Thank you so much great video and extremely helpful made my install much easier and faster!!
@javiercasanova592112 күн бұрын
Thank you for this video! I’ve been diving in the pool for years to reattach these. God bless!
@rolandocontreras6589Ай бұрын
That connection coming out of the ground doesn’t seem right. It might collect water when it rains.
@funonymousАй бұрын
Why were there like filters pumps and two filters? The pool you show looks far too small for that much equipment.
@DebraGaines-l9hАй бұрын
What if it's stuck and won't pop loose?
@timharriswАй бұрын
get rid of those 90 s and install sweeps
@dopemil2 ай бұрын
This is the best install video I have found on KZbin. Great getting to see the whole process without any cuts and I also appreciate that the commentary covered every little step and didn’t assume that we know anything. Also appreciated some of the “pro tips” along the way (like letting the glue dry , making those cuts to avoid the 45°s, covering the pump with the bag, etc.) that I haven’t seen any other tutorials mention. Great video, I’m feeling much more confident to install my own pump myself for the first time tomorrow. Thanks!
@nicholasalan62872 ай бұрын
Awesome!
@EvgeniyIreneMavromati2 ай бұрын
Hi, how do you connect IntelliChlor to this pump?
@TheCoolbreeze453 ай бұрын
At 3:07 what compound are you using for the air release valve?
@jeffreyra13503 ай бұрын
Apparently you don't realize that you need a 30" x 36" clear working space in front of the electrical panel. According to the National Electrical Code (NEC) Section 110.26, the working space in front of a 120/208 volt electrical panel should be at least 30 inches wide and 36 inches deep. This blatent code violation puts the homeowner ar risk as well as Aqua Pool. Thats why you don't hire non union scabs to do work. They don't care about codes designed to protect workers and the public.
@jperello0013 ай бұрын
Need at least 5x pipe diameter run before entering this pump. This will void that 3 year warranty. The instructions are in the manual
@stevojams3 ай бұрын
Great video. So you ran 2 2 pole breakers for vsf pump and jet pump separately? What if you have booster pump for sweep?
@victorjimenez17263 ай бұрын
Does this pump work with in floor cleaning systems?
@jmatthews72283 ай бұрын
Why did they go with the aqua link over just getting an intellicenter since everything is Pentair anyways?
@robertpenczar89303 ай бұрын
Damn you're good
@AquaPoolSupplyUSA3 ай бұрын
thank you!!
@jasonrazojazo3 ай бұрын
That looks expensive, over 20k.
@gregcarper4 ай бұрын
I didn't realize you could use DWV (Drain, Waste, Vent) PVC pipes on a high pressure pool pumps, is that lower connection a drain? DWV is limited to 5 PSI, I guess you got the dual marked DWV & Pressure kind that complies with ATSM/ D2665 / D1785 Pressure. Also just curious why you didn't add Sweep 90 degree Ells to gain some water flow efficiency? I am doing this same project right now and adding the sweeping 90 degrees to gain some flow efficiency. I ended up getting Waterway 411-9130 90 degree Elbows 2"S X 2"S Slip, I also got a Ryobi 2 inch 18 volt, PVC cutter, which made fast cuts and super smooth with no need for deburring, made the job so much easier. I think that pump generates 65 GPM in 2 inch config, which will be awesome! Some great tradecraft tips. I would have never thought to cut off the intake pipes and lower them. Nice job!
@Kfox19774 ай бұрын
If I want to hook up my salt system to the 5A max side, can I jump wires from main L1 and L2 over to the 5A L1 and L2 for supply? I have an Intelliflo now and they are both on my 220 gfci breaker in the sub panel, just the salt system goes into a manual timer prior to the salt power supply box. It seems this would make sense to keep both salt system and pump on the same breaker, just wired in the pump area now. Then out to salt supply box.
@Kfox19774 ай бұрын
If I want to hook up my salt system to the 5A max side, can I jump wires from main L1 and L2 over to the 5A L1 and L2 for supply? I have an Intelliflo now and they are both on my 220 gfci breaker in the sub panel, just the salt system goes into a manual timer prior to the salt power supply box. It seems this would make sense to keep both salt system and pump on the same breaker, just wired in the pump area now. Then out to salt supply box.
@nicholasalan62874 ай бұрын
🎉
@AquaPoolSupplyUSA4 ай бұрын
❤️
@garrettw37134 ай бұрын
Excellent video! What size wire is need to use from I/O board to the fireman’s switch? And can I manually turn on the heater if my phone isn’t with me to turn on with the app ? Thanks
@moussaahdoot16014 ай бұрын
Can you tell us how much cost for equipment and the job ?
@robertpenczar89304 ай бұрын
Good job my friend!
@AquaPoolSupplyUSA4 ай бұрын
Thank you! Cheers!
