Thanks I have same problem 16w I put oil and was licking from the part
@sexyman88
@sexyman88 2 ай бұрын
Hey bud, I just replaced my board because I was having EC faults. However now with the new board the EC issue is resolved but I’m getting an AO fault and my fan won’t start up. I plugged everything in exactly where it was on the old board, but no solution in sight to get the fan to start up. Any suggestions?
@stkbkr1
@stkbkr1 2 ай бұрын
Thanks man! No sh%t about that service light.
@TheZaxx
@TheZaxx 2 ай бұрын
Walmart did this for me one time, but the plastic bag/envelope was open at the top and water got into it. The ink ran.
@thekop9049
@thekop9049 5 ай бұрын
Just put in the glove box😂😂😂
@elviscollector
@elviscollector 6 ай бұрын
I went in to get one & the employee was Telling me how to circumvent the warranty & rip Walmart off.. i said no thanks..
@silverdragontaylir8252
@silverdragontaylir8252 7 ай бұрын
Genius
@rl8185
@rl8185 8 ай бұрын
That humidifier is designed to be installed on the return air side in addition you don’t need the pressure switch If you have the humidistat installed.
@mickeyflanagan4019
@mickeyflanagan4019 11 ай бұрын
Can i unplug it to bypass it just to see if that is the problem?
@CraigBuffington
@CraigBuffington Жыл бұрын
And he did all that before you finished one beer?
@jhargrove1108
@jhargrove1108 Жыл бұрын
Maybe some WD-40 and black paint.
@ncneeds
@ncneeds Жыл бұрын
A
@donovanwilliams4545
@donovanwilliams4545 Жыл бұрын
Thank you sir!
@newedition4376
@newedition4376 Жыл бұрын
My heater displayed the same “Sb” error as GTCGreg. I also misread the Sb code as temperature “56”. I followed the same cleaning steps, using CRC brake cleaner and the Sb code and service LED is no longer displaying. This method fixed my issue. I am still grateful for this video. If I needed to replace the boards, these instructions were on point. Thanks!
@TheChefef
@TheChefef 2 жыл бұрын
I had the same error code bought a new pressure switch installed it same thing it only runs for a minute and stops same code ,turns out to be a firmware update needed I’m going to try that next mine is a10kw
@GTCGreg
@GTCGreg 2 жыл бұрын
Had a similar problem with my Hayward heater. The service light would come on and the display would read Sb. At first I thought it was reading 56 but then found that Sb is the error code for a problem with the display board. I removed the board and inspected it for any water damage or corrosion but the board looked pretty good. I did notice a coating of what looked like white power on the top (led side) of the board. I sprayed the board with some CRC Break Cleaner and wiped it down with a soft cloth. I reinstalled the board and the heater works fine now. Not saying that this will fix all problems, but it's worth a try before you spend $250+ for a new board.
@remysolar9407
@remysolar9407 2 жыл бұрын
Mine lasted six months.
@razorro
@razorro 2 жыл бұрын
Have had this model for 3 years now and I think the Solenoid valve just went, how do I know if the pressure switch went also?
@charlesmcfarland1430
@charlesmcfarland1430 2 жыл бұрын
I dont have the HUM terminal. I have G C W Y R. Connected White wire to C. Where should Red wire connect
@AndrewKouns
@AndrewKouns Жыл бұрын
Did you ever find an answer for this?
@movaughn20
@movaughn20 2 жыл бұрын
Well a hair over a year, any luck with the value? I luckily found receipt and exchanged one year on the exact day, for a replacement. The new one dies if truck isn't started for 3 days with dash cam left on. Curious what the known difference in "value" line to standard everstart? Great tip!
@BigBeef
@BigBeef Жыл бұрын
Much less lead inside.
@andrewhaubois9972
@andrewhaubois9972 2 жыл бұрын
I put mine on my return duct and I am not getting my desired levels of humidity. Should I switch it around?
@charlescampbell453
@charlescampbell453 2 жыл бұрын
The C is for common or your ground there is no voltage there.
@SmokinLoken
@SmokinLoken 2 жыл бұрын
You are correct. I was going to comment the same thing. C is for common, not constant 24v.
@chriscales32
@chriscales32 3 жыл бұрын
How would you bypass this switch if needed?
