Modern Home Build Project
4:51
28 күн бұрын
3462 Dewberry Ln Macedon NY 14502
4:44
200 Amp Service Feed To New Home
8:05
Day One Of Framing A New House
3:06
Пікірлер
@96thundercat
@96thundercat 3 күн бұрын
Dope, tape, dope? Interesting 😊
@davepelfrey3958
@davepelfrey3958 3 күн бұрын
Big beautiful and simple. Absolutely love it.
@leonardom2613
@leonardom2613 4 күн бұрын
You are absolutely right. The money money diference in that pump is nothing compared with the benefits.
@armandogomez2677
@armandogomez2677 5 күн бұрын
I have a boiler,baseboards heaters and a hot water tank. Can one of these replace the boiler and hot water heater ?
@JimSperanza
@JimSperanza 5 күн бұрын
@armandogomez2677 Absolutely! Email me at [email protected] if you are interested in a system.
@GetToThePointplz123
@GetToThePointplz123 5 күн бұрын
How thick is the steel?
@JimSperanza
@JimSperanza 5 күн бұрын
@@GetToThePointplz123 1/4" (3-Pack) Countertop Support Bracket,Top Mount,Solid Heavy Duty Knee Wall Hidden Granite Countertop Support Floating Shelf Bracket,Shelf Bracket Hardware,Set of 3,15 Inch,DIY Projects,Screws Included a.co/d/9xIWFSU
@qualitybydesign5119
@qualitybydesign5119 6 күн бұрын
Was rebar required and placed in the footer ? About how many inches of the form are exposed and need to be flashed on the exterior ?
@JimSperanza
@JimSperanza 6 күн бұрын
Rebar was placed into the footer. I typically use a 6 inch steel flashing then backfill to keep about 4 inches exposed which gives a nice clean look.
@qualitybydesign5119
@qualitybydesign5119 6 күн бұрын
Thanks for the quick response ! Are you a general contractor/builder ? Your quite knowledgeable about all facets of your build .
@JimSperanza
@JimSperanza 6 күн бұрын
@qualitybydesign5119 yes Speranza Development LLC. I offer designs and consulting services for residential builds.
@mike270
@mike270 6 күн бұрын
Where is the tt terminal on this boiler ? where you would connect the relay
@JimSperanza
@JimSperanza 6 күн бұрын
@@mike270 The TT terminals are the zone 3 thermostat connection. The manual shows this detail.
@floridaman197
@floridaman197 6 күн бұрын
You need a tool that will bond a metallic box that is isolated by PVC conduit.
@JimSperanza
@JimSperanza 6 күн бұрын
@floridaman197 the box is also PVC
@floridaman197
@floridaman197 6 күн бұрын
Damn! I looked really close and I stand corrected. I need to turn in my damn Klines!
@JimSperanza
@JimSperanza 6 күн бұрын
@floridaman197 😄
@bogartchu7616
@bogartchu7616 8 күн бұрын
What model are those all black sinks? Experience with durability of them like scratches/hard water. Everything looks really nice.
@JimSperanza
@JimSperanza 8 күн бұрын
@bogartchu7616 32" Blanco Precis in Coal Black and the small bar sink is 10x18 in a 15" cabinet that I found on Amazon.
@qualitybydesign5119
@qualitybydesign5119 9 күн бұрын
Where is this house located ? Just wondering what form size is required for what climate zone.
@JimSperanza
@JimSperanza 9 күн бұрын
Rochester NY
@Offgridinmaine
@Offgridinmaine 9 күн бұрын
Good stuff. Can you provide a link? Also what is the frost line in Rochester? I’ll be in Northern Maine. Line is 72”
@JimSperanza
@JimSperanza 9 күн бұрын
@Offgridinmaine They make an Artic form for your application. Mono Slab EZ Form (208) 558-5200 g.co/kgs/r4xvWDu
@trevorj203
@trevorj203 10 күн бұрын
What was the point of this video to waste peoples time
@mattpotter2148
@mattpotter2148 10 күн бұрын
What was the name of the sealer you used? Thank you
@JimSperanza
@JimSperanza 10 күн бұрын
@@mattpotter2148 D-One sealer
@Hazy5498
@Hazy5498 11 күн бұрын
Very nice
@aleahsperanza7415
@aleahsperanza7415 11 күн бұрын
Hi! What did your total cabinet cost come to for this design (including the Butler's Pantry cabinets)!?
