এইটা দিয়ে সার্ভো এবং VFD দুইটাই download করা যাবে
@therealtimeautomationandio7567 ай бұрын
Yes
@techideas68768 ай бұрын
Link pls.old link not working
@abdullahshahel69098 ай бұрын
aida ki video vai...kisui bojajai na...
@therealtimeautomationandio7567 ай бұрын
Node red communication with logo plc
@JohnTaylor-n9t9 ай бұрын
Great video how do you load a saved parameter list to a new drive. I.e reconnect to a new drive to load the file to. I mean a new connection
@therealtimeautomationandio7569 ай бұрын
Use RS485 cable
@JohnTaylor-n9t9 ай бұрын
@therealtimeautomationandio756 I got it mate. The uploads I was given had not been taken correctly so it was just a project file with the drive name. I have redone them with the correct project and variable data.
@wildesapegado245611 ай бұрын
Olá mestre estou com um altivar 340 qual porta eternet eu conecto o cabo eternet para essa configuração
@beckenbauer1974 Жыл бұрын
i have 2 modbus client one is read and one is write. it only work one at a time. if there is one running another one will be in error despite i have different address, please advice
@makotokarlsefni890610 ай бұрын
Use opposite clocks for each block, one clock normally open and another clock normally closed
@ShikhaMondal-q3v Жыл бұрын
😮😮😮😮
@ShikhaMondal-q3v Жыл бұрын
😮😮😮😮
@RAJESHMANDAL-lj3gc Жыл бұрын
good one
@avisautomation3235 Жыл бұрын
can you share link download software???????
@DHAKER9616 Жыл бұрын
which mode put drive when backup upload and download please replay
@JohnTaylor-n9t9 ай бұрын
Take the software offline and disconnect. The drive should be ready
@vladgaro7 ай бұрын
@@JohnTaylor-n9t when we want to download/upload the parameters of the drive it must be connected strictly to 24 V or it may be connected to 400 V?
@farhatahmed6332 Жыл бұрын
Thank you it's working 🥰
@therealtimeautomationandio756 Жыл бұрын
you welcome
@madhavrabari4756 Жыл бұрын
Sir TMT 162 ko sensor 2 skip kese kare (display F 041) nikalna he
@MjSportFishingTechnique Жыл бұрын
Tnks
@haipham-pm4ls Жыл бұрын
can you share link download software
@casta_99_45 Жыл бұрын
Link softwer?
@therealtimeautomationandio756 Жыл бұрын
The software is now free.
@adnansheikmytheen75492 жыл бұрын
really genious
@khafidilmi80702 жыл бұрын
hello brother i cant use modbus serial to option board somove can u help me for my problem?? can i have easy scanning IO VSD320 idont have driver modbus serial for somove
@therealtimeautomationandio7562 жыл бұрын
you need to setup the DTM file of VSD320. then you scan.
@therealtimeautomationandio7562 жыл бұрын
Here, MODBUS serial cable also possible
@ismailsinapli2 жыл бұрын
Спасибо
@nabilaputriofficial90812 жыл бұрын
i can't connect atv610 , why procces connect atv610 to somove ?
@therealtimeautomationandio7562 жыл бұрын
May be there is a problem with your IP address setting
@therealtimeautomationandio7562 жыл бұрын
Or may be there is a problem with your cable
@piyushsharma90842 жыл бұрын
What is the access password of prowirl 200?
@therealtimeautomationandio7562 жыл бұрын
0000
@sundharmohan34952 жыл бұрын
Hi here ur just downloading the program from vfs to pc, By clicking load from device, here u are not uploading the parameters, How to upload parameters to the vfd
@therealtimeautomationandio7562 жыл бұрын
Hello, "LOAD FROM DEVICE" means "UPLOAD"
@nelsongaymerortiz98132 жыл бұрын
Hi, when you put tcon_ip_v4 in connect of the module db client, this not function , the text stay in red (" mb configuration". "read CONNECT "), is this problem version of the PLC (v.22) S71200.????
@therealtimeautomationandio7562 жыл бұрын
Can you please elaborate
@darnellyork70192 жыл бұрын
promosm
@inesmartinez99642 жыл бұрын
Hello, I am following the video to establish Modbus TCP/IP communication between my PLC and a controller (which will be my server) using the MB_Client function in TIA. I need to read and write. However, I am not able to figure out why it is not working. Is there a specific way of assigning the ID for each block of MB_Client (why do you choose 10 and 20, is it random?)? When you define within the Instance DB the MB_Unit_ID to 1, should it always be like this? I am not able to figure out whether I am missing something. Thank you in advance!
@therealtimeautomationandio7562 жыл бұрын
Id for each block is randomly. And MB_Unit_ID will be 1,2,3..... 255 (depends on how many device you used).
