LC UV Detector Issues
2:02
Жыл бұрын
Syringe Basics for Chromatography
3:30
LC Leak Checking
2:20
Жыл бұрын
Optimizing Split Injections
3:09
2 жыл бұрын
3 Ways to Reduce Your Helium Usage
3:35
What is SPME?
3:09
2 жыл бұрын
Optimizing Splitless Injections
3:40
Split vs. Splitless Injection
4:41
4 жыл бұрын
How to Store Reference Standards
1:50
Sonicating Your Reference Standard
1:29
10 Places to Check for GC Gas Leaks
3:57
GC Particle Traps
3:14
4 жыл бұрын
What is QuEChERS?
3:00
4 жыл бұрын
SPME Arrow Tips
2:11
4 жыл бұрын
Пікірлер
@Mandenga100
@Mandenga100 2 ай бұрын
You guys are explaining this so good. I use your video's to show my students about how to troubleshoot!
@RestekCorp
@RestekCorp 2 ай бұрын
Wow, thank you!
@okyoros
@okyoros 3 ай бұрын
Thank you for such wonderful explanation.
@kobedierckx2918
@kobedierckx2918 4 ай бұрын
Nice video! this is in my school materials, i could see what bleeding is on a graph but couldn't put it in the right words. Now i know that it is additional unwanted signals in the graph caused by the degradation of the stationary phase caused by a reactive chemical like a strong acid or base or by oxygen contamination so it is very important to filter for oxygen in the carrier gas.
@oliveoil6195
@oliveoil6195 4 ай бұрын
Hi, thank you for the video! Can you tell me a little bit about the difference between a fixed flow regulator and a variable flow regulator?
@al_musstafa5843
@al_musstafa5843 4 ай бұрын
Hello, how much is the value of the lamp based on its voltage?
@zahradashtbozorgi7469
@zahradashtbozorgi7469 4 ай бұрын
Thanks that was very helpful. Please make a video about maintaining the ECD detector. thanks
@jey8436
@jey8436 4 ай бұрын
After how many injections, (on average), should the filter be replaced? And what about cleaning the split vent lines?
@RestekCorp
@RestekCorp 4 ай бұрын
This can vary greatly. As a default, we'd always recommend checking with your instrument manufacturer's guidelines. These are generally around every six months. How much you are injecting, how much is your split, how dirty are your samples can all impact this. Cleaning split vent lines is generally reserved for a situation where you feel it is needed, such as seeing some ghost peaks or other evidence of contamination. In an extreme case, when you notice incorrect flow rates and may suspect some clogging.
@ronesoares6164
@ronesoares6164 5 ай бұрын
Obrigado
@ronesoares6164
@ronesoares6164 5 ай бұрын
Sou de São Paulo Brasil e trabalho com um cromatógrafo com duas colunas e quando injeto a mesma amostra nos dois, tem muita diferença no resultado, e sinal do fid do front e 6,2 e do back está em 7,8. vou fazer um vídeo e mostrar aqui nos comentários ok.
@ronesoares6164
@ronesoares6164 5 ай бұрын
Obrigado pela informação
@ronesoares6164
@ronesoares6164 5 ай бұрын
Muito obrigado amigo, moro em São Paulo Brasil, e trabalho com um cromatógrafo com duas colunas e uma está com o sinal (fid) muito alto, o front está com 6,2 e o back com 7,8, quando injeto a mesmo amostra nos dois, dá uma diferença, e também no final da corrida e sinal aumenta muito. Vou fazer um vídeo mostrando o ocorrido.
@2339091q
@2339091q 5 ай бұрын
Thank you so much!
@lorenzojercan1793
@lorenzojercan1793 5 ай бұрын
The blank must be the same as the mobile phase?
@sooncheongkwan9007
@sooncheongkwan9007 6 ай бұрын
Hi, can you show us how to replace the frit Agilent 1290 system?
@radi675
@radi675 7 ай бұрын
do you offer the split vent trap for shimadzu GC2030? The new design for 2030 is offered at hilariously outrageous $200/unit.
