@josiasborges4069
@josiasborges4069 25 күн бұрын
There is any list for multi products ( with the same type) in the same cell?
@IGEXAOUK
@IGEXAOUK 24 күн бұрын
In the advanced/scale level package there is a graphical list and database section called Compressed BOM, which produces a quantified bill of materials together with a column for the tags e.g. K1-9, K12, K15. I think this is what you're asking for.
@josiasborges4069
@josiasborges4069 24 күн бұрын
@@IGEXAOUK yah, but I`m just saw this option on VIEW not on graphical list. I think is some EXPORT xxxx command is hide after solve this I will need know which the parameters can I use on this Graphical list.
@josiasborges4069
@josiasborges4069 24 күн бұрын
Well, I went to the project menu in Graphical list and then in Definition list and look for parameter export_4207 creating a new definition, as I don't know which codes to use I used the "component list" template in See electrical default installation, and then it gave an acceptable result now I need to see how to make each component show its page in the line of this graphical list.
@e-design94
@e-design94 25 күн бұрын
How to change signal direction in V8R2?
@IGEXAOUK
@IGEXAOUK 25 күн бұрын
Either manually switch symbols or tap function key F6, hold Ctrl and select the graphical elements, then select mirror and click 2 points for an axis to mirror the graphics. The same could be done with rotation if its just the graphics. Otherwise, upgrade to V8R4 :)
@e-design94
@e-design94 21 күн бұрын
@@IGEXAOUK can you make a video tutorial?
@florincheche163
@florincheche163 Ай бұрын
What software are you using?
@IGEXAOUK
@IGEXAOUK Ай бұрын
SEE 3D Panel, this is designed developed and supported by etap, part of the Schneider Electric group.
@MarcosMalave-hb8vr
@MarcosMalave-hb8vr 3 ай бұрын
hi, i have a problem using the option: "commands - colors- brep- change color on all faces" does export the correct color to the 3dpdf, however when looking for greater detail using the "commands - colors- brep- change color on single face" does not export the color assigned to the 3dpdf
@IGEXAOUK
@IGEXAOUK 3 ай бұрын
Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.
@Marcosdj18
@Marcosdj18 3 ай бұрын
Hello, I have a question, because the symbols when exported from see electrical to 3DPDF lose or do not take the assigned color from the commands - color - brep option? When exporting them, they appear without color in the pdf file
@IGEXAOUK
@IGEXAOUK 3 ай бұрын
Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.
@Marcosdj18
@Marcosdj18 3 ай бұрын
@@IGEXAOUK thanks for your answer
@Marcosdj18
@Marcosdj18 3 ай бұрын
Hello, I have a question, because the symbols when exported from see electrical to 3DPDF lose or do not take the assigned color from the commands - color - brep option? When exporting them, they appear without color in the pdf file
@IGEXAOUK
@IGEXAOUK 3 ай бұрын
Hi Marcos can you tell me which version of 3D Panel and which PDF viewer you're using and I'll check this out and get back to you.
@Marcosdj18
@Marcosdj18 3 ай бұрын
@@IGEXAOUK thanks for your answer, 3D panel designer version is V3R1 SP2 (3.12.21.5), I’m using acrobat reader DC, But the problem is not the pdf viewer.
@IGEXAOUK
@IGEXAOUK 3 ай бұрын
@@Marcosdj18 Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.
@Marcosdj18
@Marcosdj18 3 ай бұрын
@@IGEXAOUK thanks for your answer
@Marcosdj18
@Marcosdj18 3 ай бұрын
@@IGEXAOUK thanks for your answer
@Marcosdj18
@Marcosdj18 3 ай бұрын
Hello, I have a question, because the symbols when exported from see electrical to 3DPDF lose or do not take the assigned color from the commands - color - brep option? When exporting them, they appear without color in the pdf file
@IGEXAOUK
@IGEXAOUK 3 ай бұрын
Yes you're right, currently these colors applied using this command are not displayed in the exported PDF, only the blocks original color is used. I've added this to the requested enhancements list.
