@andrewalderson1
@andrewalderson1 22 сағат бұрын
Hi Richard. I fitted one of these with a vaillant heat pump recently and I piped it up A to rads and B to cylinder, I wired it the opposite way around to what you suggested. It seems to work fine but is there any downside to doing one way or the other?
@nonny3021
@nonny3021 Күн бұрын
Thank you for making it so easy!
@iannaification
@iannaification Күн бұрын
Hi (again), we have a single dying CM927 thermostat paired to a BDR91 receiver for a gas boiler. Is it possible to simply replace with DT4R as shown here?
@deanchapple1
@deanchapple1 Күн бұрын
Great video Rich, bout time someone did an in-depth no nonsense video on ESBE! Thank you.
@iannaification
@iannaification 2 күн бұрын
Hi, we have a dying CM927 (up button for temperature no longer works) and it is paired to a BDR91 receiver. (Gas boiler). Can we just buy a wireless thermostat - either Pro or T3R wireless and pair it to the existing receiver? Thanks
@MWPHS
@MWPHS Күн бұрын
T3R won’t work, but if you buy this one we include instructions how to pair it to your existing BDR91 - theintergasshop.co.uk/home/99-cms927-7-day-wireless-programmable-room-thermostat-cms927b1049.html
@subscribe4003
@subscribe4003 4 күн бұрын
Would you be able help please. How do you connect the thermostat to the programmer if you don’t have a relay box fitted, mine was fitted without one had been ok, now have a flashing signal but won’t connect
@stedoesstuff
@stedoesstuff 4 күн бұрын
Thank you so much for this!
@MWPHS
@MWPHS Күн бұрын
No problem! 👍🏻
@stud81
@stud81 7 күн бұрын
Will this room thermostat be good to replace my dirty old potterton prt100 thermostat? I have red, black, yellow and earth into my old thermostat. Thanks
@MWPHS
@MWPHS Күн бұрын
Yes it will
@stud81
@stud81 Күн бұрын
​@@MWPHSwith my old stat being wired with old wires I have red live in terminal 1 yellow in 2 will this be my switch wire? Thanks
@MWPHS
@MWPHS Күн бұрын
@@stud81 normally red and yellow will be live and switched live.
@mozhgannaderi2353
@mozhgannaderi2353 9 күн бұрын
Thanks for your help😊
@MWPHS
@MWPHS 8 күн бұрын
Most welcome 😊
@AparnaAmbre
@AparnaAmbre 9 күн бұрын
What to do when your thermostat shows an error - SYNC? The green light on the heating side is not working. I tried everything to turn it on but it doesn't help. How can I start the heating?
@MWPHS
@MWPHS 8 күн бұрын
Sounds like you might have a faulty BDR91 relay box? The thermostat is trying to look for it if it’s saying ‘SYNC’.
@AparnaAmbre
@AparnaAmbre 3 күн бұрын
I don’t think it’s faulty bcz earlier heating was working. Anyway, do you provide any home visit service to sort out our heating system from Honeywell? We are from London. How can I reach Honeywell customer service in London?
@MWPHS
@MWPHS 2 күн бұрын
@@AparnaAmbre I'm just an ex-heating installer on KZbin creating these videos. Best thing to do is contact Resideo (Honeywell Home) and see if they have a trained installer in your area - 0300 130 1299.
@onedartmart7707
@onedartmart7707 16 күн бұрын
Very helpful and well explained. Im fitting mine tomorrow now I’ve seen this video. Thank you.
@onedartmart7707
@onedartmart7707 15 күн бұрын
Brilliant. Thank you, all went exactly as you described. 10/10
@MWPHS
@MWPHS 8 күн бұрын
No problem… Thanks for commenting! 👍🏻
@pawelborecki844
@pawelborecki844 18 күн бұрын
Thanks. Helpful video.
@MWPHS
@MWPHS 8 күн бұрын
You're welcome!
@UrbanPlumbers
@UrbanPlumbers Ай бұрын
yes - balls being detached from the body is getting pretty common. If only most manus weren't suppling spring return valves with their kits.
@evasco1979
@evasco1979 Ай бұрын
Thanks, this helped immensely!
@MWPHS
@MWPHS Ай бұрын
You're welcome!
@TherealWottie
@TherealWottie Ай бұрын
My hot water in one part of the house is sat at 24 degrees but fine in the other part of the house? Any ideas?