@RestekCorp
@RestekCorp 7 ай бұрын
Hello, I'm sorry, this is not a product that we offer. Thank you for asking!
@meme2403
@meme2403 7 ай бұрын
You talk about the initial oven temperature, does this mean that the separation was carried out in temperature programming mode? Tank you.
@RestekCorp
@RestekCorp 7 ай бұрын
Generally yes, but it doesn't need to be.
@amirrulhakim01
@amirrulhakim01 8 ай бұрын
Can you help me, the back detector shows temp not installed. And my infront gas (N2) flow rate i set is 45, but the screen show range 51 - 60. Can you help?
@technicalvinayak6959
@technicalvinayak6959 8 ай бұрын
*Make video on TCD*
@kalaimathim220
@kalaimathim220 8 ай бұрын
I have faced an ignition cut-off when the sample was injected. Upto injection of sample flame is on and shows a good signal. but when injected immediately, the ignition will cut. what is the reason? can you please tell me?
@RestekCorp
@RestekCorp 8 ай бұрын
What are you injecting and how much? You may wish to troubleshoot by trying to inject less or a different solvent. You can also do an no injection instrument blank to see if it is a timing/flow issue rather than the injection itself. You can find instructions on how to do that here kzbin.info/www/bejne/qqHIk4Oeq7Z4iLssi=DNIgtobWEzHsxpe3
@chakhonglam2444
@chakhonglam2444 8 ай бұрын
I have an Agilent ZORBAX NH2 and Carbohydrate column which is used for HILIC separation for sugar. Since those 2 columns have not been used for a period of time. Which solvents are suitable to use for cleaning and regeneration?
@RestekCorp
@RestekCorp 8 ай бұрын
For any specific column, we would always recommend referencing the original manufacturer's instructions. Here is some information that may be helpful www.agilent.com/cs/library/datasheets/public/820629-008D.pdf For general information on LC column regeneration, we have a nice blog post www.restek.com/chromablography/resurrecting-an-old-reverse-phase-lc-column--should-i-could-i-how-would-i
@mountfuji3330
@mountfuji3330 9 ай бұрын
Can you explain what's the purpose of the serrated edge, please? (Assuming there is a purpose).
@RestekCorp
@RestekCorp 9 ай бұрын
In the past, the serrated edge was recommended for use for cutting some smaller ID metal columns. Generally, even those are now recommended to be cut with the smooth edge.
@mountfuji3330
@mountfuji3330 9 ай бұрын
@@RestekCorp Thank you for the information.
@SasiKumar-lg1wc
@SasiKumar-lg1wc 11 ай бұрын
What is the makeup gas?
@SasiKumar-lg1wc
@SasiKumar-lg1wc 11 ай бұрын
Whis is mechanisms of FID detector
@Dr.AmzadHossain
@Dr.AmzadHossain 6 ай бұрын
Could you please make a complete video for working Software and analysis details step by stem
@SasiKumar-lg1wc
@SasiKumar-lg1wc 11 ай бұрын
How to remove the flowcell contamination?
@SasiKumar-lg1wc
@SasiKumar-lg1wc 11 ай бұрын
What is difference between RI,PDA,Uv dectors
@SasiKumar-lg1wc
@SasiKumar-lg1wc 11 ай бұрын
How to reduce the column back pressure?
@SasiKumar-lg1wc
@SasiKumar-lg1wc 11 ай бұрын
Which solvent suitable for c18 columns?
@SasiKumar-lg1wc
@SasiKumar-lg1wc 11 ай бұрын
How to remove the column blockage?
@HenoMarkarian
@HenoMarkarian 11 ай бұрын
Can one extrapolate two neighbor peaks with resolution below 1.0? Is it correct to integrate the area of extrapolated peaks that are artificially deconvoluted?
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
Pl.tell about collector assembly sir
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
What is the principal behind FID Jet
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
How to clean the FID jet and how to know jet is damaged,?
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
Good Explanation sir.