@Marcosdj18
@Marcosdj18 3 ай бұрын
@@IGEXAOUK thanks for your answer
@Leo-wc3bc
@Leo-wc3bc 4 ай бұрын
Hello, Will there be V8R4 tutorial ? I really enjoy watching your videos and im trying to learn SEE ELECTRICAL. Best regards
@IGEXAOUK
@IGEXAOUK 4 ай бұрын
Thanks for the feedback, glad you're enjoying the videos. There aren't any plans to release additional full tutorial videos for now. The base functionality available in V8R1 still applies to V8R4, we've just added new features which are covered in the additional video snippets. If there's anything in particular you think isn't well documented, please tell us and we'll look at creating something to help.
@Leo-wc3bc
@Leo-wc3bc 4 ай бұрын
​@@IGEXAOUK Hello, I recently bought SEE electrical grow with web catalogue and i have a problem. After downloading symbols from the catalouge, they are nowhere to be found. Is there a quick fix or should I contact the customer help team. Best regards
@IGEXAOUK
@IGEXAOUK 4 ай бұрын
@@Leo-wc3bc After downloading new parts you should be able to find these in the Components panel. The equipment should link to the appropriate symbol. To see the symbols you may need to right-click in space in the symbols panel and select the properties and enable the view of the @Manufacturer symbol database. These are the ones downloaded via the web catalogue.
@serggomon
@serggomon 5 ай бұрын
Hello, I would like to ask you how is possible to make reference and comments/description for the PLC signal in one line, like 'Merge' in Components? For example: 'ChannelDescription =FF01\+S1\ 25.6 ' on the corresponding PLC main view?
@IGEXAOUK
@IGEXAOUK 5 ай бұрын
Its a good idea so I'll submit this to the development team as an enhancement. At the moment its not possible to merge attributes together on a symbol.
@lrnmt2000
@lrnmt2000 5 ай бұрын
Hi sir. Do you know how and where to download symbols library?
@IGEXAOUK
@IGEXAOUK 5 ай бұрын
Hi @Irnmt2000 most equipment downloaded from the web catalog provide both circuit diagram and 3D Panel symbols. The web catalog is available through subscription from your local sales team. We do also have some additional 2D and manufacturer specific symbol databases for the circuit diagrams which we can send out on request. contact [email protected] for more information.
@Kabukihkaka
@Kabukihkaka 5 ай бұрын
Hi, I am using V8R3, spanish language versio, I cant find this command. Can you please write the exact command to use in the "enter command" text window? thank you
@IGEXAOUK
@IGEXAOUK 5 ай бұрын
BlockConfigurator is the command for a blocked group on a page and DrawingConfigurator for the whole page configuration.
@ahmedaldrajee7705
@ahmedaldrajee7705 7 ай бұрын
Hello dear, when I access the program’s web catalog, it asks for a proxy number, where can I get it? Thank you
@IGEXAOUK
@IGEXAOUK 7 ай бұрын
This usually indicates that communication with the web server is not possible. Please check that you don't have a firewall blocking access to the web catalog. The address is in the settings of the equipment manager.
@josiasborges4069
@josiasborges4069 7 ай бұрын
Can I show All terminals connected in on component for example my plc card L+ is connected on X1:2, X1:3, X1:4 AND X1:5 for example.
@IGEXAOUK
@IGEXAOUK 7 ай бұрын
Most things are possible with a database containing the project information :) Just need to clarify if you need all terminals connected on a specific potential or all terminals connected to a specific symbol.
@josiasborges4069
@josiasborges4069 7 ай бұрын
@@IGEXAOUKis on symbol, but I was thinking there was a especifiic option on assembly for do that, I wanted assembly do all the connections beteween components\symbols and terminals.
@uppalurisravanthi7277
@uppalurisravanthi7277 8 ай бұрын
Please give me a suggestions about it
@uppalurisravanthi7277
@uppalurisravanthi7277 8 ай бұрын
I tried to create new symbol but connections dots not displayed?
@IGEXAOUK
@IGEXAOUK 8 ай бұрын
Hi @uppalurisravanthi7277, make sure if you're adding the connection points as text to use the correct attribute for Connection - Connection, or change the attribute to this afterwards. The dots should then appear if you have the view setting switched on for connection points. Alternatively, place another symbol, right-click and exploded it and copy the connection text from there.
