of TMs 1,2,4 to reduce tractive effort and thus to arrest wheel slipping.
@brajeshverma2024
@brajeshverma2024 Жыл бұрын
बिल्कुल सही जानकारी है।
@adijenne1001
@adijenne1001 6 ай бұрын
Tq brother
@user-fq5vr7bm5d
@user-fq5vr7bm5d 2 жыл бұрын
Excellent vdo
@NPSG0BACK
@NPSG0BACK 3 жыл бұрын
Lovely voice and style 🥇🥇♥️♥️
@RailwayTalks
@RailwayTalks 3 жыл бұрын
Thank you
@msanuragllb
@msanuragllb Жыл бұрын
Well explained
@indrajitmondal5104
@indrajitmondal5104 3 жыл бұрын
Khub sundor hoe6e
@RailwayTalks
@RailwayTalks 3 жыл бұрын
Thank you 🙏🙏🙏
@nagnathjanrao7375
@nagnathjanrao7375 2 жыл бұрын
सर बहुत अच्छा समझाया
@ChandanKumar-nc1nm
@ChandanKumar-nc1nm 4 ай бұрын
Baki information useful hai Bas ek mistake hai Cab 1 se tm 3,5,6 Aur cab 2 se 4, 2,1 Thank you ❤
@ABHISHEKKUMAR-ru5mp
@ABHISHEKKUMAR-ru5mp 2 жыл бұрын
Nice information sir jee
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Thank you
@thetruth9945
@thetruth9945 10 ай бұрын
Very good explanation 🎉
@SantoshKumar-lj5fi
@SantoshKumar-lj5fi 3 жыл бұрын
Very very nice sir 🙏
@RailwayTalks
@RailwayTalks 3 жыл бұрын
Thank you
@veerkarsh6581
@veerkarsh6581 2 жыл бұрын
Thank u SIR bhot ACHHE SE samajh me aaya
@mahendrakumarmeena8492
@mahendrakumarmeena8492 4 ай бұрын
ZQWC Used when loco started in up gradient section.if u used in level section its cause notch regression
@HarishKumar-bx8qq
@HarishKumar-bx8qq 2 жыл бұрын
Sir I understand so very clear
@SunilKumar-vd3zt
@SunilKumar-vd3zt 2 жыл бұрын
thANKS SIR
@user-fq5vr7bm5d
@user-fq5vr7bm5d 2 жыл бұрын
Sir please or bhi vdo banaye, apka vdo bht achha h
@ajaykumargupta8733
@ajaykumargupta8733 2 жыл бұрын
Bahut achcha sir
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Thank you
@amitavabiswas6613
@amitavabiswas6613 2 жыл бұрын
By adding shunting contactors parallel of the field, flux of field is weakened subsequently torque is reduced as torque is product of flux and armature current. In WAG5 loco axle no. 1,2 and 4 is off loaded statically and dynamically due to its bogie structure. To compensate imbalance weight transfer is done electrically by QWC by adding shunt field at parallel of field.
@manishkumar-sm7lp
@manishkumar-sm7lp 2 жыл бұрын
Siir g bahut accha padhaya apne
@chetanupadhyay6455
@chetanupadhyay6455 2 жыл бұрын
Very nice bhai 👍👍
@gauravjha2412
@gauravjha2412 2 жыл бұрын
I really like sir thank u
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Welcome
@mdezazulhaque6435
@mdezazulhaque6435 2 жыл бұрын
Good explain
@podilapuvenkataramana4292
@podilapuvenkataramana4292 3 жыл бұрын
Nice sir
@RailwayTalks
@RailwayTalks 3 жыл бұрын
Thank you
@RAUSHANKUMAR-ki1ec
@RAUSHANKUMAR-ki1ec Жыл бұрын
Super sir🙏🙏🙏
@imtiazsiddiqui8333
@imtiazsiddiqui8333 2 жыл бұрын
thanks sir
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Welcome
@vipulgupta6957
@vipulgupta6957 Жыл бұрын
Sir conventional loco lagatar kitna current de sakte h
@santoshmuduli688
@santoshmuduli688 3 жыл бұрын
Sir harmonic filter ka uper ek vdo banayiye..
