Ko dail nya taro di plat kalau pelat nya melengkung , taro di tiang atuh bosku
@hunartaha830 Жыл бұрын
placing dial gauges on this plate is mistake
@kanarajan Жыл бұрын
Yes it is not recommended at all the occasions; the test load should be checked
@hunartaha830 Жыл бұрын
the main girder is very small
@kanarajan Жыл бұрын
I think, u couldn’t judge the dimensions of the girder by looking this video, but it’s successfully done and sufficient
@kanarajan Жыл бұрын
I think, u couldn’t judge the dimensions of the girder by looking this video, but it’s successfully done and sufficient
@kanarajan Жыл бұрын
I think, u couldn’t judge the dimensions of the girder by looking this video, but it’s successfully done and sufficient
@kanarajan Жыл бұрын
I think, u couldn’t judge the dimensions of the girder by looking this video, but it’s successfully done and sufficient
@azardeen17053 жыл бұрын
If can reply me, I'll give my email
@azardeen17053 жыл бұрын
Can I have a specification of laterals load test and it's method statement
@kanarajan3 жыл бұрын
Please refer ASTM
@azardeen17053 жыл бұрын
Hi bro
@Moseidon5023 жыл бұрын
How many people are involved in this load test ?
@JatiragaChannel4 жыл бұрын
to analyze the reading results of the Static loading Test, please stop by my Chanel, kzbin.info/www/bejne/goK6p6CuYr6tos0
@ikhsanprayogafull4 жыл бұрын
Good Job ikhsanprayoga.blogspot.com/2020/09/loading-test.html?m=1
@TEMELTASCONSTRUCTION4 жыл бұрын
Good job
@kanarajan4 жыл бұрын
TEMELTAŞ CONSTRUCTION thanks dr
@wuhansinorocktechnologyco.7184 жыл бұрын
Is it only necessary to purchase software and sensors?
@kanarajan4 жыл бұрын
I don’t understand; what do you mean ? ; no special software is needed ,
@Satyabansahoo5 жыл бұрын
Can you provide your contact number please
@kanarajan5 жыл бұрын
you can contact via +94764144743
@Satyabansahoo5 жыл бұрын
What the design load of this pile. & Jack capacity
@kanarajan5 жыл бұрын
the factored load was around 6500 kN for this test, jack around 10000kN
@user-ds4kd4eh9q5 жыл бұрын
Which gives best result static pile load test or dynamic pile load test
@kanarajan5 жыл бұрын
static load test is the best for measure the actual settlement. But the dynamic one is easy, low cost and quick one. skin friction and end bearing values can be evaluated separately through the PDA. Also PDA used for comment abut integrity of pile. static load test is only for settlement measurement while loading. So, it is based on your requirement dear friend.
@user-ds4kd4eh9q5 жыл бұрын
@@kanarajan thanks
@Ator-oq3tt5 жыл бұрын
Buat vidio ni biar pnjang smpai hbis ni sepruh jln je adoi.
@kanarajan5 жыл бұрын
Sorry, I couldn't get idea about your language.
@nurimarasofea83205 жыл бұрын
Nk panjang, buat sendiri la sengal, 5 jam pun blh
@kanarajan5 жыл бұрын
@@nurimarasofea8320 I'm sorry, i couldn't get you.
@fabianab83205 жыл бұрын
kanarajan They are trying to say that they would like to watch a longer video on the building process
@kanarajan5 жыл бұрын
@@fabianab8320 thanks dear for the translation.. full process takes around 1 - 1.5 hrs(excluding the shifting of launching structure). So it is much long video clip. I don't have actually. it was taken as clips only considering important steps of the procedure.
@motionicsllc5 жыл бұрын
Great Demonstration for Static Pile Load Test.We really appreciate your efforts. We offer Wireless Pile Load Test Kit for taking the load readings on piles with 100% wireless. Our custom pile load test application allows you to get the readings of the graph on your smart device e.g smart phone or tablets. For more information, please visit our store: @t