Ant infestation tripping the RCD
13:13
Пікірлер
@stargazer-cb
@stargazer-cb Күн бұрын
Thanks for posting this information, it greatly assisted in diagnosing and replacing a faulty motorized control!
@TheLife0025
@TheLife0025 Ай бұрын
Hello. How can we connect boiler to wiring centre if it is on a distance.?
@ZoeSham-x5n
@ZoeSham-x5n Ай бұрын
Hi my plumber ran away.....i want to connect a Programmable thermostat to a junction box with a motorosed valve already in. How do i do it? Thanks fpr any help.
@Nuttylaughs
@Nuttylaughs 2 ай бұрын
Hi. Where do you connect up the 230v aqua stat on hw cylinder
@George-vl4lm
@George-vl4lm 2 ай бұрын
What an absolute mess of wiring and set up. Hardly anything labelled up or cable tied. At this level things should be trunked and runs should be super neat and tidy. It's difficult to see what you've done and what previous installers have done but that is a shocking mess. It seems every installer has just been in and added to a legacy set up to create that manifests in a horrendous mess of a set up. Unbelievable people pay professionals for this.
@bjoernbeck2260
@bjoernbeck2260 Ай бұрын
Sorry mate, I disagree. Most of the time, it's not the installer's fault. Cleaning up a mess like this will take hours. A lot of clients aren't willing to pay the money to clean this up.
@BenAllen-c6g
@BenAllen-c6g 2 ай бұрын
Hey guys, where about are you based it seems you really know a lot about this system and ours has just stopped working at the worst time of the year sad😮
@syl764
@syl764 2 ай бұрын
If you couldn't find a dedicated cable, but did have a cable nearby that's already in use for something else like a camera, you can always add a switch and route your WAN over a (third party gateway) VLAN, then loop it out of a LAN port on the UDM back into a WAN port. .Useful for putting a modem distant to the UDM. Don't keep that crap £100/month 3GB connection as a backup either, get something cheap on 4/5G with a Teltonika TRB device and an external antenna. I did the VLAN trick with mine to put the PoE powered TRB140 4G gateway up in a treehouse.
@tcntad87
@tcntad87 2 ай бұрын
10:45 I would do the same:P
@MaximusDementus
@MaximusDementus 2 ай бұрын
yuck, what about the cable management in the rack? that's a shame ;-)
@SeanyyBoy_
@SeanyyBoy_ 2 ай бұрын
im training and ive never been taught about max Zs for type C and D being unnatainable due to Ze figure!
@DOOM11777
@DOOM11777 3 ай бұрын
Lol only 3mbs for 10 yrs
@chimpo131
@chimpo131 3 ай бұрын
@@DOOM11777 starlink time
@darcsentor
@darcsentor 3 ай бұрын
That was nice clean work, interesting set up. On the UDM pro you can also use port 8 for ethernet-based internet connection. There is an option in the UI to enable it. No need to buy an adapter for the SPF+ port.
@HeritageElectrical
@HeritageElectrical 3 ай бұрын
Great advice @darcsentor
@PardoeElectrical
@PardoeElectrical 4 ай бұрын
Another case of you pay peanuts and you get monkeys
@PaulusSidabalok
@PaulusSidabalok 5 ай бұрын
Hi. I'm planning to install 3 cameras with NVR. Some sources said it's cheaper and better to have 'Acusense cameras + basic NVR' rather than 'basic ip cameras + Acusense NVR'. In my case, I only want to record based on the triggered event such as human or car. Not full recording 24/7. Is it possible with Acusense cameras + basic NVR? Are there settings to let the NVR record based on the event notif by camera, not by the NVR interpretation?
@Dog-whisperer7494
@Dog-whisperer7494 6 ай бұрын
Hats off to you sir for getting that mess sorted out and made safe. Well done 👏. I think I would have walked away from that one. That looked like a right pig off a job.
@HeritageElectrical
@HeritageElectrical 3 ай бұрын
Thanks 👍
@philipoakley5498
@philipoakley5498 6 ай бұрын
Worth pinning a link to the 'pdf' document mentioned as the first comment. It's not immediately obvious (given the link shortening) which link is the one you meant. Thanks for the video.