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
What is the minimum syringe injection volume during method optimisation
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
We are use mostly Exmair syringe.After 100 injection , syringe response wasn't good.What is the best syringe and rugged
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
What basis syringe(10 micro or 5 micro litre) to be chosen based on injection volume 1 micro litre
@thilpanneerpanneer2327
@thilpanneerpanneer2327 Жыл бұрын
Why syringe is struck after 8 injection of DMSO mostly
@ArchanaBhamre-gp7ii
@ArchanaBhamre-gp7ii Жыл бұрын
Thank you for ur guidance ...it's really helpful...thank you...sir
@Icyblaze...
@Icyblaze... Жыл бұрын
We got solvent peak but no sample peak. Any advice for this? Thanks! Appreciate your assistance.
@hidayahsharin7453
@hidayahsharin7453 Жыл бұрын
I also encounter the same issue.
@yohandudognon4108
@yohandudognon4108 Жыл бұрын
What about chemicals with labile hydrogen such as carboxylic acid due to the column ? Is there a way to avoid peak tailing ?
@RestekCorp
@RestekCorp Жыл бұрын
Compounds like carboxylic acids, can be very difficult to get good peak shapes. Depending on the column phase, there may be columns specifically designed to work with acids that can help. Stabilwax-DA columns are an example. Derivitization is also used for some compounds to improve peak shapes - fatty acids are often methylated before being analyzed for this reason. Some analysts also do priming injections - injecting high concentration standards to help occupy active sites before doing their analytical injections. There are many options, but they can all have their pros and cons.
@quimicamentefalando
@quimicamentefalando Жыл бұрын
Congratulations for the video, but I don't understand how a pulsed split injection can have the liner with increased pressure if the injector outlet opens?
@RestekCorp
@RestekCorp Жыл бұрын
The pressure controls of the GC system are designed to handle these pressure changes. So while there is still flow going through the column (and out the split vent, septum purge, etc.) pulsed injection allows users to temporarily elevate the pressure in the injection port.
@quimicamentefalando
@quimicamentefalando Жыл бұрын
@@RestekCorp Great! Thank you for this.
@RestekCorp
@RestekCorp Жыл бұрын
You're welcome!
@salve1185
@salve1185 Жыл бұрын
sir why do you need to cut the column? what is the purpose of cutting a column?
@franleblanc
@franleblanc Жыл бұрын
Came to watch how to properly re-install the collector assembly. I also am having a hard time.
@alahamomand33
@alahamomand33 Жыл бұрын
I am studying for my Chromatography course and this video was literally so well made. Thank you!
@dhirenkc6748
@dhirenkc6748 Жыл бұрын
Hi sir, In case of benzene in carbomer as per USP method ... the benzene standard getting deterioration after 1 or 2 injections through splitless mode where i have been connected with split line in the GC...is this problem are having connection with split liner...
@ameno0224
@ameno0224 Жыл бұрын
Could anyone recommend me packed column can separate oxygen, nitrogen and CO to tcd?
@destinyhagendorfer-is8no
@destinyhagendorfer-is8no Жыл бұрын
Where can I get the cap for the septum purge?
@RestekCorp
@RestekCorp Жыл бұрын
That will depend on your instrument. Many can use standard compression fitting caps, but you should check your instrument manual or instrument manufacturer to be sure.
@user-gf6mt3bd4k
@user-gf6mt3bd4k Жыл бұрын
I'm careful if I can ask here, but is it possible to analyze isophthalic acid by GC-MS? I have been having a tailing problem for a month. I will buy all the products you recommend. Somebody help me T^T
@maracchi2046
@maracchi2046 Жыл бұрын
Tailing happens when the analyte of interest retains in the column. How the oven is programmed, gas flow rate, or the column used could impact your acid. You might need to look into different columns since you are dealing with aromatic acids, like Chromaton N-AW-HMDS with 5% Apiezon L column.
@user-dk7nb3dm4y
@user-dk7nb3dm4y Жыл бұрын
Each video is too short,Can some long videos provided to explain the details?