@MWPHS
@MWPHS Ай бұрын
Solar gain and low heat loss at this time of year?
@jjohnson-stoker
@jjohnson-stoker Ай бұрын
Very helpful video. Just what I needed to know.👍
@MWPHS
@MWPHS Ай бұрын
Glad it was helpful!
@roberts6583
@roberts6583 Ай бұрын
Hi, do I need to use the relay? I have a building with 8 rooms and each room has 2/3 zones and I’d like each room to be able to set their own temperatures, as the TRVs currently installed are inaccessible behind rad covers. So ideally each room would have a controller, sensor in each room and HR92s on each rad.. Do I need the relay for this, I’m not sure the WiFi would reach the boiler room. Hope this makes sense.
@MWPHS
@MWPHS Ай бұрын
Normally you would use the relay to control the heat source, otherwise the heat source would have to run 24/7 ready for when there was a demand.
@tomplumb7754
@tomplumb7754 Ай бұрын
😂
@ESBEGroup
@ESBEGroup 2 ай бұрын
Congrats from Sweden and ESBE to all the winners of the Treasure hunt competition!
@andrewriley4204
@andrewriley4204 2 ай бұрын
Ooo Cor-blimey ! 😯 😀 😃
@YagiChanDan
@YagiChanDan 2 ай бұрын
It will be an honour to set sail with Discount Captain Jack Sparrow and the other landlubbers. 😆
@beexpressplumbing
@beexpressplumbing 2 ай бұрын
Whoop whoop whoop :-)
@PaolaM-p4t
@PaolaM-p4t 2 ай бұрын
Should the green light on the relay box be always on ?
@MWPHS
@MWPHS Ай бұрын
No, only when there is a demand from the thermostat.
@AndyGait
@AndyGait 2 ай бұрын
Thank you very much. Just what I needed. Noticed the flashing lights on the receiver, but couldn't find the instruction manual anywhere. Did the job in no time. Thanks again.
@MWPHS
@MWPHS Ай бұрын
You're welcome!
@jeremylam9804
@jeremylam9804 2 ай бұрын
Hi there, I hope you can help me. My DT4 is blinking with error code “F 22”. I can’t find anything on the web about it. Do you know what it means? Cheers
@MWPHS
@MWPHS Ай бұрын
I don't, but Resideo technical support is on 0300 130 1299.
@eointyrrell
@eointyrrell 2 ай бұрын
EXACTLY what I was looking for. Thanks
@MWPHS
@MWPHS Ай бұрын
No problem!
@moonshine3333
@moonshine3333 2 ай бұрын
Hi, I do hope that you can help. I have just watched how to remove a Honeywell clicky thermostat and the video was 100% accurate. It shows/I have red, yellow and blue wires powering it . The rest of the house setup is exactly as you show … I have the Honeywell timer for hot water/heating. Can I fit the thermostat you suggest and is so what are the wiring positions? Thanks in advance.
@MWPHS
@MWPHS 2 ай бұрын
The DT4 can replace any existing non-programmable thermostat. Unfortunately, I can only comment about the thermostat we used in the video (which is also the equivalent to a Honeywell T6360 clicky stat). The wires that are in wiring terminals 1 & 3 on the existing thermostat, are the live and switched live wires. You use these wire (and these wires only) in the DT4 switching terminals, the rest of the wires are made safe as I've shown. If you need any technical support with the DT4 product, please contact Resideo on 0300 130 1299. Thanks for watching the video.
@moonshine3333
@moonshine3333 2 ай бұрын
@@MWPHS I REALLY do appreciate you taking the time to answer. Thank you👍
@moonshine3333
@moonshine3333 2 ай бұрын
So clear, thank you very much.
@MWPHS
@MWPHS 2 ай бұрын
You're very welcome!
@brittonsjewellers9613
@brittonsjewellers9613 2 ай бұрын
If my cm927 is not working correctly and I replace with another cm927 controller Will the replacement pair without disconnecting the original controller
@MWPHS
@MWPHS 2 ай бұрын
It will but make sure you remove the batteries of of the old CM927 so it doesn't interfere with the new thermostat.
@johnc4323
@johnc4323 3 ай бұрын
Any disadvantage of using the mixing esbe valve over the diverter type so long as the correct head is used as a doverter?
@MWPHS
@MWPHS 3 ай бұрын
No disadvantage as long as there is an understanding that the shoe is in the correct position when the actuator is fitted.
