My ACS880 VFD shows the alarm check connection but everything is normal and so good so far.pls help me
@alirezakazeminiАй бұрын
Hello, that error appears for some other possibilities also. You will need to go through diagnostic steps. I have no time but contact me by insta or whatsapp let’s see.
@basvandenboogaard81378 ай бұрын
Thanks for the video! I have a question, I have a ACS880-01 and I want to connect to the EFB Modbus RTU. From my PLC, do you have an explanation on how to get the right register address that I want to read or write? My experience with Modbus = 0, so any help is appreciated.
@mohammadzaid5375 Жыл бұрын
Can I connect this drive to relay module of fire alarm for tripping the motor on receiving fire alarm signal ?
@alirezakazemini Жыл бұрын
Hello, sorry for late reply. Sure you can do that. Just consider Alarm and Interlock are different, Alarm will need resetting, Interlock doesn't need resetting. And both of them give you chances for NC or NO triggering. So you can apply any SOP scenario for a fire alarm.
@MuhammadUsman-wx5fq Жыл бұрын
Please explain vedio share
@youssefaboumalik9083 Жыл бұрын
thank you for video i want to try the same thing but in the communication setup did you put one rs485 link in com1 setting.
@alirezakazemini Жыл бұрын
Yes, you will set only com1 and the rest is while you write the tag address you define the device address which we normally don't. So this way you will show that the PLC address may not be always 1.
@muhammadwaseem2187 Жыл бұрын
@alireza kaemeni can you please share ur mail i need some help on ach580
Hello Good time I intend to network 13 580 inverters with Madbas with 2 delta plc by dlink. How do I read or write information now?
@alirezakazemini2 жыл бұрын
Are you going to have a redundant plc in your network and 13 inverters in one serial communication? contact me through WhatsApp maybe I can help you with TeamViewer also. +90 536 471 54 64
@AsifAli-tp5zo2 жыл бұрын
Aoa sir we have a abb vfd ACS880-250kw we faced a problem Pu communication fault 5681 Sir can you tell how to fix it
@alirezakazemini2 жыл бұрын
this error appears when there is no connection between the control side and the power side of your driver. I need the code and the serial number of your Driver. how old is it? you need to check whether the controller is faulty or it's the communication shield or the connector cable. is the driver wall mount type? if the connection is fiber optic and its age is more than 4 years I recommend changing fiber cables. If this info is not enough send me pictures on my WhatsApp at 0090 536 471 54 64
@WeconTechnology2 жыл бұрын
looks great!
@tylerpitts61582 жыл бұрын
This is such a great video, we were having trouble until I came across this video. Thanks so much for taking the time to go through controlling via Modbus RTU! Thanks!
@vikasyadav4970 Жыл бұрын
Super sir
@icemanb50652 жыл бұрын
Thanks for uploading this video. Somalia
@elhassanemargoum79552 жыл бұрын
Hello Alireza, First of all thank you for this great demonstration, I have a question regarding the access level. I would like to change the modbus RTU settings (address, baudrate...) but it doesnt give me access to edit. I have only one password (10000000). I think that there is a service password. I would appreciate it if you can help me on this Thank you!
@alirezakazemini2 жыл бұрын
Sure, may I know the name of your driver? you can share its pictures on my Instagram or Whatsapp
@gajendrapandey52022 жыл бұрын
@@alirezakazemini dear sir can we have your number because I’m facing some problems need your help
@sebastianstroe78142 жыл бұрын
Hello, what cable is between CPU and DC551-CS31 ?
@ninocule59853 жыл бұрын
Boss i have question my vfd.same model but frequency is not working. hand and auto whats is the solution? Now temporary working freq.input set to 40hz .
@alirezakazemini3 жыл бұрын
you cant change the frequency? contanct me in whatsapp 00905494153320 explain by photo, please
@youtubeyusuf65753 жыл бұрын
Hi, do you need to wire up I/O terminals even when you want to run a machine from control display/keypad attached to the drive? ( I don’t do any external control). I just connected 3 phase input and 3 phase motor connection.
@alirezakazemini3 жыл бұрын
No, just make sure your control source is on local and then push the green button.
@metinkara84883 жыл бұрын
🙏👏
@atemriaz1663 жыл бұрын
Very bade veido not helpful.
@alirezakazemini3 жыл бұрын
My friend, this video is not for learning Wecon programming. it is showing if you have PI3102 with only one serial port and you need to communicate with 2 PLC at the same time, what changes in the setup can make your wish come true.
