3 PIR's Lighting Control - Wiring Diagram Part 2

  Рет қаралды 51,831

GSH Electrical

GSH Electrical

Күн бұрын

Matt looks at the basic wiring diagram for a circuit controlled by 3 Passive infrared sensor (PIR). He looks at the working principles for controlling a circuit by a remote PIR to control things such as lights. In part one Matt looks at the wiring connections in both the PIR's and the use of a one way switch to override the PIR''s.
This On Site with Matt video is to help with his delivery of distant learning to his level 3 learners.
🔵 On Site with Matt PIR Controlling a Contactor. Wiring Diagram to Help with Distant Learning Part 3 • PIR Controlling a Cont...
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
▶️ TikTok vm.tiktok.com/...
#GSHElectrical #Electricaltrainingvideos #wiringdiagram #lighting

Пікірлер: 55
@jmohammad3762
@jmohammad3762 4 жыл бұрын
Another great video from GSH Electrical Tutors. Love with way these guys make the connections looks simple. Perfect for a novice like myself. Top Team 👍👍👍
@Dibbo1979
@Dibbo1979 4 жыл бұрын
That felt tip noise went right through me😂. Great video mate
@tigergkw2498
@tigergkw2498 4 жыл бұрын
In the end I decided to wire my 3 PIR's and 3 security lights exactly the way you illustrated. And they work a treat :-) . Of course, they'd never pass any sort of inspection, but they'll do me for now. Thanks very much for your help :-)
@brianoceallaigh8714
@brianoceallaigh8714 4 жыл бұрын
Good one Matt, My profile picture is what your video is about, been wiring quite a lot of lighting circuits of late especaily in factories where no light switches are used... Enjoy your videos Matt, top class...
@kabandajamir9844
@kabandajamir9844 Жыл бұрын
The world's best teacher thanks
@tigergkw2498
@tigergkw2498 4 жыл бұрын
Great.....just what I was looking for to wire 3 PIR's and associated lighting round a detached garage after a recent attempted break-in !! Thanks for taking the time to help us non electricians out :-) . Now.....how to get that wiring done in practical terms.....here we go.... !! ;-)
@earlyyearslearningisfun
@earlyyearslearningisfun 4 жыл бұрын
Thanks Matt 👍
@zahirnaseem7030
@zahirnaseem7030 Жыл бұрын
Great tutorial! Thanks for the upload
@GSHElectrical
@GSHElectrical Жыл бұрын
👍🏻
@nickbuckle646
@nickbuckle646 4 жыл бұрын
My prefered way of achieving this with outside lights is to wire a seperate 3 core to pick up the PIRs and then a seperate cable, either 2 or 3 core to the lights. Run the cables back to the dis board and make a wago joint in a labelled adaptable box. You can go a step further and run individual cables to PIRs which can allow easier fault finding when they eventually go wrong, down side is extra cost of cable. With corridor lights you can run common 3core through all lights and PIRs, the only problem can be if you need emergency fittings that are to be tested with the remaining lights staying on, in which case you need an extra core or self test fittings.
@CH-en4er
@CH-en4er 2 ай бұрын
great video thank you
@GSHElectrical
@GSHElectrical 2 ай бұрын
Thanks
@alfonsputzeys9228
@alfonsputzeys9228 Жыл бұрын
I never tought of this solution. My schematic relied on a 2pole 2 way switch to switch between power from the pir and mains power. But the use case is similar. 2 to 3 pir that control 4 led flood lights. To light up the area around the house and the gras area ontop
@eddie_pegasus_electrical
@eddie_pegasus_electrical 4 жыл бұрын
Excellent vid for learners
@pjcartlidge
@pjcartlidge 3 жыл бұрын
Fantastic, thanks 👍
@phough5247
@phough5247 2 жыл бұрын
Hi. So I've wire one 2 pir's, then connected two led 20w floodlights to the switch live, neutral, earth. It works but when the leds are in standby, half of the little leds are slightly lit up. Is this normal? When you fully unplug power the lights completely go out
@ravigrover11
@ravigrover11 3 жыл бұрын
Hi what happens if 2 motion sensor are activated at same time in this circuit.will it damage the load. I want to attach 3 motion sensor to a bell to be used as burglar alarm. One motion sensor infront of each door which connect to a bell. Pls suggest
@eksine
