@yodal_
@yodal_ Жыл бұрын
Six flukes? At that point it isn't a fluke, it's a pattern!
@ronsampservice3066
@ronsampservice3066 Жыл бұрын
Great meters when they're working. I have the 8050, 8010 and two 8000s. Fluke was making some serious kit.
@tedivester4947
@tedivester4947 Жыл бұрын
Used a Fluke 8050 for years. It was our 'standard'. Really liked the Relative mode.
@johnjohn-ed9qt
@johnjohn-ed9qt Жыл бұрын
The 8000A is reasonably easy to work on. I have a stable full of them (used to have more, but I passed a few on a couple years ago) including several with the digital output connector (and a 1912A counter with the same). They still get some use as they are darn near bulletproof, as long as you don't need true RMS. For many, many years, my portable was an 8030A, which I finally shelved when the NiCads died again about 2002 or '03 and I had no desire to replace them. My favourite version is the mA-second option, intended for x-ray equip calibration. Mine came to me from the lab I worked in in the late '80s, where it was used for radiometry setting up medical laser systems.
@TheEmbeddedHobbyist
@TheEmbeddedHobbyist Жыл бұрын
I worked with these for years, lovely meter and I found it to be very reliable. Not seen one come up cheap enough to buy just for nostalgic reasons.
@ericwazhung
@ericwazhung Жыл бұрын
Score! I had one with a bad LCD which I can't recall if I actually did or just planned to replaced with LEDs via little more than some transistors... Can't quite remember the circuit I came up with off-hand, but as I recall it was to be wired directly to the LCD signals.
@uni-byte
@uni-byte Жыл бұрын
Nice haul!
@stephentrier5569
@stephentrier5569 Жыл бұрын
An 8010 and an 8012 have been my workhorse DMMs for ~25 years. The 8010 has a 10 A range while the 8012 has 2 and 20 ohm ranges. The 8010/8012/8050 series reportedly have a design defect in their display drivers that eventually kills the LCDs. The display goes black, like the bad ones you have. Aside from that they are great basic bench meters.
@p_mouse8676
@p_mouse8676 Жыл бұрын
I used to have the 8010 as well as 8050 combo. Pretty great meters, I regret selling them.
@robinbrowne5419
@robinbrowne5419 Жыл бұрын
A fun and interesting video 👍 There is something existential about an ancient Fluke meter measuring its own fuse, another one displaying random numbers, and the maverick with red leds :-)
@dwww720
@dwww720 Жыл бұрын
lol at the intro giggling and all ahahhaha
@zmix
@zmix Жыл бұрын
I bought 3 of these under similar circumstances - ages ago, all of them had bad displays or non functional segments in the displays.. it's not a 'fluke" I guess..!
@davidwalle5025
@davidwalle5025 Жыл бұрын
I have a stack of these meters work good except for the one with bad battery a few came from Sandia national labs.
@KeritechElectronics
@KeritechElectronics Жыл бұрын
And now I will watch this once again to see if it was not a Fluke. Oh... and use the forceps :)
@robinbrowne5419
@robinbrowne5419 Жыл бұрын
Ha ha.
@fmashockie
@fmashockie Жыл бұрын
Those snap action gang switches are horrible. They get dirty and can create all sorts of weird errors. When I saw that one note that said 'displaying random numbers' and saw the gang switches I was not surprised. I always give those a good clean before assuming its something else
@silverXnoise
@silverXnoise Жыл бұрын
I’ve got a few Tek function generators and DMMs from the same era, and those switches ruined them all. The ones that work are noisy as all hell.
@donsurlylyte
@donsurlylyte Жыл бұрын
there is some kind of kludge for replacing those screens, cant remember what it is
@davidparrot4669
@davidparrot4669 Жыл бұрын
merci pour vos videos c'est toujours un plaisir , j'ai un 8050A savez vous si il est encore possible d'acheter un ecran a cristaux liquide pour ces appareils ? , merci
@IMSAIGuy
@IMSAIGuy Жыл бұрын
I don't think so.
@spudhut2246
@spudhut2246 Жыл бұрын
bummer@@IMSAIGuy
@blugoose86
@blugoose86 Жыл бұрын
Where do you buy this stuff?
@IMSAIGuy
@IMSAIGuy Жыл бұрын
eBay
@samwillard5688
@samwillard5688 Жыл бұрын
😂I can only say that it must be nice!
@jordan390a
@jordan390a Жыл бұрын
Personally, I'd like to see you get back into the problems with that Wavetek Sweep generator.....
@garagehack9271
@garagehack9271 Жыл бұрын
Seems like you could use the camera gantry from.... John H or Mattias W. Can't remember which one did that
@fredmitchel1236
@fredmitchel1236 Жыл бұрын
I still use my 8050.... I bought it new in 1987
@fredmitchel1236
@fredmitchel1236 Жыл бұрын
And it has 4.5 digits...maybe it is 8051..
@franciscoferreira-eh1yu
@franciscoferreira-eh1yu Жыл бұрын
I kind of envy First world people. Here in Br trash ia sold as silver. A broke "out dated* Fluke equipament is sold as Gold. Six of they would cost my house. Lol
@inerlogic
@inerlogic Жыл бұрын
6 for $30? I'll buy a working one from you for $20 (plus shipping)
@IMSAIGuy
@IMSAIGuy Жыл бұрын
I handed them out to friends when we were out for lunch
#1658 This was not a Fluke, it was six (part 2 of 2)
15:28
IMSAI Guy
Рет қаралды 3,6 М.
#1655 Are 555 Clones Better?
12:29
IMSAI Guy
Рет қаралды 8 М.
WORKSHOP WEDNESDAY: Panzer II TURRET RING disassembly
16:30
The Australian Armour & Artillery Museum
Рет қаралды 3,6 М.
🔴 Fluke 289 Multimeter Review - Sponsored by Fluke & Pomona - No.1046
1:08:24
Defpom's Electronics Repair
Рет қаралды 28 М.
GR-78 Restoration - Part 1
14:27
Bruce Carter
Рет қаралды 1,2 М.
#1666 Old Electronic Parts from an Estate
7:50
IMSAI Guy
Рет қаралды 4,6 М.
#2113 Heathkit ETW-3800 Microprocessor Trainer (part 1 of 3)
13:44
Why Is MIT Making Robot Insects?
21:16
Veritasium
Рет қаралды 3,5 МЛН
EEVblog #544 - Fluke 5450A Resistance Calibrator Teardown
36:51
Getting started with an oscilloscope
23:13
learnelectronics
Рет қаралды 41 М.
EEVblog 1452 - Fluke PM3370B Combiscope REPAIR
28:34
EEVblog
Рет қаралды 65 М.