"R" is for reference (not return loss) and is a "portion" of the source signal that goes into your device. "A" and "B" receivers receive the signals that you want to measure against the reference (A/R and B/R are measured) so B may be the output of the device so B/R is S21 and A may come from return loss bridge so A/R is your S11. That's how these instruments were used. We had one at school back when I was a student...
@NimbleJack3
@NimbleJack3 3 жыл бұрын
+1. This is how the channels are intended to function. There are actually dedicated bridge products designed to plug into an input channel and provide both directional coupling and RF power measurements with high precision.
@jafinch78
@jafinch78 3 жыл бұрын
Neat to see the innards of the HP8757A. The older designs are so easy to work on if needed... pending parts availability or DIY knowledge enough to customize suitable. Looking forward to firing up the PMI/Wavetek 1038's this season since I don't have sensors yet for the Gigatronics and HP power meters. Finally scored a set of service and operation manuals for the NS20 and NS206/207... not the NS201's I have three of... however I think enough to read through to boost my confidence enough so I don't damage anything and can better reverse engineer if I wanted to use as signal generator. ESD fear! Guessing like the N10, I'll have a bunch of buttons to replace.
@herbertsusmann986
@herbertsusmann986 3 жыл бұрын
Amazing how all that old test equipment that used to cost $20K+ (in those dollars) is now either $50 or free today. I have a lab full of that kind of stuff, still works. They were built to last from HP and Tek (except HP scopes....). Quality parts through and through. Before the bean counters took over at HP.
@NimbleJack3
@NimbleJack3 3 жыл бұрын
Only the unusable trash costs $50. There's still many working examples of antique HP tech out there in labs and on the market for hefty sums. This 8757 is relatively worthless due to the unknown performance and self-test fails - it's more money than it's worth for anyone to try and restore it to working order and/or calibrate it, unless you are an enthusiast who is willing to potentially perform component-level repair. Hence why it never sold on craigslist.
@NimbleJack3
@NimbleJack3 3 жыл бұрын
I advise against ramming little bits of wire into the data inputs. Those things have voltage rails on them, and shorting them to ground or the data lines is a great way to break what's left of the analyser.
@IMSAIGuy
@IMSAIGuy 3 жыл бұрын
Don't worry "I'm a professional'
@AECRADIO1
@AECRADIO1 3 жыл бұрын
A, B, R, WITH 'R' BEING THE COMBINED INPUT/OUTPUT, POSSIBLY.
@NimbleJack3
@NimbleJack3 3 жыл бұрын
A and B are the test channels, while R is the reference. The idea is that you can use R to measure the power before it enters the device under test, then measure the power after and display it as an A/R or B/R ratio. This setup could be used to characterise 3-port linear devices such as a power splitter, or to measure both the S11 and S12 of a two-port device at the same time (by using a coupler or bridge).
@KEVINPAGEkf4znl
@KEVINPAGEkf4znl Жыл бұрын
What is a "DUT" and where can I get one for my for my HP 8752A ? Thank You de KF4ZNL
@IMSAIGuy
@IMSAIGuy Жыл бұрын
DUT stands for device under test
@KEVINPAGEkf4znl
@KEVINPAGEkf4znl Жыл бұрын
@@IMSAIGuy OH OK Thank you
@davidr4210
@davidr4210 3 жыл бұрын
what is the difference between the 8757 and 8756? i heard the 8756 are a pain to cal and adjust, but are they harder to work with too?
@IMSAIGuy
@IMSAIGuy 3 жыл бұрын
I have no idea, sorry
@nickcaruso
@nickcaruso 3 жыл бұрын
Maybe I missed it but why is it scalar? Does it only measure the real part, or one part at a time?
@NimbleJack3
@NimbleJack3 3 жыл бұрын
It's scalar because the inputs are only for power level data from external detectors (the predecessor to power sensors). They have no way of measuring the phase of a signal, just the instantaneous RF power level moment to moment.
@nickcaruso
@nickcaruso 3 жыл бұрын
@@NimbleJack3 thanks!
@RobB_VK6ES
@RobB_VK6ES 3 жыл бұрын
Can you use the TG built into your HP SA?
@IMSAIGuy
@IMSAIGuy 3 жыл бұрын
Yes I could probably get it working but it would require sensors and cables (way too expensive)
@NimbleJack3
@NimbleJack3 3 жыл бұрын
EDIT: I am mostly wrong, see below. No. To my knowledge, the 8757x family is only designed to work with dedicated signal generators that have a compatible "source interface" DB connector (such as the 836x0 sweeper, or its' successor the PSG).
@IMSAIGuy
@IMSAIGuy 3 жыл бұрын
@@NimbleJack3 nope, this one is HPIB
@NimbleJack3
@NimbleJack3 3 жыл бұрын
@@IMSAIGuy Oops, you are right - total brain fart. Yes, it's a GPIB control, but there's also three auxiliary BNC connectors for sweep, stop sweep, and z-blanking required. I don't think a spec an will be able to work.
@IMSAIGuy
@IMSAIGuy 3 жыл бұрын
@@NimbleJack3 It also required a 27.777khz modulation
#654 Holiday Tour of the Shop
13:26
IMSAI Guy
Рет қаралды 2,2 М.
HP 8568B 1.5 GHz Spectrum Analyzer Repair
26:04
CuriousMarc
Рет қаралды 73 М.
规则,在门里生存,出来~死亡
00:33
落魄的王子
Рет қаралды 27 МЛН
HP8757D Scalar network Analyzer
24:57
tgsoapbox
Рет қаралды 6 М.
#1548 Bad Circuits from the Art of Electronics
15:43
IMSAI Guy
Рет қаралды 59 М.
#1368 10W 30dB Attenuator
8:04
IMSAI Guy
Рет қаралды 9 М.
#869 HP 8711C Hacked into HP 8712C VNA
13:46
IMSAI Guy
Рет қаралды 4,1 М.
Using a Photomultiplier to Detect Single Photons
26:24
Huygens Optics
Рет қаралды 78 М.
TA-0422: Siglent SDS824X HD vs Rigol DHO924 - 12 bits - Hands On
28:04
Flawless PCB design: RF rules of thumb - Part 1
15:45
Hans Rosenberg
Рет қаралды 72 М.