a little bit of ice it is normal around the middle of the coil ? i have a aquarium maybe the evaporation dont help .. does coil have some ice sometime ?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 15 сағат бұрын
Please send a video by mail.
@mjyumping
@mjyumping Күн бұрын
Sir I'm trying to take the fan blower off my indoor cassette unit. I've removed the nut and the special washer but the fan blade won't come out from the shaft
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Күн бұрын
Need to use WD40, BECAUSE the shaft is rusted & stuck. Tight the nut only top thread, then knock gently it will come down.
@mistergordon9613
@mistergordon9613 7 күн бұрын
error CL
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 7 күн бұрын
If you're encountering a CL error on your TCL inverter split unit, it typically indicates a communication problem between the indoor and outdoor units. Here are a few troubleshooting steps you can try if you have technical knowledge otherwise call a professional.. 1) Power off and restart: Turn off the air conditioner at the circuit breaker or disconnect it from the power source. Wait for a few minutes, and then turn it back on. This simple reset may resolve the communication issue. 2) Check the remote control: Ensure that the remote control's batteries are functioning correctly and properly inserted. Weak or dead batteries can sometimes cause communication problems. 3) Verify the display: Take note of any additional error codes or error messages displayed on the unit's control panel. They may provide more specific information about the issue. Refer to the unit's manual or contact TCL customer support for assistance in interpreting the error codes. 4) Inspect the wiring: Examine the wiring connections between the indoor and outdoor units. Look for any loose, damaged, or disconnected wires. If you're comfortable doing so, you can try reseating the connections or fixing any obvious issues. However, if you're unsure or uncomfortable working with electrical components, it's best to contact a professional technician. 5) Power supply check: Ensure that both the indoor and outdoor units are receiving the appropriate power supply. Check the circuit breakers or fuses related to the air conditioner and verify that they are not tripped or blown.
@sajo_86
@sajo_86 15 күн бұрын
How to change to fahrenheit?
@technicalhelal4185
@technicalhelal4185 15 күн бұрын
Thanks
@pjthe1
@pjthe1 19 күн бұрын
My midea 1 ton inverter is showing P0 error and compressor just starting abd stopping..?? What is the problem?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 19 күн бұрын
Is the fan running or not?
@Eric-z5h
@Eric-z5h 23 күн бұрын
Error code 79 on my TCL window unit model w10w9e2-3??
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 23 күн бұрын
Please tell me what is happening in your ac unit.
@Eric-z5h
@Eric-z5h 23 күн бұрын
Not cooling properly, compressor cycling too fast cant change anything on display.. e.g. - display says 79, its stuck on auto mode and low fan soeed
@Eric-z5h
@Eric-z5h 23 күн бұрын
Speed*
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 23 күн бұрын
@@Eric-z5h reset the unit once
@Eric-z5h
@Eric-z5h 22 күн бұрын
@@Rehankhan_HVAC_TIPS done it several times... Just took circuit board out.. got some burnt connections looks like... Needs a new one.
@Rignold
@Rignold 28 күн бұрын
Very simple and clear video. Thank you.
@thomasusheriii971
@thomasusheriii971 Ай бұрын
So I cleaned the filters they pulled right out and they washed right off.They were filthy and now its like a brand new system. I have a split unit.
@VishalKhan-wo9yg
@VishalKhan-wo9yg Ай бұрын
Rehan Bhai vishal apna nb do mujhe
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
Bhai kaisa ho
@VishalKhan-wo9yg
@VishalKhan-wo9yg Ай бұрын
@@Rehankhan_HVAC_TIPS bhai thik he aap btao
@allelingtv
@allelingtv Ай бұрын
anong chemical gamit mo sir
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 5 күн бұрын
Sorry didn't understand?
@richardmstephen4701
@richardmstephen4701 Ай бұрын
Super 🎉
@user-dd8jn9lj1d
@user-dd8jn9lj1d Ай бұрын
미래소년 코난
@haponesongbarok
@haponesongbarok Ай бұрын
Big help
@haponesongbarok
@haponesongbarok Ай бұрын
Please upload more tutorial videos for 4way aircon with unit. Like daikin or toshiba and mitsubishi and also hitachi
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
kzbin.info/www/bejne/pafOmHikrJuSnKMsi=kMOZ8WmNR8FOiocF This is a daikin tutorial.
@haponesongbarok
@haponesongbarok Ай бұрын
Big help 🙏
@CJ-vg4tg
@CJ-vg4tg Ай бұрын
Hi. If I disconnect the outdoor unit and measure the indoor unit N to S and it reads 24v DC but no fluctuation does this mean it is still ok or should it be fluctuating? E5 error code. Thanks!
