Honeywell Home evohome | Creating a single heating zone with evotouch Controller as the thermostat

  Рет қаралды 16,065

MWPHS

MWPHS

Күн бұрын

Richard from The Smart Thermostat Shop.co.uk talks through how to create a single heating zone using the temperature sensor in the evotouch Controller.
Part 2 of our Honeywell Home evohome setup series is here - • Honeywell Home evohome...
Honeywell Home evohome can be bought online from our shop - thesmartthermo...
If you have found the video useful, please Like, Subscribe or even buy us a coffee - paypal.me/buym... :)
If you require any technical support with Honeywell Home evohome, please contact the Resideo Technical Support Helpline on 0300 130 1299 and select Option 3.

Пікірлер: 32
@tompreaney
@tompreaney 2 жыл бұрын
helpful, thank you
@Uk2pakistanonbus2024
@Uk2pakistanonbus2024 3 ай бұрын
Hello everybody, can I run to Boiler thermostats with one controller?
@Barrysailing
@Barrysailing 2 ай бұрын
Hi Richard, great videos thanks. I would like to use my EVOHome controller to act as a room thermostat for the room it is locate in, but can't find how to do this. Can you advise please? Yes it is in the same room which has two radiators, both with HR92s
@MWPHS
@MWPHS 2 ай бұрын
Is the room it’s located in controlled by a HR91 or HR92 radiator controller?
@barrydyer4560
@barrydyer4560 2 ай бұрын
Yes it is in the same room which has two radiators, both with HR92s
@MWPHS
@MWPHS 2 ай бұрын
@@barrydyer4560 when you setup the zone you choose to use the internal sensor in the evotouch controller rather than the HR92 as the sensor. Contact Resideo/Honeywell Home on 03001301299 if you need support.
@bartolomeoliguori2000
@bartolomeoliguori2000 Жыл бұрын
Hello Richard, thank you for the great video. I have a question: if i have for the same room more than one heating radiant panel, what can i do? E.G. I have a big leaving room with 3 radiant panel. how to make this as one zone? thank you for your feedback. BRs, Bartolomeo
@MWPHS
@MWPHS Жыл бұрын
When you bind the BDR91 you can bind 3x BDR91 at the same time by putting them all into bind mode at the same time.
@porcusorulisteric6951
@porcusorulisteric6951 2 ай бұрын
Hello! I have 1 evohome controller and 5 hr92 radiator valves. Can i place the evohome controller in a room with no radiator valves and use the internal sensor to start the boiler for that room and the rest will strat the boiler from the radiator valve? Or i need 6 radiator valves? Thank you
@MWPHS
@MWPHS 2 ай бұрын
Unfortunately the system doesn’t work like that. If you are smart zoning, you need them on each radiator as they control the flow of ‘energy’ to each radiator if that makes sense?
@marekc8654
@marekc8654 3 ай бұрын
Hi. Are they any other relay units that evo home can conect to.
@MWPHS
@MWPHS 3 ай бұрын
No, just the BDR91 or the R8810A OpenTherm Bridge.
@waynemountford9656
@waynemountford9656 Ай бұрын
Hi can you have 2x HR91 in one room?
@MWPHS
@MWPHS Ай бұрын
Yes you can. 👍🏻
@EvgenyVizelman
@EvgenyVizelman Жыл бұрын
I have an Immergas hydronic boiler, currently on a Siemens thermostat. I also have a Panasonic ducted air conditioner, on a Panasonic controller (two core cable). Is there some way I could have both these units controlled through the evohome? I'd like them to be smart and wifi controllable, but also don't want to have two separate controllers. Thanks!
@MWPHS
@MWPHS Жыл бұрын
Potentially you could create an ‘electric heating zone’ comprising of a thermostat and relay box within an evohome system and this will run independently. Only problem you would have is evohome is a heating controller and cannot do cooling in the manner I suggest (logic would be reversed).
@drhamerahussain
@drhamerahussain 3 ай бұрын
cs92a two of the rooms have egg timers . how do i set the temp via the t87 also please ?
@MWPHS
@MWPHS 3 ай бұрын
Have you changed the batteries in the CS92A?
@drhamerahussain
@drhamerahussain 2 ай бұрын
@ yes battery changed . It’s just one of the rooms now
@EtienneL-it2gp
@EtienneL-it2gp 9 ай бұрын
Nice video ! Do you know if the Evohome and HM80 can control the main mixing valve of my installation (not only for a zone) ?
@MWPHS
@MWPHS 9 ай бұрын
Hi, evohome and a HM80 (if you can find one) controls mixing at zone level only.
@EtienneL-it2gp
@EtienneL-it2gp 9 ай бұрын
@@MWPHS Ok. That means it is impossible to configure the Evohome to control the 3 way mixing valve depending on the whole house demand ?
@MWPHS
@MWPHS 9 ай бұрын
@@EtienneL-it2gp why would you have a mixing valve controlling the whole house? A mixed circuit is usually part of more than one zone where the temperature to the one circuit is higher than the second circuit (1x radiator circuit and 1x UFH for example).
@EtienneL-it2gp
@EtienneL-it2gp 9 ай бұрын
@@MWPHS The main 3-way valve makes it possible to precisely adjust the water temperature of the whole circuit according to the needs of the radiators. My installation was designed like this.
@MWPHS
@MWPHS 9 ай бұрын
@@EtienneL-it2gp ok, well evohome is not designed to work like this unfortunately.
@Uk2pakistanonbus2024
@Uk2pakistanonbus2024 3 ай бұрын
Sorry, I forgot to mention I got two valiant boilers need to run together example one Boiler Upstairs and one Boiler for downstairs
@MWPHS
@MWPHS 3 ай бұрын
Unfortunately, you cannot run two boilers with one evohome Controller.
@MaikelvandenWildenberg
@MaikelvandenWildenberg 2 жыл бұрын
Good video! Can you make a video using 2 BDR91T? One for cooling and one for heating? I have a Daikin Altherma 3. I think that I need to use 2 pieces for this, but I don't know for sure yet.
@MWPHS
@MWPHS 2 жыл бұрын
Yes no problem I will work on this next week. Just to note that the two relay configuration for heat pumps is just specifically for ‘heating/cooling changeover’ and the heat pump must have this functionality for it to work.
@Uk2pakistanonbus2024
@Uk2pakistanonbus2024 3 ай бұрын
Hello everybody, can I run to Boiler thermostats with one controller?
Гениальное изобретение из обычного стаканчика!
00:31
Лютая физика | Олимпиадная физика
Рет қаралды 4,8 МЛН
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
Vloerverwarmingspomp aansluiten op een Honeywell HCE80..
2:42
John Visser cv-optimalisatie
Рет қаралды 4,9 М.
Wasco instructiefilm | Evohome Touch
5:42
Wasco Groothandel
Рет қаралды 40 М.
Why This Window Heat Pump Is Genius
13:24
Undecided with Matt Ferrell
Рет қаралды 1,2 МЛН
Explaining the BDR91 Boiler Relay LED indicators - Resideo
2:51
Resideo Customer Support
Рет қаралды 99 М.
Project installatie - HCC100 Multizone Vloercomfortregelaar
13:15