2024 NFPA 70E Major Changes - Jim Phillips, P.E.

  Рет қаралды 8,456

Brainfiller Arc Flash Training

Brainfiller Arc Flash Training

Күн бұрын

Пікірлер: 23
@j81851
@j81851 8 ай бұрын
Jim, I deeply admire and enjoy your lectures and think you are a stable resource that does not bend to the wind of trends. I recommend you as the "Arc Flash Expert" in all my ESWP classes. You are a lighthouse in the storm of misinformation out there.
@Brainfiller
@Brainfiller 8 ай бұрын
Thank you for your kind words and support! Best Wishes!
@Roberto-cg2gr
@Roberto-cg2gr Ай бұрын
Engineering logic tells us that doors in the experiment that doors shall have sufficient lock or bolted for Engineering solution to safety. The part of the hinge clearly has sufficient strength. Require standard on how covers will be locked to sustain available short circuit arc flash. Also, there should be an Arc Flash rating on the metal sheet . If PPE has Arc Flash Rating. Metal Sheet used in panelboards and switchgears shall also have Arc Flash rating based on material used and thickness. Hope this will be in the next revision
@Roberto-cg2gr
@Roberto-cg2gr Ай бұрын
Can Philippines give a suggestion on the revision of NFPA70E
@JosephAugeri
@JosephAugeri 11 ай бұрын
Thank you
@plchacker
@plchacker Жыл бұрын
Is there any chance that there will be higher categories of PPE added since we have more capable PPE? I honestly expected this update for 2024.
@Brainfiller
@Brainfiller Жыл бұрын
Nothing that I have seen is on the radar screen regarding higher catagories for NFPA 70E. Many lean towards calculated incident energy.
@j81851
@j81851 8 ай бұрын
Why? Hierarchy of controls suggests Eliminate the hazard. Have we all not looked at Doughty and Neal in the 90's and IEEE/NFPA collaboration of the early 2000's? 5-12 calorie arc flash 140 db SPL consistently. You guys can wear all the 100 cal stuff you want. My students are trained to reduce or eliminate the hazard. Their leaders need to be trained that convenience and prevention of financial loss still does not justify the risk. LOOK AT THE controls pyramid.. PPE IS THE TIP OF THE SPEAR!! I do NOT care about improvements in PPE, PPE at best is marginal to keep you from being dead. Sound is sound. 141 DB SPL is around 2160 psi pressure to the body. Why are we so adamant to make it electrically safe when in doing so we expose people to huge electrical explosion risk glibly "oh the PPE has improved!!" Really? The Psychics of the arc flash is the same as it was 40 years ago when Ralph Lee published "Arc Flash the the other Electrical Hazard". Yeah I hear you all this is some old guy. Yeah following the rules is why I am still standing at 72. Think about it. Oh, and remember all the whiz bang relaying and fiber loops you do still reduce the hazard but 5-12 calories (rather low values) still generate the maximum OSHA allowable exposure. Again think about it.
@Brainfiller
@Brainfiller 8 ай бұрын
@@j81851 I was part of the steering committee of the final incarnation of the IEEE/NFPA collaboration and on the 70 Committee. There is quite a bit of inertia so veering from the existing categories in the near term is unlikely.
@Roberto-cg2gr
@Roberto-cg2gr Ай бұрын
Mabuhay Philippines
@Roberto-cg2gr
@Roberto-cg2gr 21 күн бұрын
Engineering logic tells us that the lock is not enough for the door. Should be calculated to sustain the fault
@bobcocampo
@bobcocampo Жыл бұрын
What are the arc flash ratings of metal enclosure covers of panelboards and switchgears
@Brainfiller
@Brainfiller Жыл бұрын
Metal enclosure covers, panelboards and switch gear do not have arc ratings like PPE. However, some equipment like switchgear can be designed based on standards such as C37. 20.7. This equipment, known as arc resistant, is designed to contain the energy during an arc flash if it is properly closed.
@bobcocampo
@bobcocampo Жыл бұрын