@eksine Жыл бұрын
will not damage, they are all doing the same thing: connecting load (light) to the HOT, the motion sensor is simply acting as a relay triggered by infrared detection
@ianweatherley2467
@ianweatherley2467 5 ай бұрын
Can the Lamps share the same neutral circuit as the PIR's?
@gczz
@gczz Жыл бұрын
I have a very specific case going on here that I'm not sure how to handle. I've installed Led tape lights underneath both sides of my bed. I've installed one PIR sensor on each side, so the idea is that only one side would light up at night when detecting presence on respective side. Because I have a lack of wall outlets, I'm trying to use only one power supply, so basically each led light and sensor are in parallel with the power supply. The issue is, this PIR sensor closes the circuit up when it's connected to power, before actually opening it and waiting for "presence", so when one side detects presence, it lights up, but when it powers down, the other side lights up immediately, as if the sensor had been connected to power, and it keeps doing this alternation a few times before it switches off completely. I'm thinking two diodes might do the trick, but I'm not sure.
@Yahatacooky
@Yahatacooky 2 жыл бұрын
Great video but what if the PIR has an additional two terms marked D1 & D2?
@matthewo6077
@matthewo6077 Жыл бұрын
Can you have an overwrite switch on each PIR so you can tern the one off you don't want .
@BerHarSenSam
@BerHarSenSam 2 жыл бұрын
Great. Thank you. It looks like having more than one one-way override switch would work as well?
@motoxali13
@motoxali13 2 жыл бұрын
Thanks for the video. Do you know if this will work with any two PIRs?
@GSHElectrical
@GSHElectrical 2 жыл бұрын
Yep
@tigergkw2498
@tigergkw2498 4 жыл бұрын
Am I right in saying that if a potential burglar decided to rip one PIR out from that set-up, then non of the others could still act independently ?? I want to wire mine up so that if one PIR was ripped out, then the other two could still work independently and be more of a deterrent. A diagram of how to wire a circuit the way I would like to do it would be very helpful, I can see me having wires here, there, and every bloody where !! 🤔😳
@Hussking84
@Hussking84 Жыл бұрын
Question at 1:48 you are drawing a line what is the cable linking all PIR ? Is that the black on a 3 core twin and earth cable or a separate cable?? Can you identify that plz Cheers
@jackinfo121
@jackinfo121 4 жыл бұрын
hi. just wonder why the need of override switch? thanks
@GSHElectrical
@GSHElectrical 4 жыл бұрын
On Site with Matt PIR Contactor Controlled Lighting Circuit with 3 Position Switch. How do they Work kzbin.info/www/bejne/bGnVpIqdh9CHapo
@MrEndzo
@MrEndzo 2 жыл бұрын
What if I wanted to have the override to be able to turn the pir off? Edit: found the answer later in the next part
@mattyourell609
@mattyourell609 3 жыл бұрын
Can you do this with lights with integrated PIR's or do you have to have separate PIRS to achieve this?
@Paulryan84
@Paulryan84 4 жыл бұрын
Hi. Would you take the neutral from the PIR’s to the light or would the light need to go back to the board ? Cheers
@bigbud1978
@bigbud1978 4 жыл бұрын
That’s what I was also wondering?
@paultipton743
@paultipton743 4 жыл бұрын
I would take the neutral from the nearest pir as the neutrals are linked through anyway
@christianjohnson7036
@christianjohnson7036 4 жыл бұрын
Gteat video thanks! Quick question - am I right in thinking that if one of the PIR's were activated and turned on the lights, you couldn't then use the one way switch to then turn the light off could you? I'm guessing youd have to wait until the time set on the PIR had expired.
@javandermerwe
@javandermerwe 4 жыл бұрын
Correct
@eksine
@eksine Жыл бұрын
@@javandermerwe you are both wrong, the bypass switch is intended to turn the lights on, an over ride, however he drew the diagram wrong anyways because he drew it between the wrong 2 PIR sensors, it needs to be on the same location as where the load is.
@brianhewitt8618
@brianhewitt8618 Жыл бұрын
👍
@Ukman-england
@Ukman-england 2 жыл бұрын
Is it live and earth on the switch
@ThomasLouttit
@ThomasLouttit 2 жыл бұрын