@HeritageElectrical
@HeritageElectrical 6 ай бұрын
Hi Phil. I have moved it before the start of the description now, and labeled it so it's a little clearer. Thanks for your support Cheers Heritage electrical
@MiloDavis93
@MiloDavis93 6 ай бұрын
90% sure the problem will have started when the smart meter was installed, most meter workers are not given full electrician training so can't legally go into RCD isolators or consumer units. Those RCD isolators can be a pain when they have clamp type connections, always coming loose when disturbed, that's why they need to be clipped in place before changing the meter 😬
@dohhomer9
@dohhomer9 6 ай бұрын
A very interesting video. I love my Heatmiser system, fitted it many years ago, over 12 years maybe. Our house is open-plan on the ground floor, using a wet under floor heating (UFH), with 5 or so loops, laid in aluminium spreader plates under oak veneer engineered flooring, it is just one zone. About six years ago I added a conservatory/utility room with wet UFH, laid under screed with a natural stone tiling on top, this is a second zone. Upstairs is a third zone with ordinary radiators. The hot water is a fourth zone. We are both retired and spend a lot of time at home, especially in the winter. Using the app I change the programming daily as we go into and emerge from winter. Each year I come up with a few tweaks that I try out to refine the process, the app is simple enough that this can be done quickly. We live in the SE and thankfully our winters have been mild for the most part, we spend the winter days in relative comfort in the conservatory. I believe I understand my system well as I have fitted it and learnt about it over the years. I would hate to be plonked down in front of a strange, complex system, as you were and told to fix it before the end of the day, great work.
@CrazySparkie63
@CrazySparkie63 6 ай бұрын
No glands or grommets on switch-fuse, conductors not identified by sleeving (or tape) and black been used for neutral, all ring alarm bells, I wonder what else you will find ?
@GilbertP57
@GilbertP57 7 ай бұрын
It took me ages to get my Heatmiser system properly, although in the end it was a lot to do with the manifold recycle/by-pass valve having solder debris in it. Did you use Heatmiser HW timers for the hot water?
@HeritageElectrical
@HeritageElectrical 6 ай бұрын
Yes Heatmiser systems can be complete but glad you got it working in the end.
@yoya4766
@yoya4766 8 ай бұрын
Could you talk any slower?
@HeritageElectrical
@HeritageElectrical 6 ай бұрын
Thanks for your feedback. You can always change the feedback speed to speed it up if you're short on time.
@MarcusT86
@MarcusT86 8 ай бұрын
Wow this vid looks like what I need. Just as a rough and dirty estimate… how best to get power to a shed 1 metre from the house, then continue on to a future garden room 9 metres from the house? One cable popping up in the shed, then carrying on to the garden room? Just need sockets and lights in both, and two electric radiators in the garden room. Would 16mm2 cable do the trick?
@08001967
@08001967 9 ай бұрын
can you demonstrate how you would work out a payback period calculation for this work I think another content creator worked out around 17 years with battery and no PV do you think this is about right?
@loveofkemet
@loveofkemet 9 ай бұрын
I’m sorry, but surely even a customer can see this is an absolute s*** show.
@planetpeckham1
@planetpeckham1 9 ай бұрын
Nice install! What make of box did you use to house the controllers? I’m looking for a large box to do something a bit similar. Thanks!
@johnspallen3132
@johnspallen3132 11 ай бұрын
As an electrical engineer and heating engineer I have never seen worse good luck 👍 sir
@jonshell9817
@jonshell9817 11 ай бұрын
Hi, Im enjoying all your Lutron RA2 video's very informative. I have a quick question that you may be able to help me with. I have RA2 installed in my kitchen and I want to add my curtain track to the RA2 control, is this possible? I was looking at installing a Somfy Glydea electric curtain track and motor, is there a way to make this communicate with the RA2 system and controlled via pico switch and app? Look forward to hearing from you.