@aswitzer3895
@aswitzer3895 Жыл бұрын
Splice both wires together that would normally connect to the sensor. You risk damage if you actually lose oil, though. Probably only a good idea in an emergency until you can get a new switch.
@EricSilvaskiingmadman
@EricSilvaskiingmadman 3 жыл бұрын
yes, great job and start! the sip of beer during the moment of truth was key as well as the best practice that anytime doing something dangerous...start with a cold beer and remember to take your time and nurse that beer and relish in the moment of DIY success. don't do this at home unless you are great with tools...switzer clearly is a master of beer and all things electrical so don't expect the same miracles, unless you believe.
@edwardbaird9831
@edwardbaird9831 3 жыл бұрын
Lifesaver - thanks!
@rockwilliams457
@rockwilliams457 3 жыл бұрын
What size Generac do you have? I just got a 22kw, and am installing it. How long did you run it before you had this issue? Are you running synthetic oil 5-30? Thanks for this...
@aswitzer3895
@aswitzer3895 3 жыл бұрын
Motor oil is motor oil. Had it for 3 years prior to this issue.
@Mr39036ce
@Mr39036ce 3 жыл бұрын
You were the only guy to mention that negative pressure line!! Had one a shitty contractor installed.NEVER WORKED! Does now thanks to your video. Seems to work best closer to the fan intake.
@AjayMatai
@AjayMatai 3 жыл бұрын
Thanks for the video. This is exactly the issue I've been having. Where did you get the parts. Hayward's site doesn't shows the parts in stock.
@aswitzer3895
@aswitzer3895 3 жыл бұрын
Ebay.com
@zachpadilla9379
@zachpadilla9379 3 жыл бұрын
L Lll
@AndTodaysProjectIs
@AndTodaysProjectIs 3 жыл бұрын
Second time I needed to watch your video in a few weeks. Hard to find videos out there that show my problem. I was wondering if the control board defaults to "standby" after the power has been turned off for awhile. Tonight I replaced the pool pump and now the heater won't come on. I suspect it defaulted into standby mode so maybe you helped me once again.
@followthemoney911
@followthemoney911 3 жыл бұрын
Awesome video. Very helpful!
@stzsurge2250
@stzsurge2250 3 жыл бұрын
Yo it's me brendan your neighbor! :)
@aswitzer3895
@aswitzer3895 3 жыл бұрын
On Brewster Dr?
@stzsurge2250
@stzsurge2250 3 жыл бұрын
@@aswitzer3895 Marblehead Dr.
@houstonwarren2
@houstonwarren2 3 жыл бұрын
LMFAO. Thanks for posting. Our surface mount control board is trashed on the home we just bought so that has to be replaced but I also don't see the lights or temp so the board below must be half shot as well. The heater works fine for the hot tub though. This vid will get me through and back up to the heater's former glory I'm sure.
@frankpinheiro7531
@frankpinheiro7531 3 жыл бұрын
Thanks Adam for keeping it simple and informative GOOD JOB
@wlred
@wlred 3 жыл бұрын
Hi Adam. Thanks for the video. Just wondering why would you only want the humidifier to turn on if the heater is on and not just the fan? Shouldn't the humidifier keep running until it meets the humidity set point regardless of heat on? Thanks in advance.
@kkuldip123
@kkuldip123 3 жыл бұрын
Thanks for the excellent video. I have made sure that connections are correct. Water flows only when heater turns on and turns off when the heater turns off. However, the humidity is not increasing even when the humidistat is set to maximum. Any ideas as to what I can check? Thanks for your feedback.
@rkramer5629
@rkramer5629 3 жыл бұрын
Appreciate the confirmation on which terminals I needed but if someone slapped wires and hoses all over my system like that then they wouldn’t be getting paid... a few extra minutes and a little extra effort could have all that looking real nice.
@albundybudbundy3714
@albundybudbundy3714 3 жыл бұрын
Been a week struggling on wiring , so confusing , I got Honeywell HE360
@kkuldip123
@kkuldip123 3 жыл бұрын
Wiring for HE360 is different than on HE240
@sativa2050
@sativa2050 Жыл бұрын
call a professional if you dont understand the wiring. pretty basic stuff. it will cost you way more if they have to fix your mistakes instead of just having them install it
@stzsurge2250
@stzsurge2250 3 жыл бұрын
Hello
@tzerz_3957
@tzerz_3957 4 жыл бұрын
Hi Uncle Adam.