@uppalurisravanthi7277
@uppalurisravanthi7277 8 ай бұрын
Recently installed free 30 days software
@webprotector19
@webprotector19 8 ай бұрын
hello @IGEXAOUK, i have a question for you. When i generate Legend, some symbols won`t show on legend (ex. "Two way switch" & "intermediate switch"). Do you know what can be the problem?
@IGEXAOUK
@IGEXAOUK 8 ай бұрын
Hi @webprotector19 this could be one of 2 issues 1) The symbol has been created and copied around rather than placed from a symbol folder, so no symbol name will be associated with it in the bottom-right when double-clicking 2) The symbol has not been added to the list in the command GenerateLegendMapping section.
@webprotector19
@webprotector19 8 ай бұрын
@@IGEXAOUK Thank you for the response. I was the second answer: 2) The symbol has not been added to the list in the command GenerateLegendMapping section. You are the best!
@josiasborges4069
@josiasborges4069 8 ай бұрын
you removed the "name" from atributes?
@IGEXAOUK
@IGEXAOUK 8 ай бұрын
Hi @josiasborges4069 please can you clarify your question, I'm not sure what this refers to.
@Automatyk2Hydrotech
@Automatyk2Hydrotech 8 ай бұрын
Its does not work.... I cant change the direction...
@Automatyk2Hydrotech
@Automatyk2Hydrotech 8 ай бұрын
Sorry, it's working. It was problem with my System Symbols
@IGEXAOUK
@IGEXAOUK 8 ай бұрын
@@Automatyk2Hydrotech Thanks for the quick update. Yes if you copy the V8R3 system.ses file across to V8R4 then you'll miss out on the direction swapping for the signal references.
@josiasborges4069
@josiasborges4069 9 ай бұрын
I have a doubt, but it's not about the video. I have been using this software for a long time and have a lot of development and experience in the autogen module, but now since the terminals have become like components, when I generate the auto diagram they no longer increase the numbering according to the order of the terminal strip, it simply repeats the saved number. Is there any easy way to fix this (some config) or will I have to change all my drawings to # in the terminal numbers?
@IGEXAOUK
@IGEXAOUK 9 ай бұрын
Can you tell us what version and build of SEE Electrical you're using. It might be something that the development team needs to look into.
@josiasborges4069
@josiasborges4069 9 ай бұрын
@@IGEXAOUK 8r2 sp10
@josiasborges4069
@josiasborges4069 8 ай бұрын
@@IGEXAOUK Was a bug, now is already fixed
@josiasborges4069
@josiasborges4069 10 ай бұрын
In this version I can create a cross-referenced component where the first part is a component and the second part is a component not in list (except as target). In my example I don`t want combine all parts of my components for avoid duplicates on material list, so for the first part of my symbol is component and the anothers not, But I don`t got sucesfull unsing cross referencies.
@IGEXAOUK
@IGEXAOUK 10 ай бұрын
In newer versions of SEE Electrical, use the 'Contacts, not specified' symbol type for the auxiliary symbols and add cross reference attributes to these and the 'Component with Aux Contacts' symbol to show the page references. Each product used will have just one set of equipment for the material list.
@josiasborges4069
@josiasborges4069 11 ай бұрын
I want change the kind of text showed on 180010 in my example I want replace the text "Electric Diagram IEC" for "x" do you have any Idea ?
@IGEXAOUK
@IGEXAOUK 11 ай бұрын
If you have the advanced or scale level package then you can use the report generator to add a new calculated field to the field list such as; iif([180010]= 'Circuit Diagram IEC','x',[180010]) The conditional iif statement is not available directly in the Graphical Lists.
@josiasborges4069
@josiasborges4069 10 ай бұрын
@@IGEXAOUK Can you make a video explain How to, I have de Advanced mode?
@IGEXAOUK
@IGEXAOUK 10 ай бұрын
Check this video for adding a calculated field kzbin.info/www/bejne/qautpX-hmb-HlbM
@josiasborges4069
@josiasborges4069 10 ай бұрын
@@IGEXAOUK Thanks for helping this will be a lot useful
@plavooki95
@plavooki95 11 ай бұрын
Hello, In the BOM list, is it possible to aggregate cable lengths only by cable type or by some other attribute? E.g. description 00? I have the problem that I have the same cable types, but they don't all have the same text in the attribute "description 00"... Is it possible for the program to sum the cables by two different attributes?