@humbertogayosso67554 ай бұрын
Nice clean work. I love seeing these videos, always learning something new.
@kidmikeygo46034 ай бұрын
What’s the benefit to the upgrade from eztouch panel? My screenlogic is shot and looking to get phone connectivity back, but don’t want to drop $700 for a shotty and out of date tech like screen logic again
@donguadalucio14054 ай бұрын
What is better, Aqualink or Intellicenter?
@befayenew35644 ай бұрын
Where did you find that flange you used to cover the hole for the gas pipe? I don't believe it comes with the heater, does it?
@jeanreneau74544 ай бұрын
Thank you for such a great demonstration. You did an awesome job.
@patriotsleepercell40605 ай бұрын
thid guy is an amatur
@CesarMartinez-km4uk5 ай бұрын
Baddd assss job... clean clean clean
@Holdall-wn7ke5 ай бұрын
First very clean install but a pain in the but to replace sections later or do maintenance. Since there are no unions(good thing, IMO) leave 8" between pipes to get a saw in and maneuver replacements. Also, should have removed lid and lubed(or confirm lube) o-ring , verified filter manifold not damaged and verified filters still secure.
@kensmall96705 ай бұрын
I'm trying to connect my Hayward AquaRite 900 to the IntelliFlo3 IO board. I'm taking a red and black wire from the SWG to the 16A Supply 1 and Device 1 slots on the IO board however the SWG is not getting any power when the pump is operating. The devise has been added to the program on the App and is enabled. What am I missing? Thank you!
@kensmall96705 ай бұрын
Figured it out!
@robertpenczar89305 ай бұрын
Another great video video you're awesome,
@AquaPoolSupplyUSA5 ай бұрын
You rock!
@alawialgumaee54665 ай бұрын
I have the same screen logic but I couldn’t connect the pentair app to it
@deionzadani63165 ай бұрын
Working on this exact situation tomorrow. 4/21/24 Would appreciate your help. When you are connecting the fireman switch to the automation card with the com cable, does it matter which wire goes on pin 1 and which goes on pin 2 of the 5 amp bar? Asking for a friend. LOL Thank you!
@DannyShugart5 ай бұрын
It doesn’t matter on that situation. All you’re doing is closing the loop for the fireman switch.
@nathansager83785 ай бұрын
Thank you very helpful video what usually the average charge for the installation
@robertpenczar89305 ай бұрын
Well sir I have to say you got the best freaking out there, Man you are so good
@robertpenczar89305 ай бұрын
Another great video video you're awesome, do you teach on job training by chance
@lannyvilensky22646 ай бұрын
Question how come during your installation of outdoor cables like EitherNet you never place in conduit. My background was a special equipment installer and have always protected exposed wires in a conduit to protect from weather, rats and accidental tripping by people. Thanks.
@jorgelopezcanales43476 ай бұрын
Saludos ! debiste haber cambiado los cables viejos , si cambiaste la bomba nueva !
@lannyvilensky22646 ай бұрын
Watching your video from the Philippines about installation of new upgraded Intellicenter 522048 Suggestion with all respect. Slow down and relax when working. You appear to be very knowledgeable but a bit to much caffeine. Please keep the info coming. Very helpful Again no disrespect just a suggestion from a viewer.
@PoolBoyRoy6 ай бұрын
BYPASS ??
@mikerossi50806 ай бұрын
Great video thanks for uploading... BTW can you tell me where I would connect my heat pump to the Easy Touch as I do not have a gas heater... Thanks
@ZacharyWood-rx9ox6 ай бұрын
Are you a certified installer?
@JonnieF147 ай бұрын
How much does something like this cost?
@AquaPoolSupplyUSA5 ай бұрын
Check it out here! aquapoolsupply.com/products/pentair-easytouch-psl4-control-systems-with-screenlogic-522355?_pos=1&_sid=9bb7e58ac&_ss=r
@andybrody7 ай бұрын
Great job! Question: pump is running off Aux 2 instead of Filter Pump on automation?
@JuanSanchez-tk4vr7 ай бұрын
Attach bonding wire, not grounding wire.
@scottb57267 ай бұрын
Great video just got mine installed with light and booster pump. Love it so far
@AquaPoolSupplyUSA7 ай бұрын
Thank you!! Congrats! I'm sure you're loving being able to control those things without having to install a separate automation system.
@rcintron236 ай бұрын
Gracias tenia una idea pero ahora me aclarastes .
@Leshka755 ай бұрын
Can this control valve actuators?
@mikedaflame84837 ай бұрын
So if you are powering a salt system how would it change?
@mikedaflame84837 ай бұрын
Nice install and great demonstration on how to make the pump even with the pipes. In addition when needed on some occasions. I use a reed tool to take the pipe out of the couple connected to the two way check valve if I don’t have enough length. But you definitely went above and beyond for this install.