@loupopadich1364
@loupopadich1364 4 жыл бұрын
Thanks you are only one who explained in very short video everything.
@debbrownkatz6965
@debbrownkatz6965 4 жыл бұрын
My hubby followed your instructions and the solenoid started smoking , stunk up our whole house and ruined our humidifier. You need to have a transformer on the furnace!
@rkramer5629
@rkramer5629 3 жыл бұрын
“If” “Similar” Always good to double check. And a volt meter is any DIYers best friend... 😉
@nukestrom5719
@nukestrom5719 3 жыл бұрын
You want to make sure it is 24 V not 110V. It is always good to test with a multimeter the supply voltage
@SmokinLoken
@SmokinLoken 2 жыл бұрын
Agree with the other people who have commented. My furnace has a HUM terminal but I checked it with my multimeter first and it’s 120V, not 24V.
@sativa2050
@sativa2050 Жыл бұрын
this is why you have a professional install things when you obviously have no idea what youre doing. it will cost you way more when we show up to fix your mistakes
@foxgun100
@foxgun100 8 ай бұрын
Try reading instructions
@krdommert
@krdommert 5 жыл бұрын
Though I understand frustration if you cover is falling off I would not mount it with screws like you have here because the access door for the spare tire lowering rod must go through the small 2 1/2 square door on the right side. of the hitch. It is not advisable to make the access hard to get at. You can replace the lock springs and the turn locks to improve the hold. When lowering a tire : [Note insert the "flat" end on the rod first. GMs instructions could use improvement]
@KASSLERSCLACKE
@KASSLERSCLACKE 5 жыл бұрын
you ar super
@rolandohernandez5753
@rolandohernandez5753 5 жыл бұрын
Help! I am having trouble with the pressure switch tube...how do I get the rubber grommet into a 3/4" hole that the instructions tells me to drill? The elbow connector does not even fit in a 3/4" hole...what am I doing wrong?
@chucksiebenthal1654
@chucksiebenthal1654 5 жыл бұрын
Totally junk product from honeywell. They sell this product knowing that the solenoid will fail within a few months or years. I talked with service rep at Honeywell and she immediately knew which replacement part I needed and told me that the replacement part was not in stock and had no idea when replacement part would be available,.
@Jetfuture737
@Jetfuture737 3 жыл бұрын
Our solenoid is still going strong after 7 1/2 years. We have a whole-house conditioning water filter, so I don't know if that has helped extend its life. But I will say that I just replaced the circuit board on the humidifier.
@sativa2050
@sativa2050 Жыл бұрын
you couldnt be more wrong Chuck
@nonyabiz8064
@nonyabiz8064 5 жыл бұрын
Thank you for this video! It really helped me finish install. The instructions are not very good and your video answered all my questions! Bless you Sir!
@Amirnake
@Amirnake 5 жыл бұрын
What if the only place it can be installed is about 6-10 degrees tilted. So the humidifier would be level side to side but kind of leaning back a little to look at a tall building kind of gesture? Thanks for your video
@aswitzer3895
@aswitzer3895 5 жыл бұрын
That installation is perfectly acceptable. The membrane through which the water flows will still work effectively due to the power of surface tension!
@aihome242
@aihome242 5 жыл бұрын
Can you give me the part number for that cover please? I cannot seem to find it anywhere. Dealer wants $300, does not make sense.
@pgrgarcia5280
@pgrgarcia5280 5 жыл бұрын
Keystone Collision Rear Tow Hook Cover No Reviews Part # GM1129106 $26.99 Exact Fit for your 2007 Chevrolet Tahoe LTZ Advance Auto Parts
@mra8794
@mra8794 5 жыл бұрын
10364708
@emadmazhari1538
@emadmazhari1538 6 жыл бұрын
Thanks for the video. It was very helpful. I also trying to get the power from the furnace instead of using the transformer that comes with humidifier. The board of furnace has "HUM 24V" but it doesn't have "C" terminal. Instead it has "COM 24V" terminal. I think I should connect the two wires coming from humidistat to "HUM 24V" and "COM 24V". Am I correct? I have attached the picture of the board and specified the terminals. drive.google.com/open?id=1LZin_fVq942c6tswYXFhNvbeh7y4uUkj
@SmokinLoken
@SmokinLoken 2 жыл бұрын
Yes you are correct. He says C is for constant 24v in the video but he misspoke. C is for common.