@IGEXAOUK
@IGEXAOUK 11 ай бұрын
The BOM is not very flexible, it will quantify lengths or number of equipment only. The report generator is much better if you have the Advanced level, and if you base the report on the Parts list (itemized) and then add your own group headers /footers to sum or count the number of occurrences.
@plavooki95
@plavooki95 11 ай бұрын
Hello, thanks for the useful tips. Is there some control code that sums the lengths of cables of the same type? In the parts list or in the cable list, I want to add up e.g. length of all cables type Ölflex Classic 110 and conductor cross-section 3x1,5 mm2.
@IGEXAOUK
@IGEXAOUK 11 ай бұрын
Yes, in the BOM list (Export_3102) the field #180040 sums the total lengths of cables (or cable trays and DIN rails placed in the 2D cabinet) for each type, or the number of components of a non-cable type. The field #180041 only totals the lengths and outputs 0 for non-cable types and the field #180042 just counts the number of components or cables (ignoring the lengths) of each type.
@plavooki95
@plavooki95 11 ай бұрын
@@IGEXAOUK Thank you, this was very helpful!
@plavooki95
@plavooki95 11 ай бұрын
Hello, my desire is that i want to show in the cable list the cable that has multiple lines of text in the wiring diagram. Is it possible to show this in one extended line in the cable list? Is it possible to make a command for multiline text? I tried the following command but it didn't work: #160030 &MultiLine [ ]
@IGEXAOUK
@IGEXAOUK 11 ай бұрын
Try the following: #160030 $SingleLine [ ]
@victorflyvbjerg
@victorflyvbjerg Жыл бұрын
Hi, is it possible to extract values from "View, BOM" and edit those values in report generator. Say that I want to extract AMP values for instance "C 16A 30mA", but I don't want the C (from C curve characteristic) and I don't want the "A 30mA" either, just the raw number. I know it is possible to do in excel, but it would be nice if it was possible in report generator directly. Also, is it possible to add different sources for the Report Designer, because I need values from "Editor, Components" as well, in my report. As I see it, I have to choose one source and I can't combine several sources.
@IGEXAOUK
@IGEXAOUK Жыл бұрын
In the 'Fields' list you can add new expressions which provide similar functions to excel to extract, replace, concatenate and trim text fields for the report. For the requirement of multiple data sources you can add a custom query to the report generator when designing so combine data sources (queries) where there is a link between the sources. Its using basic SQL. Please contact [email protected] for more details if needed.
@santoshsengunther6974
@santoshsengunther6974 Жыл бұрын
Hi, Could you please help me... Do you know how to measure the overall heat dissipation of the electronic components? Here the component is ADAS front camera situated on car behind the windshield? Having processor, image sensor or other electronic components
@IGEXAOUK
@IGEXAOUK Жыл бұрын
I'm sorry but our heat dissipation calculation is specifically tailored for electrical components contained within a panel, where the panel is either placed against a wall or next to another panel, which won't help with electronic components in a car.
@samuelkctweneboah-kodua5660
@samuelkctweneboah-kodua5660 Жыл бұрын
The best way to find a lot of people becoming used to this best light weight software is to introduce students version . the more we practice and familiar we recommend to industries to use as soon as we are employed . As software developer myself i understand what goes into it so making it free for students is difficult but i think numbers with time.
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Thats a great point @samuelkctweneboah-kodua5660. We do have student licenses available so if you get in contact directly or via your local sales team we can work with your educational establishment to provide this.
@samuelkctweneboah-kodua5660
@samuelkctweneboah-kodua5660 Жыл бұрын
GREAT
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Thanks for the feedback :)
@KYSFaggo
@KYSFaggo Жыл бұрын
What do I do when I try to create a new project, but don't see any templates after typing in my project name ?
@IGEXAOUK
@IGEXAOUK Жыл бұрын
If this is for V8R4 make sure to download and install an environment (IEC - European/NFPA - North America) so there are workspace templates with .sep extension in the templates folder. This is the default location for the templates: C:\Users\Public\Documents\IGE+XAO\SEE Electrical\V8R4\Templates
@KYSFaggo
@KYSFaggo Жыл бұрын
@@IGEXAOUK Thank you for the reply. I figured it out with a little help from a mate in class 🙂It is now downloaded and installed. Now I can create a project and I can't wait to try out your software in class ! Cheers !
