Faulty Programmer
1:51
3 жыл бұрын
Earth Fault Loop Impedence
6:50
4 жыл бұрын
Mid-Position Valve - How it works
7:40
W Plan - Priority Hot Water
10:15
4 жыл бұрын
Y-plan - mid-position diverter valve
11:41
Veissmann Vitodens on the bench
7:40
Пікірлер
@ScottRosa2008
@ScottRosa2008 5 ай бұрын
Thanks for this video. I have had problems with my heating working intermittently for the last few months. It will work fine for a few days or maybe a week and then the boiler won’t fire when the call for heat is made. If I turn it all off for a couple of days and then start again it will work again for a while. I assumed it was the boiler at fault nd maybe the PCB but then I noticed the hot water on its own works fine, boiler fires no problem and it works as it should. It only seems to be when CH only is selected. I can hear the boiler clicking on and off trying to start so I think it communicates with the room stat, goes to start and then the mid position actuator doesn’t move as it should. Does this sound the likely issue to you because if it was the brass valve then the hot water wouldn’t work either? Thanks.
@mj24881
@mj24881 9 ай бұрын
love what you do. need to know you, I need your help please. where are you based roughly?
@ranat5526
@ranat5526 10 ай бұрын
Brilliant, had me going round the bend with a Biasi advance 30c combi. Sometimes the CH would work but as I was using a netatamo over the Internet I saw my gas bill plunge to next to nothing with the tenants complaining that the heating was off. I was adamant the heating was on because netatmo told me it was on my smartphone!!
@pauljarrett2849
@pauljarrett2849 11 ай бұрын
Many thanks for another great video, so thoroughly explained! I was worried why my motorised valve was hot at 6:15 when everything was off, and now I know why (but not really happy about it). Still not fathomed out why my boiler shuts down for 10 mins when the valve changes over from HW to heat🤔
@pauljarrett2849
@pauljarrett2849 11 ай бұрын
Great explanation, thank you! Helped me find the fault.
@asimf4505
@asimf4505 11 ай бұрын
Massively underrated video. It's probably one of the best explanations on YT. Really well done.
@dantronics1682
@dantronics1682 Жыл бұрын
Thanks for that, I thought it was a stepper motor in there. now I know
@johnbrooke9692
@johnbrooke9692 Жыл бұрын
thanks for your help i tested my motor its OK . but when its in it will not switch bact to hot water no power too the motor
@abdulsatter8674
@abdulsatter8674 Жыл бұрын
This is not dhwp
@malwesterdale9481
@malwesterdale9481 2 жыл бұрын
Great video thanks - does the synchron motor normally get hot holding the valve shut?
@adamcarter781
@adamcarter781 2 жыл бұрын
Yes and leads to premature wear in my opinion.
@chohanchohan8208
@chohanchohan8208 2 жыл бұрын
This is by far one of the best videos that addresses the white elephant in the room…everyone knows about it but don’t actually know what it is for and how it works 🍺🍺🍺
@puttingtechniques
@puttingtechniques 2 жыл бұрын
Great vid mate. Thanks
@jonathanswann5852
@jonathanswann5852 2 жыл бұрын
Hi Adam. Great video. I set up my system similar to yours but I used choc box instead of wago wiring centre. If, as you suggested, having 2 zones for heating and one zone for hot water (3 switches in programmer), I presume you would need to use a 3 channel programmer as opposed to 2 channel in your video
@timothymay9045
@timothymay9045 2 жыл бұрын
Do you recommend the socket and see
@adamcarter781
@adamcarter781 2 жыл бұрын
It works fine, is reliable and not too expensive.
@timothymay9045
@timothymay9045 2 жыл бұрын
Thanks
@beggersu
@beggersu 2 жыл бұрын
Great tutorial Adam, thanks
@beggersu
@beggersu 2 жыл бұрын
Great video Adam. Many thanks
@jezlucas3878
@jezlucas3878 2 жыл бұрын
Best explanation I've seen thanks
@iraqi1960
@iraqi1960 2 жыл бұрын
Are these low voltage motors? and how many Volts in the supply leads?
@camsy83
@camsy83 2 жыл бұрын
They are 230Vac
@stevekelly5166
@stevekelly5166 11 ай бұрын
At 0m57s you have your answer. 220-240V ac
@reganobrien8262
@reganobrien8262 3 жыл бұрын
Hi, i was getting no movement or resistance on the spring when all power is off the switch to go from auto and manual is lose, when turn on heating or hot water nothing is moving and boiler not firing up but pump is running. I’m a gas safe plumber just looking for some advice. Thanks
@adamcarter781
@adamcarter781 3 жыл бұрын
Body spindle may be stuck, remove head, check spindle. look inside head to see if spring is broken. Boiler should fire on HW without 3PV operation, you may need to investigate this separately. Good luck.
@DrBobee76
@DrBobee76 3 жыл бұрын
Nice mechanical conzruction. I think the Electronic board of boiler add the signal and it periodically round, when the boiler heats the radiators, and you open a hot water tap. But I want ask some question. What is the heating and what the hot water storage tank heating, the pin out or in? What is the base state for example diverter valve(Ariston), from above, I ask because my old Ariston quadriga heats the radiators too when only hot water is used, and vice versa. It strarted when I turned on the thermostat after 4 months of summer heating break.
