Sir aaap ko rock bottom basic level se - high level Tak ka perfect knowledge hai and specialist of all SMPS circuit Apki sab video without any time waste perfect aur simple hai. I am very very impressed by you ,,👍
@mohamedantri9433 Жыл бұрын
روعة الله يعطيك العافية استاذنا الفاضل أشرف على معلوماتك القيمة وجعله في ميزان حسناتكم استاذنا ❤❤❤❤❤
@HaseebElectronics Жыл бұрын
الحمد للہ
@Somanathan-hj7ge11 ай бұрын
Sir, today again i was watching this video,wow what a clear explanation,and perfect testing of transformer of microvave. and your videoes are very useful for everyone,who is dealt with electronic knowledge, you are awasome sir,app dilsey sikhate, with safety 😊a lots of respect and thankyou very very much ❤
@saarike Жыл бұрын
Very good explanation and schematic!!! Thank you.
@HaseebElectronics Жыл бұрын
You are welcome!
@Somanathan-hj7ge Жыл бұрын
Super testing high voltage, cold checking is good,I think, resistance checking is not dangerous 😊 sir, thankyou
@HaseebElectronics Жыл бұрын
yes resistance test is safe but this live test provides an accurate health status of the transformer
@waltercohenganem-vf3en3 ай бұрын
Muy buena explicacion Gracias
@SuperNadeemraoАй бұрын
اسلام وعلیکم بھائی اسکی جگہ سوئچ موڈ پاور سپلائی لگا سکتے ہیں ؟ اسکی پاور سپلائی بنانا سیکھائیں
@asim200533 Жыл бұрын
AoA Sir need your help Make a video on NCP1200,what is Dynamic self supply how it generates Vcc for itself.. I am facing an issue in it
@sudhirpatil34342 ай бұрын
Very nice explained sir!
@HaseebElectronics2 ай бұрын
Thanks and welcome
@cedm2373 ай бұрын
Hello, for measuring the secondary of the transformer with the 2M and 2K resistance bridge, what kind of resistance do you use? (carbon, metal film, metal oxide?)
@alamagordoingordo30474 ай бұрын
Very explanatory, thank you.
@oscarvalenzuela262 Жыл бұрын
Excellent demostration!! thanks a lot...got a like!!
@HaseebElectronics Жыл бұрын
best regards
@andymathabela24207 ай бұрын
such a good explanation👏
@shafimehar450610 ай бұрын
Assalamualaikum sir.I have one sharp microwave oven. I check the ohms value of HV terminal with body.it shows 75.4ohms.rest of the values are matching with your video.If so,is it considered good or bad.please clear my doubt
@HaseebElectronics10 ай бұрын
HV transformer's (high voltage winding) one end is connected to oven body and the second end goes to HV diode and capacitor if you are getting reading with HV terminal and oven's body. that is good indication that the winding's second side is making good connection
@vanellopevon2666 Жыл бұрын
Veery good explanation.❤❤❤❤
@vijayakumarkumar9190 Жыл бұрын
Very useful information thanks
@HaseebElectronics Жыл бұрын
So nice of you
@biomedicalengineering7374 Жыл бұрын
You are fantastic. I take alot of information from your videos . Thanks alot .
@HaseebElectronics Жыл бұрын
most welcome dear brother it is my pleasure
@biomedicalengineering7374 Жыл бұрын
@@HaseebElectronics thank you 🙏.. I wish to explain the how can we check the ic electronic on the board
@ehdresf.ibrahim3 ай бұрын
Salam sir. Can you share a circuit diagram to measure high voltge side of a microwave oven transformer. Because i want to make a circuit also.
@khanlalavlogs Жыл бұрын
Excellent sharing brother.
@HaseebElectronics Жыл бұрын
Many many thanks
@ElaheTorshiziBargooi-fj1nb7 ай бұрын
thank u for this video
@technicalcracker89265 ай бұрын
sir ,i made this kit exactly according to the diagram,with same resistors and thier wattage, but when i tested it,i tested it for 4 seconds,and my new multimeter got blown,thanks it was a cheap clampmeter.sir whats the reason ,can you explain it sir?
@yusufdeen816110 ай бұрын
Good teaching
@ahmedabdelrahman3712 Жыл бұрын
Very good video
@HaseebElectronics Жыл бұрын
best regards
@aanishkadailydose Жыл бұрын
Good job Bhai
@HaseebElectronics Жыл бұрын
thanks a lot dear sister
@home9tv19 ай бұрын
Transform readings all OK but sparking and blasting, magnetron reading OK, capacitor reading OK, diode not short. How test?
@susantaatha6468 Жыл бұрын
Nice information
@HaseebElectronics Жыл бұрын
it is my pleasure
@anilg197211 ай бұрын
if primary winding resistance is showing 6ohms and hv winding resistance is 212ohms than what is the condition of the transformer
@vijayakarekar Жыл бұрын
Thanks sir ji....
@HaseebElectronics Жыл бұрын
Welcome
@muhammadishtiaq24 Жыл бұрын
Weldon keep sharing
@HaseebElectronics Жыл бұрын
it is my pleasure
@mpasapaulsam67779 ай бұрын
I've noticed about 3.5vac at magnetron connection, can't i use a transformer whose output 3.5vac and feed it to the magnetron in that position of the microwave for testing for the heat
@RXSVN_25 ай бұрын
3.5vac is the low side voltage used for the vacuum tube filament inside the magnetron. But 1,800 to 2,800 volts is the high side voltage needed for the magnetron to heat.