@inesmartinez99642 жыл бұрын
Thank you very much for your response. And so if I want to Read and Write the same registers for one single server, therefore the MB_Unit_ID should be 1 in both cases. At the moment I am able to read and write separately, but, not when I use the 2 blocks for read/write at the same time. For some reason, both MB_Client blocks remain ´Busy´.
@makotokarlsefni890610 ай бұрын
@@inesmartinez9964 Have you tried using opposite clocks for each block, one clock normally open and another clock normally closed?
@chatingonlie74432 жыл бұрын
Only device name displaying
@therealtimeautomationandio7562 жыл бұрын
No, i have written the procedure also
@waqarhussain7292 жыл бұрын
What is the cable use to communicate somove into drive....?
@therealtimeautomationandio7562 жыл бұрын
I have used usb to rs485 then rs485 to rj45
@waqarhussain7292 жыл бұрын
@@therealtimeautomationandio756 is it working...?
@therealtimeautomationandio7562 жыл бұрын
Yes. I worked it with several project
@wildesapegado245611 ай бұрын
@@therealtimeautomationandio756 eu tenho esse cabo porém qual entrada do drive 340 eu conecto ele CN7?
@alearnerforsafety36923 жыл бұрын
Dear sir, I have SIMATIC S7-1200 and a Signal Generator Device and I use the NORM_X and SCALE-X functions in the TIA Portal program V 15 . The MIN value of NORM_X is 0.0 and the MAX is 27648.0 . It’s assumed that I use a RTD (PT100) with the Temperature Transmitter ranges ( -100 ˚C to 800 ˚C) and its output is 0-10 VDC. The output of NORM_X function is sent to two SCALE_X functions: one to scale the Ohms and the second to scale the temperature values. I depended on the RTD Temperature VS. Resistance Table to get the MIN and MAX values for these two scale functions. The first scale function which is for Ohms the MIN value is -100 ˚C whereas the MAX is 800 ˚C and the MIN value for the second scale function is 60.26 Ω and the MAX value is 375.7 Ω ( Because -100 ˚C is equal to 60.26 Ω and 800 ˚C is equal to 375.7 Ω in the reference table). But when I inject the following volt values in the Analog input of the PLC the output values of the Two SCALE_X functions are not as shown in the table?! Examples: 1- At 2.5 V the output of the first SCALE_X function is 124.4141 ˚C and the output of the second SCALE_X function is 138.91 Ω but in the Reference table when the Temperature is 124 ˚C the Ohms must be 147.58 Ω. 2- At 5 V the output of the first SCALE_X function is 349.93 ˚C and the output of the second SCALE_X function is 217.9 Ω but in the Reference table when the Temperature is 349 ˚C the Ohms must be 229.36 Ω. 3- At 7.5 V the output of the first SCALE_X function is 575.488 ˚C and the output of the second SCALE_X function is 297.0111 Ω but in the Reference table when the Temperature is 575 ˚C the Ohms must be 305.63 Ω. Why are the SCALE_X outputs not the same as what they must be as in the reference table?! And what must I do to make the outputs the same as what is shown in that table?! Thank you and I’m waiting for your reply.
@md.foridulislam50483 жыл бұрын
Voice quality is so poor
@rajeshmandal62673 жыл бұрын
use headphone. i think its good, not so much poor.
@rsrafi29853 жыл бұрын
Awesome
@therealtimeautomationandio7562 жыл бұрын
Thank you
@TARA-po8cn3 жыл бұрын
Nice Job
@therealtimeautomationandio7562 жыл бұрын
Thank yoi
@shortstory43443 жыл бұрын
Good Job
@therealtimeautomationandio7562 жыл бұрын
Thank you
@abdulkaderrashedjalaly3 жыл бұрын
Excellent video
@azizulhok7513 жыл бұрын
Nc
@জসিমখানওমর3 жыл бұрын
Nc
@mdbaharjalali62973 жыл бұрын
সুন্দর আলোচনা
@rahimbadsa7233 жыл бұрын
Nc
@lifetools4153 жыл бұрын
Nice
@mahinursultanasadiya17973 жыл бұрын
Wow
@sabikunnaherakhtersanjida15873 жыл бұрын
Great
@padmatvchannel37273 жыл бұрын
nice video
@raysatkhira3643 жыл бұрын
nice video
@crimegame73203 жыл бұрын
nice video
@kaziabdurrahman70363 жыл бұрын
nice video
@banglanews56933 жыл бұрын
Nice idea
@NEWAZSKITCHEN3 жыл бұрын
Nice
@Panda_01M3 жыл бұрын
Nox GameR
@shajonislam59243 жыл бұрын
Nice
@shajonislam47103 жыл бұрын
Nice
@ALHADISH7863 жыл бұрын
ভাই আপনার ফোন নাম্বারটা দেয়া যাবে ডিটেইলস আরো প্রচার প্রয়োজন ছিল।
@therealtimeautomationandio7563 жыл бұрын
email us at: [email protected]. There i will share you the phone number.