@JimSperanza
@JimSperanza 11 күн бұрын
About $9,000
@kirkhemmings8234
@kirkhemmings8234 11 күн бұрын
Perfect love everything you have good taste
@JimSperanza
@JimSperanza 11 күн бұрын
@@kirkhemmings8234 🙌
@thinde88
@thinde88 11 күн бұрын
Could you talk anymore about the ikea cabinet experience? Ordering? Price? How they were to build? Any tips or tools you’d recommend? I’m thinking of going this route as a DIY for my new build.
@JimSperanza
@JimSperanza 11 күн бұрын
@@thinde88 kzbin.info/www/bejne/fIW9lYuhltGZrKssi=Rhc50FvGCirZhJYg
@drewfullhart1750
@drewfullhart1750 12 күн бұрын
Why not just mount a switch inside the cabinet like a normal person?
@JimSperanza
@JimSperanza 12 күн бұрын
What is a normal person?
@VictorHoyos-j5e
@VictorHoyos-j5e 13 күн бұрын
are those dieletric unions on the manifold? is that manifold considered a closely spaced T? thanks and have a great day
@JimSperanza
@JimSperanza 13 күн бұрын
Yes and yes. Email me at [email protected] if you need help with a design.
@VictorHoyos-j5e
@VictorHoyos-j5e 13 күн бұрын
awesome stuff thank you
@leonginorivera8309
@leonginorivera8309 13 күн бұрын
Great installation loops , I love it .
@granttruckey6270
@granttruckey6270 15 күн бұрын
I'm doing the exact system you have here single zone 4 loop, except it's a closed system with an axiom feeder. Have you done any? And do you just cap iff the built in water connection? Also on the domestic cold side do you have a back flow valve? BTW great vids
@JimSperanza
@JimSperanza 15 күн бұрын
@granttruckey6270 use the auto feeder much easier to fill the system. Backflow preventer goes on the auto feeder not on the domestic cold.
@Your_FYP_slay
@Your_FYP_slay 15 күн бұрын
Looks amazing
@rayshaunjustice1988
@rayshaunjustice1988 18 күн бұрын
They break down pretty often in the hotel I work in. But it seems they work great in boiler systems and not individual heat pumps in each room. We replace these actuators at 3 times a week.
@bergan1227
@bergan1227 19 күн бұрын
Great looking system I’m stuck using electric do you have any suggestions on a boiler or Tankless hot water heater. heat only
@shinymetalobjects
@shinymetalobjects 20 күн бұрын
how wide is that hallway?
@JimSperanza
@JimSperanza 20 күн бұрын
@shinymetalobjects 42" but the wide angle lens makes it look really skinny.
@frank69chv
@frank69chv 20 күн бұрын
Would I need a second return pump for a single zone 3200 sqft 6 loop setup?
@JimSperanza
@JimSperanza 20 күн бұрын
@@frank69chv you only need 1 pump per zone. Email me at [email protected] if you'd like me to design you a system.
@Septix
@Septix 21 күн бұрын
Out of curiosity is it possible for the I Joists to support the roof without that middle wall you guys added? Or would it be too much in snowy areas like NY or WA? I imagine the will will help a lot with heavy loads but curious on how necessary it is, I imagine the layout would look fantastic if it was fully open but then again waste of space to some
@JimSperanza
@JimSperanza 20 күн бұрын
@Septix yes the main living room and kitchen is full span. The joists are all the same height throughout to keep the roofline the same but some are a "lighter" series that use the laod bearing wall to save some money.