@@Brainfiller Right now it has no rating. However, if cover will have rating it will assure that the person in front of the switchgear. This may allow person in front of the switchgear just monitoring to be safe without a PPE. If PPE can have a test on Cal per m2 then enclosure covers should have this test too.
@Brainfiller
@Brainfiller Жыл бұрын
@@bobcocampo Equipment can go thought testing to be arc rated. This is not an arc rating. It is the ability of the equipment to contain the energy. PASS/FAIL not a specific arc rating like PPE. Two different things.
@educationpower1823
@educationpower1823 Жыл бұрын
At speed of light
@educationpower1823
@educationpower1823 Жыл бұрын
Also, I have discovered an alarming number of people who do not read the instructions from manufacturer on how to properly use a noncontact test instrument..for example the need to be properly grounded to avoid false readings etc. Thoughts of untrained people relying on this method?
@Brainfiller
@Brainfiller Жыл бұрын
It's like so many other things. Training is the key and without it, things can go terribly wrong.
@educationpower1823
@educationpower1823 Жыл бұрын
Jim. I teach that shock is tramua forced on the body..like car accident, baseball bat upside head. etc. Electri shock is electrical trauma forced on body at spoed of light..Robert from Omaha
@Brainfiller
@Brainfiller Жыл бұрын
Serious shock needs medical attention even if the person seems to be OK. Sometimes effects aren't noticed until sometime later.
@plchacker
@plchacker Жыл бұрын
130.12? Is there any way to change this word salad? I understand the intent, but it looks like a team of HR/Safety, Lawyers and ISO freaks wrote this. It could simply say, "Before any work is done to electrical equipment/conductors, care must be taken to insure all possible electrical sources have been put into an electrically safe condition." It is suppose to address the possibility of multiple sources or back feeding on a circuit that is being worked on. Every qualified worker would be well aware of this hazard and will take precautionary steps.
@Brainfiller
@Brainfiller Жыл бұрын
The best way to initiate a change is to submit Public Input (proposal) for the 2027 edition a NFPA.org. The closing date is June 4, 2024. Thanks for your comment.
@Roberto-cg2gr
@Roberto-cg2gr Ай бұрын
Engineering logic tells us that doors in the experiment that doors shall have sufficient lock or bolted for Engineering solution to safety. The part of the hinge clearly has sufficient strength. Require standard on how covers will be locked to sustain available short circuit arc flash. Also, there should be an Arc Flash rating on the metal sheet . If PPE has Arc Flash Rating. Metal Sheet used in panelboards and switchgears shall also have Arc Flash rating based on material used and thickness. Hope this will be in the next revision
Arc Flash Studies and Electric Utility Company Short Circuit Data
13:39
Brainfiller Arc Flash Training
Рет қаралды 10 М.
2018 NFPA 70E Changes - Jim Phillips, P.E.
1:05:39
Brainfiller Arc Flash Training
Рет қаралды 34 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 6 МЛН
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 19 МЛН
Миллионер | 3 - серия
36:09
Million Show
Рет қаралды 2,1 МЛН
Мама у нас строгая
00:20
VAVAN
Рет қаралды 11 МЛН
2024 NFPA 70E Major Changes
1:00:18
ELECTRICAL CONTRACTOR Magazine
Рет қаралды 661
EC&M Tech Talk Video - Changes to the 2024 NFPA 70E
25:50
2021 NFPA 70E Changes & Updates - Jim Phillips Free Class
1:00:06
Brainfiller Arc Flash Training
Рет қаралды 21 М.
VFDs & Harmonics
54:26
Efficiency Vermont for Trade Partners
Рет қаралды 12 М.
Changes to NFPA 70E 2024 edition
1:05:54
Ryan Jackson
Рет қаралды 9 М.
Electric Safety Presentation
38:17
Holy Cross Energy
Рет қаралды 167 М.
Kitchen islands and peninsulas in the 2023 National Electrical Code
17:14
Job Safety Analysis (JSA) - Safety Training
16:29
HSEBox
Рет қаралды 29 М.
Overcurrent, Overload, Short Circuit, and Ground Fault
6:54
Dave Gordon
Рет қаралды 923 М.
2024 NFPA 70E Simplified: A Condensed Crash Course for Safety Leaders
59:02
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 6 МЛН