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
1. Firstly, the IDU and the ODU should be matched and connected properly. 2. Observe the main external control panel, turn on the air conditioner, three lights are all lighted up then off and the relay pulls in. If not, it is power supply problem. 3. Connect the black signal line S to terminal N of ODU. Turn on the A/C, if "E5" is still reported, the main external control panel need to be replaced. If "E5" is still reported at this time, go to step 4. 4. Change a new main internal control panel, if the error code E5 remains, then the problem should be on the main external control panel.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
There will be no Fluctuations, because you have removed the communication cable from the outdoor unit. Only one side of communication is receiving That's why it will not fluctuate.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
Did you check the outdoor unit N to S, after disconnecting the S from the outdoor unit. What is the voltage from the outdoor side?
@CJ-vg4tg
@CJ-vg4tg Ай бұрын
​​​@@Rehankhan_HVAC_TIPS brilliant. Good to know thanks. I will check the signal from the outdoor unit with it disconnected from the indoor shortly. Thanks for your rapid reply. I also have 2 of the identical units working correctly so can compare values. It did initially trip the circuit breaker before the E5 occurred.
@CJ-vg4tg
@CJ-vg4tg Ай бұрын
​@@Rehankhan_HVAC_TIPSJust checked it and no DC voltage from S on the outdoor unit. Worth checking the fuse on the odu? Or is it pretty much dead? I'll remove it and have a look in a day or 2. Don't have easy access to it. 👍
@somethingorother03
@somethingorother03 Ай бұрын
The music is too loud
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
Sorry for the disturbances.
@Slayer_Editz180
@Slayer_Editz180 Ай бұрын
Thanks i was worried for my AC
@user-zc6dq8vv8n
@user-zc6dq8vv8n Ай бұрын
What is difference between 4 plus and 5plus sir.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
Sorry i didn't understand
@user-zc6dq8vv8n
@user-zc6dq8vv8n Ай бұрын
@@Rehankhan_HVAC_TIPS bluestar vrf model 4plus and 5plus. This video is which model sir.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
This is V4 Model
@user-zc6dq8vv8n
@user-zc6dq8vv8n Ай бұрын
This is not v sir, it roman number 5
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
Please contact me by mail✉️
@prameshpawar865
@prameshpawar865 Ай бұрын
Please halp me
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS Ай бұрын
Ok
@prameshpawar865
@prameshpawar865 Ай бұрын
Ivrffanv4108274 ko repair karna hi
@moonmoonreview7788
@moonmoonreview7788 2 ай бұрын
Dead econavi sensor
@Jim-vi5wi
@Jim-vi5wi 2 ай бұрын
Simply unscrewing and pulling as shown, you stand a high chance of snapping the plastic tabs at the top/rear of the cover.🛑
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 ай бұрын
Sorry i didn't understand😉
@vikranthrana3019
@vikranthrana3019 2 ай бұрын
I have Daikin ac if i keep on below 25 the ac is forming ice , it was good at beginning but after 2-3 months its started to get freezing problems
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 ай бұрын
There is a gas leakage in the system, please contact the installation technician or company.
@azadkhan6423
@azadkhan6423 2 ай бұрын
Thanks bro
@zainbhatti4177
@zainbhatti4177 2 ай бұрын
OA error what is the reason behind
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 ай бұрын
Please let me know the model number and type of ac.
@kskandaraaj4643
@kskandaraaj4643 2 ай бұрын
👍👍👍
@anandmishra-wl3ks
@anandmishra-wl3ks 2 ай бұрын
thanks for the knowledge sir
@anujsharma9230
@anujsharma9230 2 ай бұрын
Facing c1 01 error in daikin cassate ac indoor outdoor is normal contactor operated
@MarquezRizzich
@MarquezRizzich 2 ай бұрын
Cara mengatasi kodee eror eo
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 ай бұрын
The ac unit is getting overloaded either from the indoor side or the outdoor side. Or Condenser is block
@abhinav155
@abhinav155 2 ай бұрын
Excellent video
@manishdutta1084
@manishdutta1084 2 ай бұрын
Bhai how can stop the auto ignition system because i face tension I earlier using lighter i want to close auto system n try only lighter for flaming fire
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 ай бұрын
Remove the auto ignition connector.
@bhagatsinghfan4037
@bhagatsinghfan4037 2 ай бұрын
Don't touch PCB with your naked fingers. Because capacitor hold a charge and it will shook you very badly 🙏🏻
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 ай бұрын
Thanks brother
@user-cu4es4jh9w
@user-cu4es4jh9w 2 ай бұрын
Go with Daikin.
@subhasismandal4180
@subhasismandal4180 2 ай бұрын
In my case for 10-15 mins it shows f3 error code in day time and after that it automatically goes to temprature 31 and then i again set it to 24 and it starts cooling
@roshnigupta6362
@roshnigupta6362 2 ай бұрын
Sir f3 is showing in the ac only during day time. When we are using the ac in night it is working properly only. What should we do?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 2 ай бұрын
According to this F3 Error, it seems that your compressor is getting over heat or the discharge sensor is having the issue. Step to follow: 1) Need to service the outdoor unit, if you are still getting the same issue call a professional to check the sensor & compressor condition.