@Septix
@Septix 19 күн бұрын
@@JimSperanza awesome, thinking about a similar build to this in the cascade mountains so will probably reach out to you for consulting once I finally hit the ground running. Many thanks!
@JimSperanza
@JimSperanza 19 күн бұрын
@Septix email me at [email protected] when you need me!
@rioborzeli147
@rioborzeli147 21 күн бұрын
👏Pride in workmanship all the way . Wish We had you install our Navien Combi system . Artwork is what you offer , We did not get anything like your video at all, our gas line is hanging freely by a pipe hanger 😭
@JimSperanza
@JimSperanza 21 күн бұрын
Sad to hear this but I also have helped many many people like yourself to get your system back on track. Email me at [email protected] if you would like me to assess your system and see if anything should be corrected.
@kellytomlinson8781
@kellytomlinson8781 21 күн бұрын
This thing sucks! Not only does it leave burrs but it also bends the last three threads at an angle. W have to use a demurring tool or recut multiple times. We have a used one and a brand new one and it does precisely the same thing. I've tried it flat on the ground but we bought it for making cuts in the air and it does not work. It does cut great but good luck getting a nut on the end you cut with the thing.
@JimSperanza
@JimSperanza 21 күн бұрын
@kellytomlinson8781 that's odd. Mine works great 90% of the time. Every so often it does leave a burr at the end but doesn't bend the threads. I assume you changed the dies but if your having the problem on both of them that does seem strange.
@Dykhopper
@Dykhopper 21 күн бұрын
new boiler....problem..hydronic system, zone 2 gives no heat when called for, zone 1 gets too hot....how to fix this???
@JimSperanza
@JimSperanza 21 күн бұрын
@@Dykhopper email me at [email protected]
@hex0rz1
@hex0rz1 22 күн бұрын
It's been a year later, are they still worth it?
@JimSperanza
@JimSperanza 22 күн бұрын
@@hex0rz1 absolutely worth every penny
@anthonyiengo183
@anthonyiengo183 23 күн бұрын
Where are you located
@Fabricationweld
@Fabricationweld 25 күн бұрын
Me losing ten pounds in the morning 😂
@JimSperanza
@JimSperanza 25 күн бұрын
@@Fabricationweld 😆 🤣 😂
@williamserver4332
@williamserver4332 25 күн бұрын
Do those circulators have to have IFC valves? Great video
@JimSperanza
@JimSperanza 25 күн бұрын
Yes if there is more than 1 zone pump you'll need them.
@williamserver4332
@williamserver4332 25 күн бұрын
@JimSperanza the way I understand an IFC is it opens when the circ pump turns on . How does water go through the pump when purging? Does water pressure from the auto feeder open the IFC to purge? Thanks
@JimSperanza
@JimSperanza 25 күн бұрын
@williamserver4332 yes it's literally just a simple one way check valve that pops into the circulators opening.
@williamserver4332
@williamserver4332 25 күн бұрын
@@JimSperanza Thank you. If you had only one zone wouldn't an IFC be needed to prevent heat from rising throughbthe house by gravity?
@JimSperanza
@JimSperanza 25 күн бұрын
I always install them even in single zone systems
@andrew1898
@andrew1898 25 күн бұрын
A new door in a haunted house? 😂😂
@stephanie.sammons
@stephanie.sammons 26 күн бұрын
Do you plan on using that thermostat permanently? I have 3 zones on my new NCB-240/130H, and trying to learn what programmable and/or smart thermostats are compatible. Any other brand recommendations or ones to avoid?
@JimSperanza
@JimSperanza 26 күн бұрын
Yes I use tekmars mostly for all my builds.
@johnnywyskiel
@johnnywyskiel 26 күн бұрын
The IF/AND statement thing is pretty neat. I have a few Kasa TP Link switches too, and didn't know that was a thing.
