Hey man i watched a alarm grid video and it worked, you should check it out
@randyaivaz33563 ай бұрын
EOL's Go to End Of Line, You Should Twist Strands, Larger Wire For Transformer is Better, Then You Can Hook To Ground, Dressing the Wires Can"t Hurt, It Will Work as Shown. Didn't Hear Mention Of Bell Resistor. In Programming, It may Have Ability To Select, EOL Or No EOLS, Eleminating the the Need for Way you Are Doing, Thing I see the Resistors on Board That ir Switches to in Programming.
@kiranvlog78679 ай бұрын
👍👍👍👍
@lnbt110 ай бұрын
How can i add a second keypad?
@poormanmabuza9481 Жыл бұрын
Paradoxdg55+ does not work if I connect it that way
@chulitacruz5385 Жыл бұрын
Como bajar volumen del pitido
@mrmaddocs68752 Жыл бұрын
1 ARMED AWAY May Exit Now 45
@mrmaddocs68752 Жыл бұрын
ZONE 1 MUST BE A FIRE ZONE!
@mrmaddocs68752 Жыл бұрын
Problem 1: Why did you put the EOL resistor in the panel instead of the END OF LINE? (in the panel defeats the purpose of the EOL resistor) Problem 2: The transformer is internally fused, so the AC wires should be connected to the transformer and panel before plugging in the transformer in the 120VAC outlet, You missed the step of plugging in the transformer Problem 3: The battery MUST be connected after the transformer is plugged in!
@mrmaddocs68752 Жыл бұрын
It does not matter what keypad you use Also you do not need to color code the wires so you can check the panel
@lnbt110 ай бұрын
How old are you kiddo? I cannot believe a kid solve my problem! (your short video).
@peligro113 Жыл бұрын
Ahh the ol' beginning of the line resistor😆
@danielreyes59722 жыл бұрын
i wish yall could an xfinity panel
@dmrspec47502 жыл бұрын
Any help and reply would be greatly appreciated - I'm driving myself crazy trying to program one of the function keys (A,B,C,D) on the HW 6160 Keypad to "arm instant" as an easier method than opening the door and pressing # 7. Best Always.
@aliaouel70852 жыл бұрын
Hello i'm new in this field and im using a sensor Honeywell DT-7235T and i want to connect alarm with it, the sensor is working when i plugged but when it try to connect the alarm with it doesn't trigger ! anyone can help ! they are 4 pins 2 for power and 2 for alarm and there is also the tamper ? should i connect the tamper to trigger the alarm ? thanks for help.
@profuse0072 жыл бұрын
There’s gotta be a better system out there with 21st century user interface.
@mauriciopcampos2 жыл бұрын
Hey!! Are you guys still working/active? I'd love to get a contact with you guys, and possible ask for a huuuuuge help! hehehe - i just bought my first house and they left the entire system installed - but not active. Are you guys able to help me get it activated?
@BenEverett13 жыл бұрын
Please take down this completely useless video.
@LUVCHUNK3 жыл бұрын
how not to wire a panel
@pietrotroia1773 жыл бұрын
would this work on a DSC PC5010 control panel? And is it compatible with a mobile app?
@cllistings59143 жыл бұрын
Worthless. Partition 1? Yep. What if I want Nope?
@c-lojefe24223 жыл бұрын
Need a updated video
@ruiftavares4 жыл бұрын
Good afternoon, can I please ask for your help? I have a Ademco Microtech Galaxy 8 C055 alarm, and want to attach a GSM communicator to it. It can work with either NO or NC outputs. I just dont kmow in wich terminals I have to connect the communicator to the alarm, and can´t find any schematics online. Can you help me? Thanks in advance.
@ruiftavares4 жыл бұрын
Good afternoon, can I please ask for your help? I have a Ademco Microtech Galaxy 8 C055 alarm, and want to attach a GSM communicator to it. It can work with either NO or NC outputs. I just dont kmow in wich terminals I have to connect the communicator to the alarm, and can´t find any schematics online. Can you help me? Thanks in advance.
@marjonmotel4 жыл бұрын
Help I do I delete a Zone in my Honeywell alarm pad it shows 09. This 09 showed after my attempt to add a user code. I can bypass 09 but need to remove it.
@netsynctech14204 жыл бұрын
Very helpful video. worked on the ADT Safewatch Pro Custom 3000. tried the manual with no success but this made it really easy to turn off some wireless zones I no longer needed. Also tried to trigger them to see if any fault would come up but nothing, so successful modification. Thank you!
@netsynctech14204 жыл бұрын
programmer code for the ADT 3000 is 6321 then 800
@craigr3064 жыл бұрын
you any good in bed as your wiring skills are shocking.
@mikeclarke30054 жыл бұрын
crap job, no strain relief on wiring, pulled tight, and EOLR not EOL!
@williambuckley61284 жыл бұрын
Does the 6160rf chim have voice capability? If so, how do you enable it?
