Make sure you register the equipment for warranty the indoor coil will leak
@FEDERALSIGNALTECH11 күн бұрын
I have the same thing but it's a straight cool unit and it's matched up with an AMANA AIR COMMAND AMVC 97 Gas furnace with polorized air filter by DYNAMIC air quality solutions.
@FrancoBarbagallo111 күн бұрын
Very nice
@FEDERALSIGNALTECH10 күн бұрын
@@FrancoBarbagallo1 the only thing is we don't have the communicating thermostat but it's still good for the house and it's going on its third year of service and it's very reliable comparing the the single stage system that it replaced that had a bad TXV.
@jacobflanigan634313 күн бұрын
How does the defrost cycle work on your dual fuel system since you have a 2 stage gas furnace?
@FrancoBarbagallo111 күн бұрын
For this particular combination, this system is fully communicating and balance points can be easily adjusted from the touchscreen S40 thermostat We configured this one to run heat pump only and not allow gas furnace when outdoor temperature is 45F or above and to intelligently switch between heat pump and furnace as needed down to 25F and below 25F to go straight gas. Whenever the outdoor unit defrosts the furnace can take over if heating is needed The Lennox S40 communicating control is really cool’s for communicating heat pumps
@bills694614 күн бұрын
Wait. What? Chicago winters are above 30 degrees 70% of the time? Seriously? I must have been thinking of the other Chicago. The one off the lake.
@FrancoBarbagallo111 күн бұрын
@@bills6946 Winter is being referred as all the days where heating is used in the Chicagoland area which are a lot of days The average seasonal mean temperature for winter in Chicago is 28.1°F. The average daily high temperature is around 30-38°F Temperatures can get a lot colder of course, but we break the heating season in total hours the vas majority of the total hours when heating will be used to some degree will be above 32F. Making this dual fuel solution and great option that will provide comfort and efficiency in mild and very cold days
@kangaroogod17 күн бұрын
Such great technology that is dumbed down by on non modulating indoor blower
@FrancoBarbagallo111 күн бұрын
Despite it not being perfect this combination is a terrific value for the investment, as you get in to inverter technology that works with any new or existing gas furnace and qualifies for substantial rebates and tax credits We get amazing feedback from our customers on this systems. Of course it can always be more advance or high tech but it comes at a cost Thanks for watching and commenting
@innamirutenko146625 күн бұрын
nice video can you tell me how much I can charge to the customer to replace two 24000 air handler and one condenser 48000 Btu Mitsubishi hyper in up state new York?
@FrancoBarbagallo125 күн бұрын
I wouldn’t know pricing can vary drastically market to market and home to home and depending on the level of service and guarantee provided This project was about 28k in 2023 in Chicago suburbs including utility rebates Unfortunately prices are on a non stop climb
@victormilla152225 күн бұрын
Thanks Franco
@nepalitechreviews5534Ай бұрын
At what outside temperature it will switch to furnace
@bills694614 күн бұрын
You manually set the change over temperature usually in the thermostat configuration settings. Increments of five degrees.
@FrancoBarbagallo111 күн бұрын
For this particular system the outdoor unit comes preset to switch over to gas heating when the outdoor temperature falls to 32F or under or when the heat pump can’t keep up with thermostat setting regardless of outdoor temperature.
@jimmcalister4413Ай бұрын
why do you have your gauges and amp meter on the unit an not your laptop connected with Maintenance tool (MT)? Maybe the gauges are on there because you just completed adding the trim charge??? Did you do a Mitsubishi start-up? I can guarantee you that system will need added refrigerant even without calculating line set length my guesstimate would be 3lb add approximately 2-4lb for the line set (guesstimate from experience but why a DSB is needed. Your computer with MT will tell you the pressures and temp of the senses in the condenser and indoor units. This applies if in the USA if not Please disregard: please say you built this system on DSB because a 1 hour recording on MT submitted through your DSB is how you get the 10 year warranty or 12 years if you're a Diamond Dealer. Friendly questions from your Mitsubishi DSG
@alexkrokhov965225 күн бұрын
dude you are wrong, those units precharged for 250 feet of lineset. And its NOT commercial type of citi multi, computer not needed
@FrancoBarbagallo111 күн бұрын
This video was taken just before completing for demonstration. Another technician (our Mitsubishi supervisor) returned later in the day to perform a final calibration, testing and adjustments. About 5lb of refrigerant were added during final inspection. Customer got a 12 year guarantee on parts and labor from us Since installation we have returned once for a connectivity issue with wifi on the kumo cloud but everything was working great (homeowner got a new router and disabled 2.4ghz WiFi band)
@FrancoBarbagallo1Ай бұрын
It can be adjusted, but default balance point is 32F to switch over
@wallaceburroughs3660Ай бұрын
what temp does furnace kick on
@FrancoBarbagallo111 күн бұрын
By default is present at 32F outdoor temperature, however this can be adjusted down Balance points will vary drastically from building to building depending on how well insulated and air tight home is and on how sizing was designed and how much airflow ductwork can handle
@nepalitechreviews5534Ай бұрын
What’s your house sq feet? How it’s running now ? Which state u at ?
@FrancoBarbagallo1Ай бұрын
This is a clients home, in Chicago suburbs. This home was about 2300 sq ft and it’s running great
@michaelcash9258Ай бұрын
👍
@LeBenfordАй бұрын