@JimSperanza
@JimSperanza 26 күн бұрын
@@johnnywyskiel it's under the smart tab called smart actions
@Hazy5498
@Hazy5498 26 күн бұрын
Very nice
@BigJon9595
@BigJon9595 27 күн бұрын
That thing is hingebound for sure
@andrew1898
@andrew1898 25 күн бұрын
Ahh just spray it with some white lithium WD and hope they don't notice till the warranty runs up
@BigJon9595
@BigJon9595 25 күн бұрын
@ exactly
@nmpwolf9679
@nmpwolf9679 25 күн бұрын
Sounds like they forgot to tape off the hinges before they paint it black like the rolling stones.
@erwinperez2889
@erwinperez2889 27 күн бұрын
We're do you hook up the fresh water in the system?
@JimSperanza
@JimSperanza 27 күн бұрын
@@erwinperez2889 there is an auto fill connection on the bottom.
@frank69chv
@frank69chv Ай бұрын
Hey I'm really curious how this setups been working ? I notice this is about the only one I've seen where the air eliminator is not mounted at a higher point. Reason I'm asking is because I'm wanting to do the same for easier plumbing. Thanks
@JimSperanza
@JimSperanza Ай бұрын
The air separator can be placed anywhere, it can even be the lowest component and not have any negative affect. However, its purpose is not to purge the air from the system during startup. Its function is to "scrub" the micro bubbles that remain within the system to assist with long term corrosion, or damage protection.
@silasseppala4459
@silasseppala4459 Ай бұрын
How do you run the wiring for the zone valves? Do you have one wire going from thermostat to the valve. And another wire going from the valve to the boiler?
@eddyvideostar
@eddyvideostar Ай бұрын
To Jim, Which video is the piping?
@richiewilde1621
@richiewilde1621 Ай бұрын
If I have in floor heat in my garage (in the concrete floor) and I take square footage x(times) 40btu and I come up with 55,680 btu total with 14.5’ high ceiling and in mid Michigan. Walls are 4.5”-5” blown in isolation. I am debating between 90,000 and 120,000btu modulating/condensing boiler , is the 120k over kill? I keep garage at 70 degrees
@JimSperanza
@JimSperanza Ай бұрын
@richiewilde1621 120k may be overkill....however a modulating boiler will be able to adjust its output. It will only cost a few more bucks to front for the bigger one
@epicgamer3694
@epicgamer3694 Ай бұрын
@johnhondrogen7630
@johnhondrogen7630 Ай бұрын
You do some stunning work! I really enjoy your videos.
@wirewaykingelectric4978
@wirewaykingelectric4978 Ай бұрын
If you actually sized your pull box correctly you wouldn’t need it
@JimSperanza
@JimSperanza Ай бұрын
Thanks!
@tlndresearch3037
@tlndresearch3037 Ай бұрын
Can you build me a "Pre-Built Combi Boiler System" for attic installation to cover a 30' x 22' floor space (13' slanted wall height)? Can you use PEX & Quick Connects wherever possible to eliminate metal piping and connections? Let Me Know
@JimSperanza
@JimSperanza Ай бұрын
Email me at [email protected]
@DanSjogren-b3i
@DanSjogren-b3i Ай бұрын
Wanted to take a minute and thank Jim and write a review. I just finished installing a combi system that I had Jim design for me, I think back in June. The drawing was great, the parts list was perfect and when I finally got it up and running he helped me through some questions and issues specific to my situation. Working perfectly! I built my own place, off grid, high elevation. Had a great plumber who then went crazy with hourly extras after the rough. I couldn’t afford those shenanigans so I took this on, way out over my skis. So, it took a while! But with the plans and the videos I was able to get it in and done successfully. Very very excellent drawings, guidance and assistance. Highly recommend!
@JoelLopez-md5es
@JoelLopez-md5es Ай бұрын
The one how many sqft I own three bedroom houses with a finished basement
@nieldcreek2098
@nieldcreek2098 Ай бұрын
What lbs did you torque the spacer? Do you have a link to the ott? Thanks