Mid-Position Valve - How it works

  Рет қаралды 15,906

Adam Carter

Adam Carter

Күн бұрын

Пікірлер: 12
@pauljarrett2849
@pauljarrett2849 Жыл бұрын
Great explanation, thank you! Helped me find the fault.
@jezlucas3878
@jezlucas3878 3 жыл бұрын
Best explanation I've seen thanks
@beggersu
@beggersu 3 жыл бұрын
Great tutorial Adam, thanks
@ScottRosa2008
@ScottRosa2008 7 ай бұрын
Thanks for this video. I have had problems with my heating working intermittently for the last few months. It will work fine for a few days or maybe a week and then the boiler won’t fire when the call for heat is made. If I turn it all off for a couple of days and then start again it will work again for a while. I assumed it was the boiler at fault nd maybe the PCB but then I noticed the hot water on its own works fine, boiler fires no problem and it works as it should. It only seems to be when CH only is selected. I can hear the boiler clicking on and off trying to start so I think it communicates with the room stat, goes to start and then the mid position actuator doesn’t move as it should. Does this sound the likely issue to you because if it was the brass valve then the hot water wouldn’t work either? Thanks.
@puttingtechniques
@puttingtechniques 2 жыл бұрын
Great vid mate. Thanks
@MSKChess
@MSKChess 4 жыл бұрын
2 awesome !
@malwesterdale9481
@malwesterdale9481 2 жыл бұрын
Great video thanks - does the synchron motor normally get hot holding the valve shut?
@adamcarter781
@adamcarter781 2 жыл бұрын
Yes and leads to premature wear in my opinion.
@tomaszbodz1913
@tomaszbodz1913 4 жыл бұрын
Hi thanks for the wideo, When valve 3 port is set to central heating it is all the time a hot motor and there is a soft noise coming from it, It is suppose to be like this ? How do I change to heating water everything is ok
@carsonelias7432
@carsonelias7432 3 жыл бұрын
instaBlaster
@reganobrien8262
@reganobrien8262 3 жыл бұрын
Hi, i was getting no movement or resistance on the spring when all power is off the switch to go from auto and manual is lose, when turn on heating or hot water nothing is moving and boiler not firing up but pump is running. I’m a gas safe plumber just looking for some advice. Thanks
@adamcarter781
@adamcarter781 3 жыл бұрын
Body spindle may be stuck, remove head, check spindle. look inside head to see if spring is broken. Boiler should fire on HW without 3PV operation, you may need to investigate this separately. Good luck.
Central Heating - How the mid position Y plan 3 port valve works
19:26
John Ward (jwflame)
Рет қаралды 195 М.
Central Heating Wiring Made-Easy - The Basics
14:14
Adam Carter
Рет қаралды 3,4 М.
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН
Inside a Central Heating Zone Valve Actuator
12:53
John Ward (jwflame)
Рет қаралды 171 М.
W Plan - Priority Hot Water
10:15
Adam Carter
Рет қаралды 2,7 М.
Motorised Valve Fault Finding
9:08
Skill Builder
Рет қаралды 33 М.
Center Position of Direction Control Valve | Direction Control Valve Mid-Position
16:17
2 Port Central Heating Zone Valve CUT IN HALF Pt.2
11:27
plumberparts
Рет қаралды 36 М.
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН