Sir pls am tired of using trial version of Siemens. I want a purchase. How should i go about it. Pls help
@MenOfCulture89917 күн бұрын
thank you. where did you get the 141mm?
@muhamedpasic837 күн бұрын
I took a specific example here. A gear is monitored on the encoder shaft, so when the encoder makes one revolution and the gear makes one revolution, that is a path of 141mm. The circumference of the gear is 3.14*R, the R-diameter of the gear, so the larger the R, the larger the circumference of the gear. In my example, the diameter was such that when the circumference is calculated, I get 141mm. There will be a different scope for some other gear
@tolentinojohnnathaniel52608 күн бұрын
Do you have the installer software for wincc rt advanced v14?
@mansureee944910 күн бұрын
Video nice sir but please make with voice
@drinski672021 күн бұрын
Can process tag be real number? You used integer.
@muhamedpasic8318 күн бұрын
yes, you can use REAL
@user-je8wm3jq3u21 күн бұрын
USFUL
@chrisredfield869824 күн бұрын
Thanks for the effort but where's the part where u create the AT tag in s7 300 using SCL ? i can't find that part in the video ? Thanks in advance.
@muhamedpasic8324 күн бұрын
Watch the video from 0:58 to 1:28 minutes
@kendilnourelislem306826 күн бұрын
I need more explanation about the fonctions in the 2 network 🙂
@muhamedpasic8324 күн бұрын
The value obtained from the TC module to which the thermocouple probe is connected for temperature measurement is multiplied by 10. So, if the actual temperature is 25 degrees Celsius, you will see 250 degrees Celsius in the PLC program. Therefore, this value is divided by 10 to get the actual temperature value. Because in the TC module, automatic scaling of the temperature value is performed, but only increased 10 times, and therefore it must be divided by 10
@slobodanjovanovic1986Ай бұрын
Veliki pozdrav. Mozete li pokazati kako se na Hmi ekranu kreiraju datoteke pri cijem se kliku ulazi u podesavanne razlicitih parametara
@suriyat8773Ай бұрын
Absolute Encoder with PLC S7 1200
@muhamedpasic83Ай бұрын
same procedure
@ahmetdumlu25Ай бұрын
dosyaları paylaşa bilirmisiniz
@jonathasmanetticosta9393Ай бұрын
Esse vídeo seu é massa. Tem encoder que tem 1 bit de presset. Encoder assim, como faço para resetar?
@snowflake7233Ай бұрын
thanks very much!!!!!!!!!!!!!!
@jask320Ай бұрын
Oh man... thanks. I spent an hour to find this
@loicnzundja656Ай бұрын
toujours rien sa me casse la tete . puis avoir votre adresse mail s'il vous plait
@loicnzundja656Ай бұрын
non même manuellement il sort la même erreur
@muhamedpasic83Ай бұрын
Create a new project, do not add or create anything in it, and click "accessible devices" and see if you can connect to that CPU
@muhamedpasic83Ай бұрын
The PLC is with PROFIBUS, are you using the same cable as I am in the video, and what type of PLC is it
@loicnzundja656Ай бұрын
Ethernet And the type of plc is Siemens s71200
@loicnzundja656Ай бұрын
Can I have your email ? Please
@muhamedpasic83Ай бұрын
@@loicnzundja656 The IP address on the PLC and the ethernet cable should be in the same subnet, eg 192.168.0.x. x can be for PLC 1 and for ethernet cable 10. TIA Portal should automatically assign the appropriate IP address for ethernet, but if you have a problem, add it manually. Manually assign an IP address to the network adapter
@yahya979Ай бұрын
فين الصوت
@liteglow2000Ай бұрын
Cant get this to work !! Any advise ? when I use "Count" my ID1000 is showing 010101. If I change to "Frequenzy" it show nothing. So what you do here dont work for some reason, I dont get the number you have when you spin it around, I only get 01010101
@user-iq4mu1is5dАй бұрын
بالتوفيق ان شاء الله مجهود رائع
@vikashsaxena99072 ай бұрын
no sound.....looks like u r explaining!!!
@j5k2 ай бұрын
thx
@user-zo7ie7kj4u2 ай бұрын
Thank you for the video. Thank you for taking the time to record this video! Have you ever used this functionality in practice? If yes, in what situations?
@muhamedpasic832 ай бұрын
software units is used when two or more programmers are programming the same PLC at the same time. Everyone programs their part independently of the other
@chrisredfield86982 ай бұрын
I appreciate the time and effort you've put into this 👊 keep going. But i have a small QUESTION 😁 This part is the command part and we still need to do commissioning. Do you do it in TIA portal or on the drive itself 🤔
@digvijayjangam85272 ай бұрын
I use to this method by can't solve our problems
@muhamedpasic832 ай бұрын
Check if the HMI and computer have the same subnet, for example 192.168.0.x, then check if the same HMI as the actual HMI is selected in the program (TIA Portal). The signs must be the same as these Siemens markings, for example 6AV6 647-0AK11... Check the ethernet cable
Svaka vam čast na vašim videima,skroz profesionalno. Za nas amatere dobro bi bilo i glasovno objasnjenje,od velike pomoci.. Svaka vam cast i sve pohvale
@Alex6ix-oc4lt3 ай бұрын
Thanks for the video, was really helpful.
