Significant improvement can be made utilising a circuit diagram of the windings and ground to illustrate the tests. It would very much aid in understanding the practical tests.
@michaelcostello6991 Жыл бұрын
Nice lesson. Also good to remind people of the danger so we do not get complacent. Thanks Michael
@PatrickLulama Жыл бұрын
I had to watch this video because returning to college we will doing this...now i have an understanding thank you so much this helped alot😅❤.
@pistolcrossbow3 жыл бұрын
Thanks for this video :D It realy helped me out. I got my motor running now.
@PatrickLulama Жыл бұрын
And thank you for informing us about danger hazards
@tehking111 Жыл бұрын
You should really use insulation resistance test between earth and phase at double the working voltage. That way you get an actual reading instead open loop. Same for phase to phase. I don't know what the range is on your meter but if it only goes to like 100k ohms then you might weak short and not detect it. A fail is less than 1M ohm. Also worth noting if you put a star bar in, you can phase to phase test while checking balance by going u1 to v1, v1 to w1, w1 to u1.
@BubbleheadDiver Жыл бұрын
Thank you - great video!
@granatapfel66613 жыл бұрын
Resistor Widerstand (Das Ding an sich) Resistance ist der Widerstand (Wert den du ausdrücken möchtest)
@ralfbrauckmann97513 жыл бұрын
Vielleicht sollte noch darauf hin gewiesen werden die Stern bzw Dreieck Brücken vor den Messungen zu entfernen :-)
@et5m3 жыл бұрын
Wer will mehr Englisch Video? :D :D
@maxi00773 жыл бұрын
Bleib liaba beim boarischn des ligd dir und mir bessa ☺️
@kEnavity_103 жыл бұрын
Bitte nicht
@marinaschmidleitner38313 жыл бұрын
Ich 😊
@PatrickLulama Жыл бұрын
I do because it is easier for me to understand and I loved your 1st video so much easier nd understanding 😅
@hachimankmd5843 Жыл бұрын
Sorry to break it to you but that's a big NO. You have to disconnect your coils and the power cable before proceeding with measurements.
@PatrickLulama Жыл бұрын
Now i am lost lol I am a level 2 student 😢and we will be testing our motors returning on the 17 July now I am lost😅
@christophercolumbus8944 Жыл бұрын
is this three phase motor. ?
@Ben-lw6jfАй бұрын
Yeah because of the U1 V1 W1. That indicates its a 3 phase motor
@SirEpifire2 жыл бұрын
Me trying to diagnose a 240V shop compressor at home. 👀 💦
@whynot90682 жыл бұрын
What makes this dangerous? It doesnt look like the motor is receiving volts.
@fearlessreview2 жыл бұрын
Precaution for someone t/s on unit installed lol you never know
@TheJimbobjimmy3 жыл бұрын
Isn’t that resistance quite high?
@choohong10352 жыл бұрын
Smaller motor usually has higher ohm, and bigger motor has smaller ohm
@christophercolumbus8944 Жыл бұрын
@@choohong1035 hey do you know why a motor stops working after a few seconds of power? ? what could be the issue?
@choohong1035 Жыл бұрын
@@christophercolumbus8944 motor run by contactor or vfd? Or you should try check motor ohm, running motor amp if possible, or bearing problem maybe?
@PatrickLulama Жыл бұрын
Starting winding is the one with a higher resistance am i right😅?
@Nico_jo3 жыл бұрын
Welches Multimeter hast du? :-)
@et5m3 жыл бұрын
Das amzn.to/3ttxCJz
@hendrikm90353 жыл бұрын
Nächstes Video dann bitte auf Französisch.
@et5m3 жыл бұрын
Gerne
@PatrickLulama Жыл бұрын
And then what about us as level 2 students whom understand English only😅
@leonard31152 жыл бұрын
Good, aber why 'infinity'? This is not accurate, oder?
@darkness43828 ай бұрын
Loop
@granatapfel66613 жыл бұрын
Dieser deutsche Akzent aus Bayern
@halmeer84933 жыл бұрын
Dialekt trifft es besser aber du hast schon recht, man hört es durch 😊
@dersenfi8063 жыл бұрын
In der Reihenfolge?
@akramkadhim90552 жыл бұрын
Resistance check between the two screws??? For what? I don't think this measurement is important or necessary
@Teknopottu2 жыл бұрын
He is checking the resistance of the windings. If they are far off/no resistance, winding can be shorted or broken. He is also checking for the resistances between the three windings. If they have even some resistance in between, the can be shorted and/or broken. Each winding has to be separate from each other and from the ground. The star/delta connections between windings have to be removed for this to work, he forgot to mention it. Replying to an old comment but hopefully this helps.
@bengunn36982 жыл бұрын
@Akram He is checking between the earth terminal in the motor connection box and the frame of the motor to ensure there is electrical continuity , zero ohms. This is to make sure that when you connect the earth wire to the earth terminal you are earthing( grounding) ALL of the motor frame , not just the screw.
@At-Imperial-Walker2 ай бұрын
Horrible...no rhyme or reason...
@christianwareham5164 Жыл бұрын
Bad learning video. Your going through each test but not explaining. Just w1 w2 infinity lol terrible.
@gnaflethegarthok30742 ай бұрын
Annoying accent
@TheCanciller Жыл бұрын
You have no idea about electricity. Stop it buddy os dangerous!!!