@ទីស្រអែម-ទ8ត
@ទីស្រអែម-ទ8ត Жыл бұрын
Hi , When I open the see electrical selector I just see (system & template)
@IGEXAOUK
@IGEXAOUK Жыл бұрын
If this is See Electrical V8R4 then make sure to install a suitable IEC or NFPA environment. You can find the downloads here: ige-xao-uk.com/downloads/
@Xenomorphin1
@Xenomorphin1 Жыл бұрын
Does the software have a perpetual fallback license, or is it subscription only? I'd be willing to buy it, but we don't do electrical panels too often, since we're mostly a medical company.
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Could you please tell me your country of residence? Then we will get the right contact person for you to answer your question. Thank you!
@Xenomorphin1
@Xenomorphin1 Жыл бұрын
@@IGEXAOUK It's Poland. I had someone call this morning, I'll call them back and ask.
@qzorn4440
@qzorn4440 Жыл бұрын
I am looking for an electrical CAD that has features like SolidWorks with a hobby price. This hobby project requires linking the PLC schematic with 3D sensors, 3D wringing harness. The Cad video looks very interesting. What is the software cost? Thanks.
@IGEXAOUK
@IGEXAOUK Жыл бұрын
You can see our subscription bundles and prices here: www.ige-xao.com/en/us/see-electrical/ They can nevertheless vary from country to country so please contact us via our website for more information: www.ige-xao.com/en/formulaire/?need=product&product_wanted=SEE%20Electrical
@medaminekalboussi930
@medaminekalboussi930 Жыл бұрын
thank u so much really helpful i hope u still making educational vids about see electrical right now
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Hi @medaminekalboussi930, yes we're still creating videos. Hope you continue to find them useful :)
@emran.hexecutive6317
@emran.hexecutive6317 Жыл бұрын
sir....pls give me ,,,,see electrical v8r2 software i can get it from any link urgent helpe me pls....
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Check out the previous versions section on ige-xao-uk.com
@DiwakarShankar-rz7jx
@DiwakarShankar-rz7jx Жыл бұрын
in see electrical, stretch command is not available? and also, what is the shortcut key for copy with reference point. i request to make a series of videos regarding commands only.
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Graphical stretch can be enabled using the trackers (Alt+T), and stretch of connected wires using the Electrical - Wire Rubberband command. Right-click to select Copy with Base Point or add a new keyboard shortcut by right-clicking on the menu, accessing the quick access tool bar settings and clicking through to the keyboard shortcuts. I hope this helps.
@oseiasalencarjunior5145
@oseiasalencarjunior5145 Жыл бұрын
Great Job!
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Thanks for the feedback Oseias.
@R1zla212
@R1zla212 Жыл бұрын
HOW TO SET A BASE POINT FOR PICK AND PLACE
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Method 1 - drag the component from the point that should be the insertion/reference point. Method 2 - right-click the symbol folder and select Save and enter X and Y or select a point on the page before entering the symbol name. Note that method 2 was added in V8R3 so earlier versions don't have this option.
@R1zla212
@R1zla212 Жыл бұрын
@@IGEXAOUK THANKS! IT HELPED
@MrBenLacoste
@MrBenLacoste Ай бұрын
In Symbols pane, find System, expand, find Symbol Orign and expand. You will find a red sight cross that you can move to a connectiono point of your symbol per say and then make your symbol as a block and drag it to the Symbols pane. When you will pick it back from the Symbol pane, your pick point will be where you had put the sight cross. Voilà!
@dineshbabu6596
@dineshbabu6596 Жыл бұрын
Software link &product key plz
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Hi Dinesh, you can download the software as a free 30 day trial from our Web site, either www.ige-xao.com or ige-xao-uk.com
@dineshbabu6596
@dineshbabu6596 Жыл бұрын
See electrical license installation video &license key
@dineshbabu6596
@dineshbabu6596 Жыл бұрын
India sales team phone number
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Please contact Mohnish and his team #1/1, Gover Road Cox town Bangalore-560005 Phone : +91 9535235447
@patrikhercut6197
@patrikhercut6197 Жыл бұрын
Hello, I would like to ask you how is possible to create a single-line cable from multiple wires. Let's say 3 wires from the terminal creates a 3 cores cable. I saw the function multicore but I am not sure how is possible to work with this. Can you give me some ideas? Thank you!