@James-en3oy
@James-en3oy 11 ай бұрын
Thats horrendous, did they turn up on a horse and cart 😂
@justinmiller9812
@justinmiller9812 11 ай бұрын
Thank you for the videos they are very informative, any chance you could share the details of the relay for connecting to the vr71?
@elizabethbrayford6837
@elizabethbrayford6837 Жыл бұрын
Been trying to connect the hub to the charger and this video was really useful. Thanks!
@davekayan857
@davekayan857 Жыл бұрын
Hi, It is very educational, and learned a lot. I have a small question. I have GIV-HY-5.0 G3 inverter and a Gem120CTM meter. But not able to commission it. Potal not seeing the meter. Use ports 9 and 10 on the meter and the meter port on the inverter is correct. (+ & - are correct on both ends of the cable.) there is output on this twisted cable. But the system not seeing the meter. The meter displays all data such as voltage, download power, current, frequency, and so on. Maybe I require an EM115 meter !!! thanks
@cvarsani2190
@cvarsani2190 Жыл бұрын
I thought that using the VR71 would negate the need for a 10 way wiring centre, seeing that you have a Heatmiser Wiring Centre also Please provide more details on the relay and the VR10 pip sensor you mentioned shows up as either a tank or solar sensor. im sure alot of householders are stumped as to how to get Vaillant wiring centre and UFH wiring centre to work and maximise modulation
@jeshadpalkhiwalla1785
@jeshadpalkhiwalla1785 7 ай бұрын
@@Anthony-dh3ty Hi, just a follow up question on this. For a home refurb project I have ufh setup on a single floor with 4 separate heating zones using all heatmeiser equipment - thermostats (neostat), neohub(Gen2), wiring centre (UH8-RF), actuators (on manifold). The boiler in place is Vailant ecotec plus 625. To achieve boiler modulation is only the VR71 needed in addition to the heatmeiser equipment I already have? Or do I need to replace the heatmeiser equipment with Vailant ones?
@HeritageElectrical
@HeritageElectrical 6 ай бұрын
Hi if you'd like to discuss your project with us we'd be more than happy to talk it through in more detail - It's a bit hard to answer specific questions without all the details so please feel free to get in touch with us heritageelectricalautomation.co.uk/
@umarhussain7751
@umarhussain7751 Жыл бұрын
Hi mate where does the white one go ? Thanks
@davidpaterson2309
@davidpaterson2309 11 ай бұрын
Same question. He says “I’m going to ignore the white”. Yeah, but what do you do with it?
@StevenFosdick
@StevenFosdick 3 ай бұрын
According to the wiring diagram it is a normally closed (n/c) contact so it is connected to one of the other wires by the switch, when the valve is closed, and not connected to anything when the valve is open. What is not clear from the diagram, possibly because it is a bit small to read, is whether the other wire it connects to is the orange or the grey. If you have one to hand you can test this out with a multi-meter (when it isn't connected to the mains).
@garylatto4191
@garylatto4191 Жыл бұрын
Look Forward to the follow up, great vid mate 👍
@HeritageElectrical
@HeritageElectrical Жыл бұрын
Hi Guys, thanks for your positive comments and watching our videos. Apologies, but there is no part 2 for this particular job. We had 1 day to get that sorted and think we were there over 15 hours with a 2 hour drive back afterwards. Everything you see is what we had time to film. Basically you saw that system working and 1 room loop proved. All we did after that was all the programming for the customer and proved the rest of the UFH loops. Cheers Paul
@polarbear7720
@polarbear7720 Жыл бұрын
Good content something different to board changes, hope their is a part 2 would like to see conclusion of this job.
