200 ft Crosslay, speed load, triple layer load using FDNY Spec or 1.88" hose. This technique should be used for the 2 1/2 Crosslay as well.
Пікірлер: 21
@WayneClemonsJr Жыл бұрын
Love the triple fold. Easy to load and even easier to deploy for those who may struggle with upper body strength.
@lordismo8 жыл бұрын
I wonder how much they clowned Martinez for rolling a gutter ball. I've done it many of times too.
@firehousewindowcleanersllc51607 жыл бұрын
lordismo I was there for this, the idea was to show a dirty, minimally edited video on how to load hose for rookies (and the rookies at heart). and yes, I've done that before too
@Nate-cw7of4 жыл бұрын
Must be a inside joke
@Somedude8192 жыл бұрын
I love how the whole comment section isn't about the load but about Martinez
@terryleimonis7 жыл бұрын
The gutter ball? lol id be buying ice cream if my phone wasn't on vibrate for this and got a phone call! lol!
@Basketballlegendsleague6 жыл бұрын
Rios is a god among men!!!!
@craigzale43456 жыл бұрын
If you take an old piece of 2 1/2 hose about 10 inch"s long (sew or melt the ends to stop fraying)and put it over the end of the pony where it attaches to the first 50 foot section of the lay it will protect the paint on the rig. We have been using a triple for many years with great success and a very fast clean pull off.
@WilliamSeibertwillis9238 жыл бұрын
Damnit Martinez... lmao
@danso56597 жыл бұрын
Dammit Martinez!!!!
@emt-lee22384 жыл бұрын
Can you show a video of how y’all deploy it
@amandahenry65107 жыл бұрын
May I use this video on facebook please?
@robzazueta88152 жыл бұрын
Martinez didn't understand the assignment.
@myriadcorp8 жыл бұрын
What a pain in the ass way to load hose.
@firehousewindowcleanersllc51607 жыл бұрын
myriadcorp -How do you do it?
@mitchellmcnally20084 жыл бұрын
Perhaps. It also deploys like a absolute legend and only pulls out 66 feet to make 200ft. charge that baby and your good to go. No spaghetti mess. No real hose tidying before charge
@hosedragger-204 Жыл бұрын
It may be "a pain in the ass way to load hose" but it's what my department uses. I had to pull one and bring it to the door for the investigation crew after they found that fire had escaped a chimney through a gap in the sheet metal sections it was made of and then spread upwards through the interior of the wall and into the attic of a home. I pulled it with ease and it charged without kinks or having to flake it despite me having NEVER previously deployed ANY kind of a crosslay before due to being brand new and having just begun my training.