@IGEXAOUK
@IGEXAOUK Жыл бұрын
OK so there is an advanced level function called Multicore which allows a single wire to be marked as having multiple cores. This can then be edited using the Multicore properties and each separate core defined by its connection at each end, color and size. This doesn't however allow a fan out of wires at either end. This isn't possible unless custom cable symbols are designed, with a gap between the 2 connection points, which is filled in with your preferred cable fan graphics.
@Schmorrison
@Schmorrison Жыл бұрын
Is V8R4 only available for the NFPA version? I use IEC normally but only see upto V8R3 SP6
@IGEXAOUK
@IGEXAOUK Жыл бұрын
There is only 1 installation file now for the V8R4 program. You can then install the environment/s you want separately. IEC and NFPA can be installed from here ige-xao-uk.com/Downloads
@edimarneves0455
@edimarneves0455 Жыл бұрын
Olá tem versão em português Brasil ou Portugal?
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Sim, verifique a seção 'Comunidade' para obter uma lista de idiomas suportados.
@gerardbrouwer2581
@gerardbrouwer2581 Жыл бұрын
so i have some small problems. @4:44 i can't change the PLC adress numbering method, it doesn't allow me to make the change. and i think that is why @8:30 the numbering doesn't work automaticly work and @8:53 i cant select the PLC adress.
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Auto numbering for the PLC is limited to the standard and advanced level packages, could it be that you're working with the basic level? A neat workaround is to open a spreadsheet to quickly generate a sequence of addresses, copy (Ctrl+C), then paste (Ctrl+V) the 4/8/16/32 addresses while the first address is selected in the Component Properties dialog for the PLC Main.
@Schmorrison
@Schmorrison Жыл бұрын
Been using the program for about a year, this is definitely a feature I've been hoping for. Keep up the videos!!
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Thanks for the feedback. Don't forget, most new features come from user requests so keep pushing the product.
@soufelec6216
@soufelec6216 Жыл бұрын
Hello, I am a student. How can I get an app for free?
@IGEXAOUK
@IGEXAOUK Жыл бұрын
You can download the software and environments from ige-xao-uk.com and use as a trial version for 30 days. This is advanced level but with a 3 circuit diagram page per project limit. I'm aware of many Colleges and Universities providing 'Educational' versions of the software, so its worth contacting them and asking, or getting in touch with the IGE+XAO sales team within your region.
@erseayd
@erseayd Жыл бұрын
sir, when I enter the symbols section on my 3d panel drawing screen, no objects and materials are visible. It is empty, what is the reason please explain
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Please make sure to install the example 3D Panel environment: ige-xao-delivery.j-doc.com/s/nWiC7QfigXy89bq/download Then check in the settings that the symbol path points to the public documents folder where the symbols have now been added.
@erseayd
@erseayd Жыл бұрын
@@IGEXAOUK First of all, thank you for your interest. But I still couldn't solve the problem. All of the relevant folders seem to exist, but the 3d symbols are still not visible in the program. @ABB.3DModels, @Allen-Bradley.3DModels ... etc these files appear as blank screen in the program, I cannot select them.
@IGEXAOUK
@IGEXAOUK Жыл бұрын
@@erseayd OK couple of things to check. The environment link I sent was for 3D Panel V2R2 symbols. Get back to me if you have the older V2R1 since there are new features that mean the symbols won't be visible in the older version. Next, check in the symbols folder that each 3D catalogue has both a folder @Manufacturer.3DModels (containing the model files) and an index file called @Manufacturer.ses3d. If there's still no joy, ping us on [email protected], thanks.
@apvivek5368
@apvivek5368 Жыл бұрын
Can we design MV panels like with 15to20 ACB outgoing feeders? And have one more quiz,! Can we use this 3d model to for machining like laster sheetmetal laser cuttings?
@IGEXAOUK
@IGEXAOUK Жыл бұрын
Yes, any electrical panels can be designed using the 3D Panel+ package. There's functionality to insert copper with bends and hole drilling templates as well as the option to output dxf/dwg or specific Perforex or Steinhauer drill/cutout templates for any mounting surface.