@user-bu8hb1lf2w
@user-bu8hb1lf2w 3 ай бұрын
Hi P0 E10
@ankurmistry9813
@ankurmistry9813 3 ай бұрын
Error code ER is not there
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Are you facing the error ER in your Ac?
@Burhanenterpries
@Burhanenterpries 3 ай бұрын
@mousumighosh1421
@mousumighosh1421 3 ай бұрын
My newly installed panasonic ac showed h52 when it was turned off.. What to do sir? Bought it just on 13th April
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Try to claim the warranty & exchange the unit. That will be best, to check the unit needs to open indoor and outdoor units . As it's a new ac it's better to replace the unit. Thanks
@mousumighosh1421
@mousumighosh1421 3 ай бұрын
@@Rehankhan_HVAC_TIPS but sir whenever I'm checking the error with remote nothing is showing.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
@@mousumighosh1421 your ac is cooling or not?
@mousumighosh1421
@mousumighosh1421 3 ай бұрын
@@Rehankhan_HVAC_TIPS cooling as usual
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
@mousumighosh1421 If it's cooling then thier is no issue, 1) check the if the ac is cooling or not if it's cooling it means no issue in ac. 2) Check if their is any ice formation in small pipe. 3) check outdoor unit is working continually or not, if running then need to check the outdoor unit. 4) if ac is cooling please don't do any remote setting, just use as normal.
@mousumighosh1421
@mousumighosh1421 3 ай бұрын
My newly installed ac showed H58 after 4days. Shout i get it to be repaired?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Check if it's a cable issue no problem need to connect properly , if there is a PCBs card fault or sensor fault better to replace the ac. As it's a new ac unit.
@mousumighosh1421
@mousumighosh1421 3 ай бұрын
@@Rehankhan_HVAC_TIPS cable issue means? Wiring fault?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
May be cable between indoor & outdoor units not fixed properly. If there is no issue with cable then try to change the unit.
@bdellis58
@bdellis58 3 ай бұрын
I also bought the Midea 8000 BTU July 2023 when my house AC went out. It is very cheap to operate. So that is a plus. But just turned it on first time in 2024 and not working. NOT COOLING and error code 07. Called customer support and they will not honor the warranty unless I send a copy of receipt. Which I don't have anymore. So for around $400 I got about 4 months use out of it. Also had mold issues as most customers are noticing on the blower fan. Not happy.
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Sir it depends on the policy according to the region. Please check any other dealers, they can help you.
@amirahmad2789
@amirahmad2789 3 ай бұрын
Charge kitna h cassette ac service ka?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Kha pa
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Location
@challahemanth
@challahemanth 3 ай бұрын
H85 error code is displayed/blinking after the AC is turned off.
@user-cu4es4jh9w
@user-cu4es4jh9w 3 ай бұрын
Fraud hai Panasonic
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Sorry kiya hua bhai
@ArupDhar-wo8gj
@ArupDhar-wo8gj 3 ай бұрын
H85 error ka solution Kya hai??
@challahemanth
@challahemanth 3 ай бұрын
There is no description for H85 error code in the list. Neither is it available online. Should I contact customer care?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Is it a new ac unit?
@guillermobuendiabrborich4323
@guillermobuendiabrborich4323 3 ай бұрын
Que tan bueno es este modelo?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Sorry didn't understand?
@mehmoodghouri153
@mehmoodghouri153 3 ай бұрын
Good performans
@everything7273
@everything7273 3 ай бұрын
Compressor 134 yah wala oil Dal sakti hai kya vacuum pump mein
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Vacuum pump ma dal sakta ho bhau, No issue.
@memine3148
@memine3148 4 ай бұрын
Just today our pcb has busted. where can we buy for replacement since we do not have the exact model of our unit. could you please help us. Thanks
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 4 ай бұрын
It depends on the location you're leaving, I will definitely try to help you. Can you provide the indoor unit model no.
@memine3148
@memine3148 3 ай бұрын
@@Rehankhan_HVAC_TIPS @Rehankhan_HVAC_TIPS . Thanks for the reply. Location is in San Carlos City, Negros Occ, Philippines. The model number of the unit is AR-09JVFS
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 3 ай бұрын
Please send the picture of Burned pcb card.
@memine3148
@memine3148 3 ай бұрын
@@Rehankhan_HVAC_TIPS pictures can be send here in you tube. help me how i can send you the picture.
@memine3148
@memine3148 3 ай бұрын
@@Rehankhan_HVAC_TIPS I uploaded a video of the burnt pcb. Please try to see it for yourself so you recommend where i can buy the new one. thanks
@emmanuelorieh6144
@emmanuelorieh6144 4 ай бұрын
what does E4 error mean and how do I fix it?
@Rehankhan_HVAC_TIPS
@Rehankhan_HVAC_TIPS 4 ай бұрын
System abnormal 1) Check if the high pressure valve and low pressure valve open . 2) Check if the refrigerant is short, then recharge. 3) Check if the temperature sensor on the outdoor condenser is loose or broken. 4) Replace the indoor main PCB.