@fape91
@fape91 3 ай бұрын
Hi, I like your videos. Do you have another one with water tank and hot water Y plan, using evotouch and radiator valves for temperature sensors?
@MWPHS
@MWPHS 3 ай бұрын
I am planning a full revamp of all our evohome videos shortly. Full guides for everything evohome start to finish. Watch this space. 👍🏻
@chrisbw591
@chrisbw591 3 ай бұрын
I’m glad you backed yourself up with not 100% on the voltage pen but a multimeter isn’t a HSE GS38 approved tester to confirm the electricity is dead - should be using a 2 pole voltage indicator or test lamp and a known source such as a proving unit
@MWPHS
@MWPHS 3 ай бұрын
Thanks for your input. I'll be honest, I knew this but I'm dyslexic and mixed up the wording on the video. I'll make sure on the next video I use the correct terminology.
@fanofmussic
@fanofmussic 3 ай бұрын
Not working for me. Same old thermostat (THR830T), same wiring, connecting Live to A and Live out (load) to B but nothing is happening. Not sure if it matters that I have a zone valve on the system, not sure if wiring is different in that case, but I have a programming unit similar like in this video, it is on continuous on but no luck 😢
@MWPHS
@MWPHS 3 ай бұрын
Unfortunately you have multiple fail points in a heating system, so its best to call a heating installer to come and look at the system for you.
@fanofmussic
@fanofmussic 3 ай бұрын
​@@MWPHS I made it work, but it is weird. On the old thermometer, on your video on number 2 you have blue neutral wire and I have blue and black together on 2, and the new one is working ONLY when those two (blue and black) have contact... So I connected them and isolated them with tape and it's working. No idea why...
@DragonXDrei
@DragonXDrei 3 ай бұрын
Shouldn't that be a 13A fuse? I want to get underfloor electric heating and thought 13A is what I should be using.
@MWPHS
@MWPHS 3 ай бұрын
The DT4 thermostat is only capable of a maximum switching current of 3 amp resistive. Please don't use 13 amp fuses with these thermostats.
@DragonXDrei
@DragonXDrei 3 ай бұрын
@@MWPHS In short, I inherited electric underfloor heating, but no idea if it is working. The old one is a honeywell t6360 and I would like to replace it but no idea with what and what fuse to use on it.
@kimclewlow6054
@kimclewlow6054 3 ай бұрын
Please could you post a video of how to use and what setting your boiler should be on as I can't seem to get ours to work. Thank you
@MWPHS
@MWPHS 3 ай бұрын
A full video knowledge centre is about to be created on our channel. Please keep subscribing to our channel to be notified when new videos are released about the products we sell.
@RichardBrown-oi5jz
@RichardBrown-oi5jz 3 ай бұрын
My son has just moved into rented house and it has this Honeywell thermostat,the he gets hot water but no heating even tho the thermostat display clicks and shows the heat symbol as if it has come on ,i have searched the house and cant find the relay box you speak of in this video. Is the relay box a must for this thermostat to work ? Soryy if this is a stupid question but i know nothing of how these things work 😊
@MWPHS
@MWPHS 3 ай бұрын
The thermostat in this video is wireless, but the one your son has is probably a DT90E. This might help ( support.resideo.com/s/article/Where-can-I-find-the-user-guide-for-the-DT90E-thermostat?language=en_US ).
@menacemenupat9667
@menacemenupat9667 3 ай бұрын
Does the T6r work with that receiver doyou know please?
@MWPHS
@MWPHS 3 ай бұрын
No, T6 is a Ramses 3 protocol thermostat so only works with the R6H receiver ( www.resideo.com/gb/en/products/comfort/thermostats/thermostat-accessories/r6h911rf4018-2-channel-wireless-receiver-box-r6h911rf4018/ ).
@menacemenupat9667
@menacemenupat9667 3 ай бұрын
@@MWPHS thank you. I'll be sure to get the complete package to replace the T3r. Thanks for replying 🙂
@povilaszukauskas5535
@povilaszukauskas5535 4 ай бұрын
Super thank you ❤
@MWPHS
@MWPHS 4 ай бұрын
You are so welcome!
@simonjohnson6751
@simonjohnson6751 4 ай бұрын
Thanks for this. Have now re set and all ok.
@MWPHS
@MWPHS 4 ай бұрын
Glad it helped
@karenwalker3089
@karenwalker3089 4 ай бұрын
Thank you. Your video took me step by step to confidently reinstate the heating.