@samarpal6211
@samarpal6211 Жыл бұрын
Wap4 loco me zqwc prass krne pr kon kon se shunting contactet close hote h.
@bhabanishankarpusti8905
@bhabanishankarpusti8905 2 жыл бұрын
When loco moves toward cab1, on pressing zqwc shunting resistance added to field of TM-3,5,6. Not with 1,2,4
@shaibalranjanbarik9876
@shaibalranjanbarik9876 2 жыл бұрын
Make a video on WAP4 under truck.as totally different
@dharmveershastri818
@dharmveershastri818 2 жыл бұрын
Thanks sir, your explanatn excellent excellent excellent.please continue...
@shaibalranjanbarik9876
@shaibalranjanbarik9876 2 жыл бұрын
Super, sir BPQD ka video pls
@arunjana1952
@arunjana1952 2 жыл бұрын
battery ka man bathiya
@neerajmishra9412
@neerajmishra9412 2 жыл бұрын
Best explain.. thanks sir🙏
@KIRANKUMAR-zp2bf
@KIRANKUMAR-zp2bf 2 жыл бұрын
Thank you Sir. It's easy to understand
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Welcome
@uttam1214
@uttam1214 2 жыл бұрын
Bpqd 10 noch Tak kam krega. na ki Zqwc
@shshankkumar444
@shshankkumar444 2 жыл бұрын
Galat bata rha hai
@seshagiripopuri5059
@seshagiripopuri5059 2 жыл бұрын
0 to up to 10th notch continuous press hold on ZQWC swtch kam karth?
@rajat_mondal
@rajat_mondal 2 жыл бұрын
টেস্টিং এর সময় এটা LT mode -এ দেখা যায়?
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Hmm low tension test er smy ZQWC ka operate kora dakte hoy 3rd group shunting contactors gulo close ho66e kina
@gayatridash6034
@gayatridash6034 2 жыл бұрын
Sir shunting contactor closes after taking 10 notch. It is true or false.
@brajeshverma2024
@brajeshverma2024 Жыл бұрын
बिल्कुल गलत तरीके से समझा रहे है। सही जानकारी देने का प्रयास कीजिए
@SubhashChandra-pw9ib
@SubhashChandra-pw9ib 8 ай бұрын
*ulta bta rhe hai*
@sureshmeghwaldttc7242
@sureshmeghwaldttc7242 2 жыл бұрын
सर जी इसको एक बार सर्किट से समझा देना धन्यवाद सर जी
@RailwayTalks
@RailwayTalks 2 жыл бұрын
Ok
@sureshmeghwaldttc7242
@sureshmeghwaldttc7242 2 жыл бұрын
धन्यवाद सर जी
@JahangirAlam-rp5ek
@JahangirAlam-rp5ek 6 ай бұрын
Very nice sir
Safety of GR ( Tap Changer)#indianrailways #locomotive
11:27
Knowledge Gain
Рет қаралды 6 М.
Bend The Impossible Bar Win $1,000
00:57
Stokes Twins
Рет қаралды 44 МЛН
小丑和白天使的比试。#天使 #小丑 #超人不会飞
00:51
超人不会飞
Рет қаралды 39 МЛН
WILL IT BURST?
00:31
Natan por Aí
Рет қаралды 44 МЛН
PILOT LAMP
21:06
LOCO GYAN
Рет қаралды 73 М.
precautions after wedging relays. why take precaution
12:36
knowledge upto date
Рет қаралды 34 М.
Trouble shooting.Total loss off tractive effort. LSGR not extiguishes.
8:46
knowledge upto date
Рет қаралды 26 М.
FUSE Concept in Conv. Elec Loco #locomotive#railway
10:14
Knowledge Gain
Рет қаралды 7 М.
Bend The Impossible Bar Win $1,000
00:57
Stokes Twins
Рет қаралды 44 МЛН