Assalam o Alaikum Arsalan bhai masha Allah se aap bht acha kaam ker rhy hain, Allah aap k kaam mei mazeed barkat ata farmai, plz Nitrox ki SBU ki settings per 01 detail vdo bana dey.
@AGradeSolarKarachiАй бұрын
Walaquam Asslam - Video Buni Hui Hai - *Time of Use Mode SBU ki hei setting hai* is per check ☑ lega ker volt set ker dain ager tubular hai to aur lithium hai to percentage jitni use kerna chate hain sub menus mein setting ker ke save ker dain SBU operate ho Jaye Ga
@danishahmed4999Ай бұрын
❤❤
@successachiever7777Ай бұрын
Good work done. Is earthing is necessary in 3,6 and 8 kw projects ? And what's benefits of earthing ?
@AGradeSolarKarachiАй бұрын
Its Extra Safety for Users - Barish Mein Current Nehin Lege Ga - SPD Ager Lagayain to Earthing Compulsory Hai
@successachiever7777Ай бұрын
Brother kahan se current lagta he barish main solar penals, invertor ya battery se ?
@mansoorqazi3582Ай бұрын
Earthing provides life and equipment safety.its play main role in electrical system .
@abdurrahmanmuhammadi123Ай бұрын
Solax with dyness battary ka comobo banay ya solax with z box ka
@SalmanMuraad19Ай бұрын
Dyness is cheaper. Go for it.
@AGradeSolarKarachiАй бұрын
Z Box Mein BYD Ka BMS Not Confirm That it will synic through bms or not - U May Go With Dyness
@harisahmed9139Ай бұрын
Earthing Ki Total Cost ??
@AGradeSolarKarachiАй бұрын
03 - Earths = 120,000 - Green Wire Additional
@harisahmed9139Ай бұрын
@@AGradeSolarKarachi Total Cost Of Net Metering
@asimsamdani7238Ай бұрын
Nitrox 20kw-3P ( price please)
@AGradeSolarKarachiАй бұрын
400,000
@Huzaifa_xDАй бұрын
G bhai approve hogaya?
@AGradeSolarKarachiАй бұрын
Alhamdulillah
@bilalzahid5399Ай бұрын
LHR mn to koi check ni krny ata earthing na visit hota Earthing k bagair b meter lg jata
@AGradeSolarKarachiАй бұрын
Lahore - Lahore Ae
@SalmanMuraad19Ай бұрын
I want an estimate of 12 Kw PV Ongrid 10 Kw Nitrox based system with all K. Electric file processing, inspection, earthing, everything on double story construction with elevated structure (Pipe + Garder). You can quote without wiring as I can understand it varies from site to site. Kindly do state approx time for net metering file processing and solar system to becoming functional for K. Electric. Area: Sindhi Muslim. Sanctioned Load: 3 phase 5 Kw with 6 meters installed in the building. We live in a portion based building, where the roof and meters are in the name of builder. He has agreed to provide his cnic and signatures, if we want to install ongrid system. We want to transfer 3 out of 6 portions to the solar system.
@AGradeSolarKarachiАй бұрын
Plz WhattsApp 03433477786 - 10KW System Will Cost You Around 10 - 11 Lac OnGrid - U Should Have Santion Load At Least 8KW