@MWPHS
@MWPHS 4 ай бұрын
Glad to hear this Karen! :)
@patrykpiwonski3990
@patrykpiwonski3990 4 ай бұрын
I’ve done all steps one by one which is fine but at the end on the relay box and light didn’t on. Do you know why or what’s the problem with it ? Thank you for help
@MWPHS
@MWPHS 4 ай бұрын
Sometimes, you have to turn the thermostat all the way down and then all the way back up again. Also make sure the thermostat is set higher than the room temperature. If you need support, call 0300 130 1299.
@Suepalmer42
@Suepalmer42 4 ай бұрын
Please can you make a short video showing lay person how to operate the thermostat once it is installed. Eg. What are set temp adjust buttons for / what is eco mode in reality etc ? Plus/ Minus / Flame etc are clear but what about all the other functions? Thank you 🤔😊
@MWPHS
@MWPHS 4 ай бұрын
I'll see what I can do! :)
@alexojus
@alexojus 4 ай бұрын
That's a BDR91 thermostat! Not like the one that your sister company MWPHS sent me!! Now, after sending it back, you refused to refund me claiming it was damaged!! My engineer only tried to connect to the Honeywell thermostats and didn't install it on the wall! Even Honeywell didn't recognise the model of the receiver you sent me when we called them to try to fix the issue. The worst is that I'm sure Waseem believed his own lies!! Your company shouldn't be ashamed!!
@MWPHS
@MWPHS 4 ай бұрын
The BDR91 is manufactured in many different shapes under many different product codes, so they won't always look like the one in this video. Essentially they all do have the same PCB, so do work exactly the same as in this video. If you have a look at the video we did 9 months ago (kzbin.info/www/bejne/ql6pmYKtfLxqhdksi=xBGuYJCwbxrz4bQO), both the BDR91 and the DT2 wireless relay box (which is essentially a BDR91 with a different plastic fascia) are fully compatible with all Ramses 2 Honeywell thermostats. The DT2 wireless relay box supplied on MWPHS (mwphs.co.uk/product/wireless-relay-box-bdr91-replacement-replaces-all-pre-2021-honeywell-bdr91/) is fully compatible with all Ramses 2 thermostats? What was the problem you had maybe I can look into this for you? Thanks, Richard.
@alexojus
@alexojus 4 ай бұрын
@@MWPHS Hi Richard, sorry if I can't call, but as mentioned to Waseem, I can only send emails when I'm at work. I ordered two BDR91, one from Amazon and one from you. Both are to connect with a DT4 thermostat. The one I bought from Amazon connected straight away to my DT4, the one I ordered from you didn't connect. We didn't install it, no screws, nothing. We did nothing to that receiver apart from trying to connect to the thermostat. I didn't check the receiver when I received it but I only noticed that it was in a bubble wrap rather than in its box like the one I received from Amazon. Waseem said that the box had been destroyed in transit... It's only when my engineer came to install everything that he noticed the difference between the two receivers. You claim that they are the same, they are not or yours is faulty...Waseem or your company keep saying you sent the right receiver but you didn't and that the receiver was damaged or in used condition. If it was damaged, ( I saw the pictures and unless, you look for it, you wouldn't noticed), it wasn't by us! I paid for a delivery postage, a return postage and a receiver that it's either the wrong one or is not working and you're refusing for a refund. As I said, next time, I'll go to Amazon, much easier and they don't blame the customer for things they haven't done.
@MWPHS
@MWPHS 4 ай бұрын
@@alexojus I had replied to you before realising you had left our business two 1 star reviews on Google and a negative Trustpilot review? I have physically seen the wireless relay box you returned with my own eyes and I don’t think I have seen many items returned to us in such poor condition? It is completely unsaleable. It is now not about the money, it’s about the fact we are being call liars and scammers when we have refused to refund an item that has been returned in unsaleable condition. We are not Amazon, we are a small family owned heating supplier who has been running for 10 years. Some of our items are bought direct from the manufacturer as an OEM replacement. All the wireless relay boxes we supply are checked/picked to order by our warehouseman (who is called Nick, been with us 7 years and religiously checks all items before dispatch) and they are packed in electrostatic packaging to protect them from physical and electromagnetic damage. This is not bubble wrap. If you want the detail on the bags we use they are here ( www.kitepackaging.co.uk/scp/bags-for-electronics/open-top-antistatic-bag/ ). When I get into work tomorrow I will get the DT4R I use for my KZbin videos and test the wireless relay box you have sent back for operation, however the reason you have given for return was that it wasn’t a BDR91. So is the reason for return that the item is faulty? If that is the case that wasn’t clear from the returns paperwork or discussion I had with Waseem?