@sadeghrivandi9913 жыл бұрын
با عرض درود مهندس من نیاز به یک دوره تخصصی اینورتر دارم، شما می تونید کمکم کنید ؟
@alirezakazemini3 жыл бұрын
Hello dear friend, if you are able to travel to Istanbul, maybe I can arrange a training.
@M1402au23 күн бұрын
@@alirezakazemini Alireza Jan ,Is there any other ways for training i can't travel to istanbul,مچکر از ویدیو عالی
@hasankeskin9773 жыл бұрын
Hi i want to control VFD like this : start and stop using from DI and DI2 and referance from Modbus For doing this :First I must to do Enable Embedded Fieldbus from 58 parameters then i must to chose Data I/O Output Frequency end the end i must to change AI Referance from Embedded Fieldbus Did I understand correctly ? If you help me i will be happy Thank you.
@alirezakazemini3 жыл бұрын
Yes, one of DI should be set to start by default but looks like you want to start and stop by pulse, so it's better to check the list of DI in I/O menu . You can also contact me through WhatsApp while setting your VFD. +90 549 415 3320
@alirezakazemini3 жыл бұрын
How to read frequency, current, voltage and so on from Modbus RTU? Watch the video from 10:23 , it is going fast, so I'm explaining what is happening. I'm reading Modbus registry list from 40001 to 40012. Addresses from 1 to 4 are set by factory, however you can continue this setting to get whatever you want in number 5 or 6 or whatever you choose here. Now pause the video at 10:44 , here I have set the address 40009 to show me frequency on 32bits integer. This is whey when I went for laptop it could show me frequency at address 9 You can different formats, I choose 32bit to get more accuracy. You can choose current instead of frequency. You can even choose something which is not parameter, from other lists. From the time 10:44 to 10:50 , 4 times I pushed exit button, by following this path also you can see how I set address 9 to show me frequency.
@MuhammadUsman-wx5fq17 күн бұрын
Please sir contact number share us❤
@mohabelsayed99963 жыл бұрын
Fantastic video...could u inform us how we can read current/ rpm/torque of motor through modbus rtu
@alirezakazemini3 жыл бұрын
Yes, I should accept that part of video is passing so fast. So better I explain what is happening at 10:23 of the video. I explain it as a new comment below the video
@BhupendraKumar-kb6vh4 жыл бұрын
Very informative, with the help of this video, I was able to commissioned my 580 drive. thanks again from California.
@alirezakazemini4 жыл бұрын
Your success is my pleasure
@chandramohanappajee60262 жыл бұрын
@@alirezakazemini hi sir.. I need your help for commissioning drive.. can I get your mail address or contact number that I can send you my abb drive issue
What parameters have to be entered by connecting ABB Acs 580 VFD to Pofibus?
@alirezakazemini4 жыл бұрын
In the complete list of parameters 58.01 Embedded fieldbus, you enabling a protocol, and depending on which protocol you choose corresponding setup will appear. Then you just need to set these communication parameters match with other device which is going to communicate with this VFD. Profibus also is a serial communication similar to modbus RTU
@patelkaushik29964 жыл бұрын
What parameters do you need to enter to connect to profibus in VFD 580 and what codes do you need to enter?
@alirezakazemini4 жыл бұрын
In the video only 20 seconds from the time 6:20 to 6:40 are about protocol parameters. Even these parameters are similar for all serial communications like modbus RTU ot Profibus. So if you planning to set your VFD for Profibus all your parameters will be the same as in this video. You can get more help if write me in which time of video you need more information
@MohamedAli-pc5dd4 жыл бұрын
Great Job!, i need to support for VFD integration MOdel ACH580
@alirezakazemini4 жыл бұрын
I will try to help
@MohamedAli-pc5dd4 жыл бұрын
@@alirezakazeminicould you please send test email, so that I will send you the details please
How to connect ACS880 drive to Pc through Fibre optic cable ? Does RUSB-02 DDCS adapter is compatible for communication? Which channel is used in FDCO-01 card for Drive composer communication through Fibre optic?? Com port numbers are not showing..
@alirezakazemini4 жыл бұрын
Yes, RUSB-02 DDCS adaptor can help but basic ACS880 suppor requires that you have the DriveDA OPC server (included in Drive composer pro) installed. DDCS communication protocol also is not available for ACS880. You can check working manual "DriveWindow 2 User Manual - ABB"
@amilcarmendoza15504 жыл бұрын
Great job!
@alirezakazemini4 жыл бұрын
Thanks!
@blazed4685 жыл бұрын
WoW ! How come apple s not fixing this
@alirezakazemini5 жыл бұрын
It happens only after you stop using your original charger