Thanks for the comment. And nice to know you liked this
@JanPLopez993Ай бұрын
Excellent points raised, highlighting pertinent considerstions to be undertaken. Thank you!
@CIVILERABangaloreАй бұрын
You are welcome.
@esabenkeys2 ай бұрын
Excellent work 🖤♥️🖤🏆👑⭐🟥
@CIVILERABangalore2 ай бұрын
great Nice to know you liked
@SuperKillbill662 ай бұрын
where is the blog pl ?
@CIVILERABangalore2 ай бұрын
www.civilera.com/blog
@alishapradhan96022 ай бұрын
Thank you for this informative video. Could you provide the reinforcement detail in the continuous beam of different widths ?
@CIVILERABangalore2 ай бұрын
Please join my group and ask there. When free will sketch for you www.civilera.com/contact-us
@jasimscivilengineeringprac42642 ай бұрын
THANK YOU
@khalifaalnaamany93302 ай бұрын
Hello I am not a civil engineer , I m trying to build a car garage with a swimming pool on top of the garage , the garage is 10m x 6m garage with a swimming pool of 8m x 5m and 1.5m depth with six footing and pillars, what size of footing should I use to be on the safe size, thank you
@CIVILERABangalore2 ай бұрын
Please consult a Structural Engineer in your area and explain and get this designed.
@rogasianmassawe84782 ай бұрын
I would really like to use the report for reference how can I get it!?
@CIVILERABangalore2 ай бұрын
Contact me on www.civilera.com/contact-us what do you do by the way
@divyadivakar84852 ай бұрын
Well explained
@CIVILERABangalore2 ай бұрын
Nice to know you liked the video 🙂
@nramanjaneyulu28422 ай бұрын
sir if we provide more than max. Reinforcement, is there any problem? in beams, we have over/under reinforced, but in columns, no such things?na?
@CIVILERABangalore2 ай бұрын
It should not be creating congestion
@donfrancis12463 ай бұрын
Thank you Sir a ton! Please do more of such videos.
@CIVILERABangalore3 ай бұрын
sure :-) Glad that you liked it
@vandamev12123 ай бұрын
Sir, can it also be attributed to the fact that in engineered buildings, factors of safety (F.O.S) have been included in the loads and material strength and that in non-engineered buildings the mistri has coincidentally ended up with a design which just satisfies the load and moment requirements excluding the F.O.S?
@CIVILERABangalore3 ай бұрын
yes. but they are not even designing.
@nicolasmarie43984 ай бұрын
Hi. Thanks for the video. There are situation where we have to put the Longer Bar as B1 and the Shorter Bar as Distribution/B2 bars for example if there is a cantilever adjoined to the longer direction. I will greatly appreciate if you can talk more about this? Thanks.
@CIVILERABangalore4 ай бұрын
B1 need not be always short even in normal slabs. It is dependent on many things. In site it is not practical in a large building as adjacent slabs may have different orientation. For your cantilever question, see if this video has any info kzbin.info/www/bejne/bnizqWuQfteNea8si=9LUZqg4tTEkJIciA
@onaziagbese77794 ай бұрын
Fantastic
@CIVILERABangalore4 ай бұрын
thanks great to know you liked it
@saranshjoshi31674 ай бұрын
excellent
@CIVILERABangalore4 ай бұрын
Thanks for the comment and nice to know you liked it 🙂 What do you do? Are you in my community?
@kelvinonyango91775 ай бұрын
kindly share the report
@CIVILERABangalore5 ай бұрын
done
@luckyali45865 ай бұрын
Thanks I was little confused, watching ur Video helped me.
@CIVILERABangalore5 ай бұрын
Great to know the video helped you. What do you do? You are a civil engineer or were looking for a solution while building your own?
@Updatedknowledge95 ай бұрын
Sir, how can access your pdf
@CIVILERABangalore5 ай бұрын
What is your name. What do you do?
@Updatedknowledge95 ай бұрын
@@CIVILERABangalore I am a student👦📖🎒 , tomorrow is my presentation on soil machines
@CIVILERABangalore5 ай бұрын
@@Updatedknowledge9 I asked you name. Tell me that + Your email. WA number and the college.
@chtahnamte5 ай бұрын
What if the column comes in the middle fo the tank
@CIVILERABangalore5 ай бұрын
Better to avoid. If un avoidable, do proper water proofing and load take down as needed
@shamalmohammed48576 ай бұрын
Dear Sir, do you have courses in Udemy ?