@umedgalchabekov2451
@umedgalchabekov2451 4 ай бұрын
How to unlock it?
@MWPHS
@MWPHS 4 ай бұрын
This might help (kzbin.info/www/bejne/a2LLfpKMjseafqs), otherwise contact support on 0300 130 1299.
@umedgalchabekov2451
@umedgalchabekov2451 4 ай бұрын
@@MWPHS it’s really helped me thank you so much
@Norby35
@Norby35 4 ай бұрын
I have two wired DT4s one floor of the house and one wired on another. I would like to change this one to a wireless so I can site it more efficiently. Is this possible or will the system get confused? Thanks for any advice
@MWPHS
@MWPHS 4 ай бұрын
You can, but bear in mind the DT4 is only a 2 wired connection so you would have to have this appropriately wired to accomplish this.
@Uz4air
@Uz4air 4 ай бұрын
I have a cm707 how do i connect my cm707 honeywell on my system s15 boiler.
@MWPHS
@MWPHS 4 ай бұрын
CM707 is a wired thermostat. Contact Resideo for support on 0330 130 1299.
@Uz4air
@Uz4air 4 ай бұрын
@@MWPHS so can i connect it then
@MWPHS
@MWPHS 4 ай бұрын
@@Uz4air if you don't know how to do this, contact an installer and they will do it for you.
@EtienneL-it2gp
@EtienneL-it2gp 4 ай бұрын
Nice video ! Do you know if the Evohome and HM80 can control the main mixing valve of my installation (not only for a zone) ?
@MWPHS
@MWPHS 4 ай бұрын
Hi, evohome and a HM80 (if you can find one) controls mixing at zone level only.
@EtienneL-it2gp
@EtienneL-it2gp 4 ай бұрын
@@MWPHS Ok. That means it is impossible to configure the Evohome to control the 3 way mixing valve depending on the whole house demand ?
@MWPHS
@MWPHS 4 ай бұрын
@@EtienneL-it2gp why would you have a mixing valve controlling the whole house? A mixed circuit is usually part of more than one zone where the temperature to the one circuit is higher than the second circuit (1x radiator circuit and 1x UFH for example).
@EtienneL-it2gp
@EtienneL-it2gp 4 ай бұрын
@@MWPHS The main 3-way valve makes it possible to precisely adjust the water temperature of the whole circuit according to the needs of the radiators. My installation was designed like this.
@MWPHS
@MWPHS 4 ай бұрын
@@EtienneL-it2gp ok, well evohome is not designed to work like this unfortunately.
@townman3794
@townman3794 4 ай бұрын
Very clear video. Would the DT4R be a good replacement for the Sunvic TLX 2259. In particular would the backplate of the 2259 accomodate the DT4R without needing to drill new holes etc? I have a conventional boiler (Gloworm)? Many thanks.
@MWPHS
@MWPHS 4 ай бұрын
Hi, looking at the Sunvic TLX 2259 the shape looks like it fits a standard UK backplate, so should have similar fixing holes to the DT4. Please note that the DT4R is the wireless version, the product in the video is a DT4 (mwphs.co.uk/product/honeywell-home-dt4-white-wired-tpi-thermostat-dt40wt20/).
@townman3794
@townman3794 4 ай бұрын
@@MWPHS That's great, thank-you.
@DavinderSingh-xs5uz
@DavinderSingh-xs5uz 4 ай бұрын
Thank you so much. Brilliant video 👍
@MWPHS
@MWPHS 4 ай бұрын
Glad it was helpful!
@bartoszborowiak0304
@bartoszborowiak0304 4 ай бұрын
Hi Rich, This is brilliant video. I have a question about the EvoHome system. I'm currently using gas boiler with 10 HR924 + HR91EE. I'm planning some renovation works and one zone will be gone with extension where underfloor heating will be in place (part of the house) - the remaining radiators are still there. Can I add the HCC100 to the system? Your help will be much appriciated.
@MWPHS
@MWPHS 4 ай бұрын
So yes, you can add the HCC100 but you will only have the remaining zones on the evohome controller to use, not the full 8 zones the HCC100 offers.