@Alex6ix-oc4lt3 ай бұрын
Can I contact you to verify my work ?
@Alex6ix-oc4lt3 ай бұрын
For consultation please
@vorapobautomation97603 ай бұрын
How to enable Active line Infeed direct from CU320 not via PLC ?
@vorapobautomation97603 ай бұрын
How to enable active line infeed in DCC ?
@muhamedpasic833 ай бұрын
kzbin.info/www/bejne/g6CbimV8Z7Sgq8U
@slobodanjovanovic19863 ай бұрын
Dobar dan. Da li drzite casove Plc programiranja on line?
@muhamedpasic833 ай бұрын
Dobar dan, trenutno ne, zbog obaveza
@ahmeraslam12393 ай бұрын
Where is encoder address? Piw
@muhamedpasic833 ай бұрын
It's 3:41 minutes into the video. LADDER=256, it is the starting address of the telegram used by this encoder. This telegram uses 4 bytes, which means that the position of the encoder will be recorded at the address from 256 to 259
@matiasvidelagonzalezidh70914 ай бұрын
Como hicite para que cuando dejaste de mover el encoder los valores fueran 0?
@muhamedpasic834 ай бұрын
Set the type of counting to "frequency", watch the video again from 1:15
@liteglow2000Ай бұрын
@@muhamedpasic83 When I use Frequenzy, my ID1000 is not updating at all. Thank you for any input or help, I have tried for days without any correct output.
@mohammedrezk80724 ай бұрын
be proud of your country , Bosnian not croatian ....you're muslim origin anyway.
@muhamedpasic834 ай бұрын
I am proud to be Bosnian, I wrote Croatian-Bosnian because there is no Bosnian language in TIA Portal, but there is Croatian language. And the Croatian and Bosnian languages are very similar. Proud Bosnian...
@mohammedrezk80724 ай бұрын
@@muhamedpasic83 that's it glad to see your tutorials anyway
@ceylontruckers84284 ай бұрын
Have you a any idea encoder programming with factory io ?
@user-po2dg1rt4v4 ай бұрын
Excellent video but slight error. The number entered at LADDR is the hardware address as found in the "System Constants" and not the physical address of the inputs. Your video at the end shows a decimal number which converts to Hex 8090 this has to be at 0 for correct operation. Thanks for the video though it was very useful. Hope this helps anybody else who uses it.
@Sh_Firouz4 ай бұрын
🙏🙏🙏🙏🙏🙏
@user-js1me9ye7k4 ай бұрын
What version of TIA Portal do you use?
@muhamedpasic834 ай бұрын
this video was recorded with V15.1
@Saylusman5 ай бұрын
Thank
@Alext23105 ай бұрын
Thank you!
@mohammedrezk80725 ай бұрын
i don't understand why Status word is working as Little Endian and Control as Big Endian.
@PedjaPedja-xg5mi5 ай бұрын
Ovo je odlicno. Hvala puno 🎉
@user-in7ym2oo3d5 ай бұрын
thank you for the video, i was just wondering if you can send me the code, because i am working on a similar projet, thank you in advance.
@saleemahamed63526 ай бұрын
Dear Sir, Kindly Post video for the following. 1. S7-1200 PLC interface with Mettler Toledo IND570 via Profinet Measureing "Net Weight" & "Gross Weight" & Device Status". How to dispaly in the HMI KTP1200 Basic? 2. S7-1200 PLC interface with Sinamics V20 Inverter via Modbus RTU RS485 Protocol - Start, Stop, Set frequency, Actual Frequency. How to dispaly in the HMI KTP1200 Basic? Thanking You
@muhamedpasic836 ай бұрын
Soon
@denisdurakovic12636 ай бұрын
Trebo si samo još Tag table pokazati
@dragandedic776 ай бұрын
👏wonderful
@hakuzu886 ай бұрын
Hi can we calculate the speed mesure with counting mode ??
@muhamedpasic836 ай бұрын
No count mode for speed, you have to use "frequency" mode. See the attached link kzbin.info/www/bejne/poXckqWmrbFpsM0
@hakuzu886 ай бұрын
I have another question , can we mesure the lenght and the speed with hsc1 and with the same inputs , or ??@@muhamedpasic83
@muhamedpasic833 ай бұрын
@@hakuzu88 No, you need to have two HSC
@HAT-ny1zu6 ай бұрын
can you please tell me why we need to multiply it by 10 ?
@muhamedpasic836 ай бұрын
Because the TC module scales the input signal coming from the thermocoupler, so that the temperature value is 10 times higher than the actual value. So that value must be divided by 10 to get the actual temperature value
@HAT-ny1zu6 ай бұрын
@@muhamedpasic83 thank u so much <3
@youssefmeziani607 ай бұрын
I need this project, could you send or share it please ?