@winstonb4828
@winstonb4828 3 жыл бұрын
You definitely need to make more videos your explanation is spot on mate
@aidensholeh3696
@aidensholeh3696 3 жыл бұрын
Best video on the subject so far. And about half as long as the rest. 👍🏼
@rayc1503
@rayc1503 3 жыл бұрын
Brilliant 👍🏼
@bahiaharjinder
@bahiaharjinder 3 жыл бұрын
Hi adam your videos are extremely useful please keep them comming thankyou 👍
@macpatel7810
@macpatel7810 3 жыл бұрын
Really enjoyed that video. Excellent .. great explanation. Just subscribed.. Cheers. Mac
@Dog-whisperer7494
@Dog-whisperer7494 3 жыл бұрын
You should test at the fused spur then then junction box You don’t know if the earth conductor has come out at the fused spur if so you’re test results would be invalid
@waynenixon729
@waynenixon729 3 жыл бұрын
I've seen systems where the earth has been used as a switching wire. Just remember the earth wire protects the cable and would cause the circuit breaker to trip if someone cut through the cable.
@waynenixon729
@waynenixon729 3 жыл бұрын
Nicely explained but i can see one problem, all cables need a earth wire, as the earth wire protects the cable if someone was to cut through the cable or if there was a problem with in the cable.
@richardbinder5175
@richardbinder5175 3 жыл бұрын
Adam Carter..... wow how you doing mate, all good by the look of it, take care hope all is well
@adamcarter781
@adamcarter781 3 жыл бұрын
I'm good thanks. Hope all is well with you and yours.
@MSKChess
@MSKChess 3 жыл бұрын
Please make more vids if you have the time :)
@MSKChess
@MSKChess 3 жыл бұрын
Its really great to have all the components semi isolated and view the sequence of events.
@MSKChess
@MSKChess 3 жыл бұрын
yes first class video, would be awesome if we could get a measurement of the partially rectified DC current going back to the PCB from the electrode.
@MSKChess
@MSKChess 3 жыл бұрын
These videos for Gas Engineers who are just gaining experience are awesome, thanks so much Mr. Carter.
@MSKChess
@MSKChess 3 жыл бұрын
2 awesome !
@MSKChess
@MSKChess 3 жыл бұрын
Fantastic. Best tutorial on you tube.
@MSKChess
@MSKChess 3 жыл бұрын
amazing! I got stuck today trying to determine which wire did what on a three port valve. Thank you so much for the comprehensive and clear explanation.
@ndelockedout
@ndelockedout 3 жыл бұрын
Just wondering who makes that wiring centre??
@jonathanswann5852
@jonathanswann5852 2 жыл бұрын
That's a wago L32 wiring centre
@tomaszbodz1913
@tomaszbodz1913 3 жыл бұрын
Hi thanks for the wideo, When valve 3 port is set to central heating it is all the time a hot motor and there is a soft noise coming from it, It is suppose to be like this ? How do I change to heating water everything is ok
@carsonelias7432
@carsonelias7432 3 жыл бұрын
instaBlaster
@markrussell9719
@markrussell9719 3 жыл бұрын
How can I achieve Hot Water priority on an S plan plus system please?
@adamcarter781
@adamcarter781 3 жыл бұрын
Instal a relay switch between room stat and zone valve. Relay powered by room stat, hot water off to common, normally open to feed zone valve. Programmer set to gravity so that hot water on is tied to heating on. Hope that makes sense. Good luck.
@markrussell9719
@markrussell9719 3 жыл бұрын
@@adamcarter781 Thank you - Much appreciated.
@jgalt3716
@jgalt3716 4 жыл бұрын
Great Video, very well done. My HE24 packed up and will only try to fire up if left for a good while. It fired up before but when I called for hot water it crashed and gave an L9 code. User manual (I think) is saying thermistor or heat exchanger blockage. Am I missing something?
@adamcarter781
@adamcarter781 4 жыл бұрын
Hi, thanks for watching. Only gas safe registered engineers should work on gas appliances.
@jgalt3716
@jgalt3716 4 жыл бұрын
@@adamcarter781 I was not working on it, I was trying to diagnose it
@mansourtabaie2573
@mansourtabaie2573 4 жыл бұрын
Excellent video. Thanks for your effort to educate people.
@mansourtabaie2573
@mansourtabaie2573 4 жыл бұрын
Another wonderful educational video by you Adam. Your videos and your demonstration skill is far better than most existing related videos. Well done.
@callumedward405
@callumedward405 3 жыл бұрын
sorry to be offtopic but does anyone know of a way to log back into an Instagram account..? I was stupid lost the password. I appreciate any assistance you can offer me.
@korbynxander6
@korbynxander6 3 жыл бұрын
@Callum Edward Instablaster :)
@callumedward405
@callumedward405 3 жыл бұрын
@Korbyn Xander Thanks for your reply. I got to the site thru google and im waiting for the hacking stuff atm. Looks like it's gonna take quite some time so I will reply here later when my account password hopefully is recovered.
@mansourtabaie2573
@mansourtabaie2573 4 жыл бұрын
Great- Simple but an example of an effective and educational video. Well-done
@scottiedog4236
@scottiedog4236 4 жыл бұрын
Nice one ☝️
@livingsoul.4105
@livingsoul.4105 4 жыл бұрын
Thanks for that video just fixed mine
@astront917
@astront917 4 жыл бұрын
great video, our ideal esprit he 35 just packed up today ! fires up for hot water immediateley when taps/shower operated but will not fire for central heating, have hive thermostat calling for heat but boiler display still shows a 0, am thinking pcb has died ?????
@adamcarter781
@adamcarter781 4 жыл бұрын
Hot water working suggests pcb ok. Most likely issue is lack of hard signal from Hive to boiler...
@astront917
@astront917 4 жыл бұрын
@@adamcarter781 thanks for your reply, checked that,seems to be ok,drops out when hive off then cuts in when call for heat activated from hive, strange as boiler fires up for hot water. thanks again