@CIVILERABangalore6 ай бұрын
I have my own portal and it is course.civilera.com
@fakrudinahmed51416 ай бұрын
What is the course fee
@CIVILERABangalore6 ай бұрын
we have many programs. I suggest you check course.civilera.com for basic courses and contact me for mentoring
@mohammedsafwaan95256 ай бұрын
2:16 Hello sir, Will the load coming from rcc walls and slab of the tank not affect the footing as its density is higher than that of soil?
@CIVILERABangalore6 ай бұрын
@@mohammedsafwaan9525 Use logic and simple calculations Note 2 points 1) The density difference is minor 2) Even if concrete is denser, we are replacing quite a lot of soil with water. so water is less dense. You can calculate total weight of soil and compare with that of rcc tank + water.
@adilkhan35846 ай бұрын
Nice Video. I just wanted to ask, when you mean reinforcement at Top is usually required for depth 1000mm, I'm assuming you mean embedment depth or just the member thickness of 1000mm? Or both scenarios?
@CIVILERABangalore6 ай бұрын
Total thickness of section
@shareqinamdar89036 ай бұрын
Nice explanation
@CIVILERABangalore6 ай бұрын
Thanks
@Innotutorial6 ай бұрын
Thank you so much Sir for the knowledge
@CIVILERABangalore6 ай бұрын
hey nice to know you liked it
@aswingovind-up4mz6 ай бұрын
sir, i have an question in column design. After analyzing the column ,moment are high in top storey(mx,my value) while compare to bottom storey and at the same time the Pu value is high on bottom storey while compared to top storey . which value (PU ,Mx and My ) should take while designing a column
@CIVILERABangalore6 ай бұрын
You need to design each level of column separately Also note that you will have 26 combinations for design. Why don't you make use of our republic day offer and learn from the course? You can find it in the link below course.civilera.com/courses/etabs-superstructure?coupon=OFFER2022 Are you in my groups and emails?
@sudarshannikam52436 ай бұрын
Thanks sir for this valuable video. Sir ,please make detail video on eccentricity of Column due to reduce size of upper floor column, and eccentricity due to unequal load (due to unequal beam span around column). Which eccentricity should take account.
@CIVILERABangalore6 ай бұрын
I am not a fan of reducing size. You cannot generate it unless you apply it
@thepipsavvy6 ай бұрын
This is really an eye opener. Thank you.
@UnmeshBane6 ай бұрын
Hi all, you can use this tool to automate this Pier and Spandrel labelling in few clicks, watch this kzbin.info/www/bejne/sJSUdauFmdKbZrM
@ganeshpaudel29726 ай бұрын
Nice information. But you didn't explain why minimum reinforcement is provided at the top. Yes, it is in the code but what is the function of the top rebars? And why top rebars are not required for sections of thickness<1m?
@CIVILERABangalore6 ай бұрын
It is understood. When the section is thicker, chances of cracking are more. IS has decided it for over 1m. Same is different for BS. You can check the crack width calculations in these codes
@struct-architecture27797 ай бұрын
How we will come to know about the "concrete area required to resist direct stress" in etabs, if the column is oversized?
@CIVILERABangalore7 ай бұрын
ETABS will not show this. You need to check all your columns that shows up as 0.8%
@BariRiazRasool7 ай бұрын
Well explained and a good refresher. Thanks for throwing some light on this topic again!
@CIVILERABangalore7 ай бұрын
Happy to see you liked it 🙂
@MrJtj0077 ай бұрын
Hi sir, how do we know if there's eccentricity moment because in etabs, it considers all the members are connected to each other to the centre line,?
@CIVILERABangalore7 ай бұрын
That is a different point all together. Here we are talking about ''minimum'' eccentricity moment and this will be calculated by software based on the clause I have mentioned in the video
@zuberibrahimsultan87717 ай бұрын
Which model is more accurate, membrane or thin shell ???
@CIVILERABangalore7 ай бұрын
shell thin will be.
@zuberibrahimsultan87717 ай бұрын
@@CIVILERABangalore could you tell me why ???
@CIVILERABangalore7 ай бұрын
@@zuberibrahimsultan8771 Should be in the video. Membrane will replicate Yield line theory behavior and shells would do stiffness based
@zuberibrahimsultan87717 ай бұрын
@@CIVILERABangalore got it. And thanks
@ashlardesignandinfra17747 ай бұрын
Sir truly amazing
@CIVILERABangalore7 ай бұрын
hey thanks for your kind words 🙂
@ZahidBadgujar7 ай бұрын
Hi can someone suggest the best book fir RCC DESIGN, thanks in Advance
@CIVILERABangalore7 ай бұрын
Text books are rarely useful for a comprehensive learning. Any ways, you can refer Professor PC Varghese's book or that by Prof Pillai and Menon or Dr Subramaniyom
@superindia48183 ай бұрын
B. C. Punmia
@gunaseelanm83358 ай бұрын
The behavioral change of the structure was well exhibited when the support positions were altered, excellent video for the beginners👍.
