Your slang to say "t" of Momen"t" with a bottle opening sound. 😍
@PRANITGONDHALI Жыл бұрын
5:27 Live load is wrong as it has used cos 2 times .initially 350xcos =585 and again 585 x cos.please review
@haridassawant9996 ай бұрын
Very good explanation
@demnongtdu7317 Жыл бұрын
Good morning madam I watched your video and found you design a truss for roof angle of 30 degree ! My point is that what if the roof angle is 10 degree
@arumugamudalid53782 жыл бұрын
nice presentation
@rakeshstructure335 Жыл бұрын
Table 3 section properties m Ixx you take 72.5 why its taken. Why we can't take uper value 56? Please mam explain.
@omh26773 жыл бұрын
This is really helpful and thank you sooo much civil girl♥️
@ajj70383 жыл бұрын
When direction of wind is negative z direction, moving towards rafter... Why u tuk the slope of the roof as z-z axis
@mohitdahiya91159 ай бұрын
Hello Sister I am a Mechanical Student. I want to learn truss Design. How i can which book i can follow?
@vishnumehra15713 жыл бұрын
Can u suggest a book for me.. where i can find the whole procedure 🙏
@jonahlj05072 жыл бұрын
Where should I use these values in staad pro can u make video on that
@maliknasrullahkhankhan76362 жыл бұрын
madam live load and dead load vertical components will be 448x sinalpha and horizontal is 448xcosalpha
@Juss_ThaiBoyyYАй бұрын
@7:05 mins why Zdir. Y not taking the maximum value?
@Juss_ThaiBoyyYАй бұрын
Plz explain once miss
@hemrajrai8794 Жыл бұрын
How to join or fit this type of truss
@pradipchakraborty9973 жыл бұрын
Hey you had taken the value of €=(fy/250)^1/2 instead of €=(250/fy)^1/2 which one is correct please explain
@thecivilgirl70873 жыл бұрын
Its (250/fy)
@bharathlatha4503 жыл бұрын
8:32 from/how did u get w/m?
@saadsaiyyedofficial84134 жыл бұрын
Supppr mam keep it up
@ravikiran20873 жыл бұрын
all the procedures are very clear but......ur smile at 5:53 is not clear :-)
@sibhichelvane69184 жыл бұрын
👍🏻
@bharathlatha4503 жыл бұрын
9:40 where to see the table for semicompact?
@sunandarane6077 ай бұрын
Same question
@sarthakvora3543 жыл бұрын
If we are using circular section, then also do we have to use load directions in y-z direction as done for L section?
@civilpadinga14504 жыл бұрын
♥️♥️♥️
@civilpadinga14504 жыл бұрын
Good job 👍 5.53 cute😚
@kalyug53762 ай бұрын
Hi I need a help
@sunilsindagi5593 жыл бұрын
I want plan for 60 /100 she'd
@bharathlatha4503 жыл бұрын
7:46 how l=4.5??
@265d7 Жыл бұрын
4.5
@minlenhaokip5322 Жыл бұрын
What the hell are you talking about just calculate the spacing of rafter....