Can someone please tell me how the Load ratings of these PIR motion sensor switches?
@RanjeetJagtap007
@RanjeetJagtap007 2 жыл бұрын
How to connect 3 PIR sensor with one siren?
@baldyslapnut.
@baldyslapnut. 3 жыл бұрын
As drawn your PIRs look like they're in series. To get them in parallel you'd need a JB with a second SL feed from a 2G switch, then 3C+E from that JB to each PIR wouldn't you?
@darrenowen3338
@darrenowen3338 3 жыл бұрын
To be in series, the output (switched live) from one would have to be the feed (live) for the next one, and so on. You'd either have to activate all three to get your lights on, or the inactivated one(s) would be redundant.
@baldyslapnut.
@baldyslapnut. 3 жыл бұрын
@@darrenowen3338 yeah, see it now. Must have been half asleep last time I watched😴. Thanks 👍
@nanageneral756
@nanageneral756 2 жыл бұрын
Can I use the same method to wire 4 microwave sensors to operate one bulb?
@MonaichFother
@MonaichFother Жыл бұрын
Why not, jinthis example he just chose to show three.
@MK-wf1eg
@MK-wf1eg 4 жыл бұрын
I'm guessing we use 3 core and earth from supply?
@loosecannon5813
@loosecannon5813 4 жыл бұрын
Yes, I run interconnected smoke alarms like that as well. Remember to terminate the switched live properly within the consumer unit.
@jamesgledhill9667
@jamesgledhill9667 4 жыл бұрын
Only need twin and earth from supply. Then three core between pir. Then twin and earth to light
@loosecannon5813
@loosecannon5813 4 жыл бұрын
When I run the 3 core back to the consumer unit, I've then got a switch line which can be easily 500v insulation resistance test, also I can add and have added additional interconnected smoke alarms from the board.
@jamesgledhill9667
@jamesgledhill9667 4 жыл бұрын
@@loosecannon5813 what's smoke alarms got to do with it? You only need switch wire from pir to light.
@eksine
@eksine Жыл бұрын
Your bypass switch is not drawn correctly, if those 2 PIR are off on the switched side your lights will not turn on because the lights are wired on the switched side between the 2nd and 3rd PIR, you have drawn the bypass switch between the 1st and 2nd PIR which is not the same location as the load (lights) , please take a look at your diagram again and look at where your load is in relation to the PIR's
@cecilandrews7479
@cecilandrews7479 8 ай бұрын
Your drawings messed up, you don't have a neutral line going to the lights. Somebody following this he'll be saying Hell my lights don't work
@persian_warrior1
@persian_warrior1 2 ай бұрын
this is not for someone who doesn't have any clue about electrical. thanks for the video. now, I simply know how few pir could work and control the lights in one go at different locations. ❤❤❤
@gczz
@gczz Жыл бұрын
I have a very specific case going on here that I'm not sure how to handle. I've installed Led tape lights underneath both sides of my bed. I've installed one PIR sensor on each side, so the idea is that only one side would light up at night when detecting presence on respective side. Because I have a lack of wall outlets, I'm trying to use only one power supply, so basically each led light and sensor are in parallel with the power supply. The issue is, this PIR sensor closes the circuit up when it's connected to power, before actually opening it and waiting for "presence", so when one side detects presence, it lights up, but when it powers down, the other side lights up immediately, as if the sensor had been connected to power, and it keeps doing this alternation a few times before it switches off completely. I'm thinking two diodes might do the trick, but I'm not sure.
PIR Controlling a Contactor - Wiring Diagram Part 3
6:04
GSH Electrical
Рет қаралды 18 М.
PIR Lighting Control - Wiring Diagram Part 1
7:01
GSH Electrical
Рет қаралды 146 М.
How do Cats Eat Watermelon? 🍉
00:21
One More
Рет қаралды 12 МЛН
哈哈大家为了进去也是想尽办法!#火影忍者 #佐助 #家庭
00:33
Motor Controls - Contactor and Power Circuit
13:18
IMAT
Рет қаралды 137 М.
How To Connect 2 Alarm Zones With Only Using 1 Alarm Wire.
10:29
Lighting Circuits Part 3 - Fans, Motion Sensor Lights, 3 Core & Earth Cable
25:50
How do Cats Eat Watermelon? 🍉
00:21
One More
Рет қаралды 12 МЛН