@CIVILERABangalore8 ай бұрын
Glad you liked it! I tried to explain some thing different which will be beneficial for beginners :-)
@nadeemvision8 ай бұрын
Very informative. Thank you sir.
@CIVILERABangalore8 ай бұрын
Nice to know you liked it 🙂
@raghuveerar27888 ай бұрын
In rc structural wall system can we model the beam instead of spandrel for high rise building as per is code??
@CIVILERABangalore8 ай бұрын
Depends on the size and location of beams. Are you referring to Mivan shuttering system
@vitrovogan96358 ай бұрын
The explanation is really very beautiful.
@CIVILERABangalore8 ай бұрын
Hey thanks for your comment. Happy you enjoyed the video. Are you in my group?
@vasubhadania8 ай бұрын
Can anyone please provide me with an example of safe where it is possible to create isolated footing without a top reinforcement......!??!! Small large size doesn't matter just create one isolated footing in safe where top reinforcement is not required.......!!!
@CIVILERABangalore8 ай бұрын
Generally Top rebars are not needed in Isolated footing if it is designed as a singly reinforced section. It is advisable to design as a singly reinforced section. So if you do that, the only need of top rebar in isolated footing is when the depth is more than 1000mm as per IS 456.
@vasubhadania8 ай бұрын
@@CIVILERABangalore i am using less than 1000 mm depth, even when forces is low..... there is no way where i can get zero reinforcement in top (with design strip or in FEM method) while checking for reinforcement after design in SAFE......here i am not talking about manual design....
@CIVILERABangalore8 ай бұрын
@@vasubhadania Am sorry. I cannot understand you. 1000mm bars your won't get any where. I meant the depth. Manual or software, you don't need top rebars unless it is doubly reinforced due to lack of adequate depth
@vasubhadania8 ай бұрын
@@CIVILERABangalore sorry i actually ment 1000 mm depth.....i am trying safe because safe can also be used for combined footing..... While using safe there will always be top reinfo.... I want to resolve that.... In short i am trying to get no top reinforcement in safe but why is there always top reinforcement.....i want to know that reason..!!!
@CIVILERABangalore8 ай бұрын
@@vasubhadania You are perhaps over using SAFE. You just analyse and zone the forces and dont use the design oprion
Explained very well. Thank you for sharing the knowledge
@CIVILERABangalore9 ай бұрын
Thanks for the comment and great to know you liked it
@indramlimbu68869 ай бұрын
@@CIVILERABangalore welcome sir. Keep uploading such videos, sir.
@ramonbaccomperi78719 ай бұрын
Hello, such an informative video. I want to know how you will determine if etabs use the gross area or the tributary area for the steel reinforcements calculation. Thank you
@CIVILERABangalore9 ай бұрын
Thanks a lot for your comments. Am a little concerned about your question as I feel that your understanding is slightly different. The tributary area comes in to picture when you calculate the load. Am not 100% sure what you meant though. The comparison wrt rebar area is gross area vs required area to take the actual axial stress.
@ramonbaccomperi78719 ай бұрын
So tributary area is the area where the load is acting if I'm right so it's different from the actual area or?
@CIVILERABangalore9 ай бұрын
Am not sure of your question @@ramonbaccomperi7871
@ramonbaccomperi78719 ай бұрын
Please I will like to know the meaning of tributary area.
@CIVILERABangalore9 ай бұрын
@@ramonbaccomperi7871 See this video kzbin.info/www/bejne/gnfThIdnbKtoeM0si=nt64sgUYbO2Z84h2 I have mentioned about an area in this
@mohammedraihanan58589 ай бұрын
Sir could you please make an vedeos on side face reinforcement for beams
@CIVILERABangalore9 ай бұрын
Let me try 🙂What do you do now?
@mohammedraihan45808 ай бұрын
@@CIVILERABangaloresir now I am working as design engineer.
@CIVILERABangalore8 ай бұрын
ok which one and location
@mohammedraihan45808 ай бұрын
@@CIVILERABangalore Bangalore Sir
@Er.RamanjaneyuluNingampalli9 ай бұрын
Great video
@CIVILERABangalore9 ай бұрын
thanks for your comment
@MudgalS.R9 ай бұрын
All videos are very informative, and nothing is coppied as pleples use to do, its your hard earned experience 🙏🙏
@CIVILERABangalore9 ай бұрын
Hey nice of you to see your honest comment 🙂 It inspires when people comments facts. You can also subscribe here for regular updates and joining group www.civilera.com/contact-us