@HeritageElectrical
@HeritageElectrical Жыл бұрын
Hi Guys, thanks for your positive comments and watching our videos. Apologies, but there is no part 2 for this particular job. We had 1 day to get that sorted and think we were there over 15 hours with a 2 hour drive back afterwards. Everything you see is what we had time to film. Basically you saw that system working and 1 room loop proved. All we did after that was all the programming for the customer and proved the rest of the UFH loops. Cheers Paul
@polarbear7720
@polarbear7720 Жыл бұрын
Thanks for replying , a lot to get through in one very long day.@@HeritageElectrical
@mattlevesque5927
@mattlevesque5927 Жыл бұрын
Feel sorry for the guy that has to service that manifold inside that little cabinet
@darrenbrock5286
@darrenbrock5286 Жыл бұрын
Thanks for the help pal
@Issomethinggoingon
@Issomethinggoingon Жыл бұрын
Hi you said there it’s not possible to extend the ct cable length, is it not possible with Belen ? Is the only option the Dora things, they are soo expensive 😔
@security-pb4ee
@security-pb4ee Жыл бұрын
Many thanks for more deital and reviews these days. There are many options for a mix system. uhf, not sure which one is the best 1) honeywell 2) Dryton wiser 3) salus smart home 4) Heatmiser
@security-pb4ee
@security-pb4ee Жыл бұрын
Thanks for your review I wish you slove the issue Which one is the best for mix system underfloor heating and radiators 1) honeywell 2) Dryton wiser 3) salus smart home 4) Heatmiser
@skengy786
@skengy786 Жыл бұрын
My underfloor heating doesn’t go above 20 degrees what could be the problem ?
@TheSpikegreenwood
@TheSpikegreenwood Ай бұрын
@@skengy786 have you tried turning it off and on again?
@bhataamjad4074
@bhataamjad4074 Жыл бұрын
😂😂 work or hé someone make with this job
@Webbster77
@Webbster77 Жыл бұрын
Some joint that is!!!! 🤷🏻‍♂️🤦‍♂️
@markashworth79
@markashworth79 Жыл бұрын
That installation 😵 Rough as, glad they got a proper spark in to sort this. Great content, keep up the good work. 👍🏻
@HeritageElectrical
@HeritageElectrical Жыл бұрын
Cheers mate
@billsbasementworkshop1902
@billsbasementworkshop1902 Жыл бұрын
Hi, Interesting video. Just subed you. What reading was you getting at the sockets for the R1+R2? Would this be more than r1+r2/4? I got some high readings from sockets in the past, but useing some switch cleaner on the tester plug brought the reapinds down. I put this down to the contacts being dirty.
@HeritageElectrical
@HeritageElectrical Жыл бұрын
Hi Bill, thanks for watching. The R1+R2 readings passed when the socket plates were removed and cables jointed. The issue which we see a lot, as we test 100% of socket outlets, is a big difference between each side of the socket plate. In this case there were readings of >2000 on one plate and variations of 0.30 - 1.60 ohms difference between each side of some other socket plates. As the sockets were cheap, had been in 10 years and such a poor job had been done of connections, we changed the plates. In most situations we wouldn't bother trying to repair socket plates anyway, as they are not expensive to buy. We see them like brake pads on a car, they get a lot of wear and tear and at some point they will fail and need replacing, so we may as well do it if the readings aren't looking good. We always give the customer the options first, and they are always happier to go with the higher standard of work we recommend. Cheers Paul
@dustinzahursky6557
@dustinzahursky6557 Жыл бұрын
Will this control unit work with other branded sauna heaters like Harvia?
@mariuscioban5683
@mariuscioban5683 Жыл бұрын
Just notice, uh8 wiring box all deep switches for testing are on, that's the problem
@HeritageElectrical
@HeritageElectrical Жыл бұрын
Hi Marius. Well spotted, but that was not the issue. We tested the circuits with dip switches in both positions and all remained on, that was the positions the plumber left everything in. We just left them in that position as it made no difference. There is more content of this installation we have not had time to publish yet showing the back of the circuit board blown to bits! Coming soon! Cheers Paul
@livinglifeasa16handicapfor27
@livinglifeasa16handicapfor27 Жыл бұрын
I didnt add the door sensor. And now it comes up door open. Is there any way to get it to work without that door sensor installed?
@anya637
@anya637 Жыл бұрын
Promo-SM ✅
@deanmais886
@deanmais886 Жыл бұрын
They are flow meters on the top which measures flow rate per minute not bar pressure 🤦‍♂️🤦‍♂️