No video

Zurn Wilkins Automatic Control Valves - How it Works

  Рет қаралды 106,927

Zurn Water, LLC

Zurn Water, LLC

Күн бұрын

This animation shows the internal adjustments made by the Zurn Wilkins ZW209 Automatic Control Valve during normal operation, allowing the valve to hold constant outlet pressure regardless of changing flow rates and inlet pressure. Click here to see more information about the ZW209: www.zurn.com/Pa...

Пікірлер: 12
@WyrmholeWarrior
@WyrmholeWarrior Жыл бұрын
Easy to understand! Thanks!
@mirandagroboske548
@mirandagroboske548 9 жыл бұрын
Excellent video! Thank you for sharing!
@paulfox521
@paulfox521 4 жыл бұрын
That was awesome video
@dannychristianto7691
@dannychristianto7691 7 жыл бұрын
hi.. What would happen if the pressure upsteam the control valve drops below the set point (55 psig)? will it fully open or close? really appriciate your answer... thx
@ZurnIndustries
@ZurnIndustries 7 жыл бұрын
Hi, Danny. Should the inlet pressure drop below the set point, the valve will be in an open condition, and out of control. The valve requires a minimum of a 10 psi differential across the valve to remain in control. If you have any more questions, feel free to contact the Zurn Wilkins Customer Care department at 1-855-ONE-ZURN (1-855-663-9876).
@welltime4645
@welltime4645 4 күн бұрын
There no crd what happened?
@kremesti
@kremesti Жыл бұрын
Are the gauges important for commissioning?
@smsom1591984
@smsom1591984 6 жыл бұрын
Hi , what is the difference between this type and the type with Low-flow Bypass ? Thanks
@ZurnIndustries
@ZurnIndustries 6 жыл бұрын
All ACVs of the Pressure Reducing variety have minimum continuous flow requirements. As long as the minimum continuous flow rate is above the minimum flow rate of the ACV, no low-flow by-pass is needed. In the event the flow rate drops below the minimum continuous flow rate of the ACV, a low-flow by-pass is called for. In the case of the ZW209BP, we add a small direct acting Pressure Reducing Valve to the backside of the ACV. The small PRV will handle all low-flows through 10 GPM. This is the main difference between the ZW209 and the ZW209BP.
@smsom1591984
@smsom1591984 6 жыл бұрын
thank you for reply . one more thing , in case of no flow , will downstream pressure stay at set pressure by using the ZW209 or need to add Bypassin this case ?
@TanweerAhmed
@TanweerAhmed 5 жыл бұрын
Good explained about PRV #tanweerahmed
@fmepengineering3435
@fmepengineering3435 Жыл бұрын
Quotation team india
Zurn Wilkins Automatic Control Valves ZW209BP - How to Commission
8:54
Cla-Val CRD Pressure Reducing Pilot Set-Up Instructions
17:40
Cla-Val Headquarters
Рет қаралды 78 М.
Они так быстро убрались!
01:00
Аришнев
Рет қаралды 3,1 МЛН
Doing This Instead Of Studying.. 😳
00:12
Jojo Sim
Рет қаралды 35 МЛН
Lehanga 🤣 #comedy #funny
00:31
Micky Makeover
Рет қаралды 29 МЛН
Installing a Zurn Wilkins ZW209 Automatic Control Valves
7:28
Zurn Water, LLC
Рет қаралды 17 М.
Understand All about Balancing valve Part 01
8:17
HVAC-R -BE PROFESSIONAL
Рет қаралды 5 М.
Watts - Socla ACV's
7:52
Marc Desfontaines
Рет қаралды 26 М.
Fire Suppressions Systems Training Part 3: Pressure Reducing Valves
8:48
MiamiDadeFireRescue
Рет қаралды 13 М.
Cla Val 90 01 PRV Live Demo of Operation
10:20
Cla-Val Headquarters
Рет қаралды 41 М.
TYCO. PRV-1 Pressure Regulating Valve
2:32
videoproektant
Рет қаралды 645 М.
720 ES Pressure Reducing Valve - Operation
3:45
Bermad Water Technologies
Рет қаралды 426 М.
How pressure reducing valve works, PRV working principle (PRV Operation)
3:49
MEP Engineering Tutorials
Рет қаралды 67 М.
Campbell-Sevey - How a Pilot Operated Regulating Valve Works
1:51
Campbell Sevey
Рет қаралды 104 М.
Они так быстро убрались!
01:00
Аришнев
Рет қаралды 3,1 МЛН