@iashbanen2 ай бұрын
No it doesnt it has to have a v in the name like (6160v,6150v)
@eclicx35424 жыл бұрын
Wats with all the hate this is a good video I get it’s short but you don’t have to be such a freaking jerk about it like what if you made a cool video and I commented on it and said” YOUR VIDEO SUCKS ITS WORTHLESS THE WORST VIDEO EVER” If u wanna be mean then just don’t say anything about it
@chrisgoebel4 жыл бұрын
Never shows how to add in this video.
@darshan44 жыл бұрын
what the fuck are you doing?
@jiraldpaclibar33284 жыл бұрын
what is the tapping off smoke device..?4 wire or 2 wire?
@grizzlies154 жыл бұрын
Pathetic
@davidfulton98775 жыл бұрын
Why are you teaching them to install the End-Of -Line (EOL) resistor in the panel, This provides NO wiring supervision. Example: If a wire to wire short develops on the field wiring of any zone wired this way, The panel will not respond to an intrusion, making the installer liable for any loss sustained, Insurance companies will destroy you in a courtroom for negligence. This is not wiring according to the manufacturers published instructions. I am very familiar with this control panel, Please learn to install properly before teaching others to do it the wrong way!
@obaidabas11765 жыл бұрын
Hello honeywell I need your help please you help me?
@ThatOneExoRailfan5 жыл бұрын
i have that
@thereelfrost5 жыл бұрын
how can i change the phone number on the same device? thank you for your help
@jaredw835 жыл бұрын
This doesn’t show how to do anything
@mrmaddocs68752 Жыл бұрын
👶🏻👶🏻👶🏻
@dannybarreras61695 жыл бұрын
This is just crazy very very bad! Resistors can not go inside the panel
@mrmaddocs68752 Жыл бұрын
I don't care
@dayarao15555 жыл бұрын
Hai madam...If more thn one sensor please advice wiring configure
@claudiaramos99515 жыл бұрын
*Very good and reliable keyboard>>>**t.co/rNW3BEN8sM** No bugs like the touchscreen device that is available for the Vista 15P. Product shipped and arrived quickly and worked. No hassles.*
@csabacserep49245 жыл бұрын
*Very good and reliable keyboard>>>**t.co/rNW3BEN8sM** No bugs like the touchscreen device that is available for the Vista 15P. Product shipped and arrived quickly and worked. No hassles.*
@davidepierdominici48985 жыл бұрын
*Very good and reliable keyboard>>>**t.co/rNW3BEN8sM** No bugs like the touchscreen device that is available for the Vista 15P. Product shipped and arrived quickly and worked. No hassles.*
@davidepierdominici48985 жыл бұрын
*Excellent!>>>**ur2.pl/1017** Perfectly replaced my ancient Ademco pad from the 90's that the keys stopped working on. Simple install too, just switched off the breaker that powers my alarm system, disconnected the existing pad/unscrewed it from the wall, reconnected the new one/screwed it to the wall, and switched back on the breaker. It took about 2 minutes to synchronize with the main panel and then we we're back up and running. All in all it was a 10-15 minute replacement at the most. I like the alphanumeric display much better than my old fixed display too!*
@jeankasper34645 жыл бұрын
*Excellent!>>>**ur2.pl/1017** Perfectly replaced my ancient Ademco pad from the 90's that the keys stopped working on. Simple install too, just switched off the breaker that powers my alarm system, disconnected the existing pad/unscrewed it from the wall, reconnected the new one/screwed it to the wall, and switched back on the breaker. It took about 2 minutes to synchronize with the main panel and then we we're back up and running. All in all it was a 10-15 minute replacement at the most. I like the alphanumeric display much better than my old fixed display too!*
@dijanajankovic776 жыл бұрын
How to add a name to code number?
@boywithuke2.o9836 жыл бұрын
I’m renting a home and my son pushed a bunch of different buttons on the key pad and set the alarm off, which wouldn’t disarm so every time I we opened any door the alarm went off. In a panic I cut the wires in both keypad, but the alarm was still going off. I found the motherboard where all these wires are and unscrewed all of them and that worked. My question is who I do call to fix the keypad that I cut and does anyone know how much that would cost? Thank you in advance.
@mikeclarke30054 жыл бұрын
Hire someone that knows what the heck they are doing
@tonyjavorsky94246 жыл бұрын
worthless video
@guesswhomartin92496 жыл бұрын
Not looking at the wiring schematics, but looks like your alarm panel is incorrectly wired. Your resister should go on the zone ( really needs to be in the field, but inside the panel is ok too ) but keep the resister on the zone terminal and the return wire on the common terminal. On this panel AC wire doesn't have positive and negative. It's AC, It's Alternating Current. Only terminals 3,4,5 matter for power. 3,4,5 are DC. And why is he using this screw driver ? Use a real screw driver.