When you bridge the capacitor with insulated pliers (and not a resistor), does that not damage the capacitor? Any damage 'in circuit'? Thank you!
@HaseebElectronics Жыл бұрын
indeed it tends to draw maximum current from the capacitor. and it will not damage it. but the best way is to discharge the capacitor using any load to prevent sparking
@jaym5938 Жыл бұрын
@@HaseebElectronics Thank you! Sparking scares me ;) I will build the device you're using!
@therealjammit Жыл бұрын
It doesn't electrically hurt the cap, but the sparks might probably start "welding" off metal from the leads.
@m1983n1 Жыл бұрын
Thanks for sharing technical secrets and knowledge's.Inmy knoledge no other chanel like yours.very deeply explained practically and theoriticaly. God bless you sir🙏🙏
@fringeminority56767 ай бұрын
Wow! You just brought my OTR troubleshooting to the next level. I'm gonna make this tool asap. Currently after voltage testing the primary terminals at transformer all my other tests in the hv circuit are done using ohms. Problem with ohms tests is, if it tests bad component is bad, but if ohms tests good it can still be bad. Doing this hv testing I can now be 100% correct on the defective part. Thank you so much sir, I'm subscribed
@EidyRamazy8 ай бұрын
Your video about Trans Microwave was great, thank you
@olisahopene9475 ай бұрын
excellent videos
@dayalolive Жыл бұрын
Thank you for sharing this, really helpfull circuit.....🙏🙏🙏🙏
@HaseebElectronics Жыл бұрын
it is my pleasure
@TABE-O Жыл бұрын
Great trick that one Haseebi!! Thanks!!
@muhammadishtiaq24 Жыл бұрын
Informative video keep sharing
@Radhapzr2 ай бұрын
very nice explanation.
@jimmybonges4512 ай бұрын
Good day Mr. May I ask you something a little outside of the HV Capasitor in this uour video. I have Sharp Micowave that using HV Dioda, part number is HVR-1X 4 which connected from 1pin of the HV capasitor to the chasis. This dioda was defected/shorted affected the main fuse was always blown off. I’m encountering difficulties to find that dioda. My question is, Can I replace the above part number HV dioda with the part number is HVR-1X 3. Your suggestion is much apprexiated🤝
@Ianf1x Жыл бұрын
So you have made a shunt to make voltage Safe for meter 😊 very nice 👍
@HaseebElectronics Жыл бұрын
indeed it is voltage divider circuit. same as it is used in high voltage probes
@m.mudassar6318 Жыл бұрын
خوبصورت انداز ❤
@HaseebElectronics Жыл бұрын
شکریہ پیارے بھاءی
@AbdullahAli-hv5ym Жыл бұрын
MarshAllah Allah Mubarak jazakallah khair 💕
@hiz-n-lowz1577 Жыл бұрын
Hi, great vid, im confused how just a diode and capacitor is acting as voltage doubler, isnt it just acting as your typical half wave rectifier circuit to supply pulsating DC to magnetron? also does the HV from capacitor go through the magnetron and towards the ground on the other side of magnetron or does it go through the other winding that is going to magnetron? Its very confusing to me in the wiring diagram, it looks like the magnetron is connected to the - side of the capacitor and therefore no voltage is getting to magnetron..... thanks
@khalidraja5327 Жыл бұрын
Good idea 👍
@ChrisHalden007 Жыл бұрын
Smart solution. Thanks
@willsxd0 Жыл бұрын
Saw your picture for the first time in reflection of meter screen🎉
@HaseebElectronics Жыл бұрын
wow so nice
@willsxd0 Жыл бұрын
@@HaseebElectronics i ve been a student of u in practical electronics its an honour to get a reply from you thanks for everything sir
@voeurnsear6033 Жыл бұрын
Thank you for sharing a great video for us.
@aghilmousavi7450Ай бұрын
باسلام وسپاس عالی بود.OK
@W1RMD Жыл бұрын
Thanks for sharing this practical circuit with us.
@HaseebElectronics Жыл бұрын
it is my pleasure
@AbdulMomenZargar60 Жыл бұрын
Shaam Bakher Ho Bhai Sahib
@ladbla1752 Жыл бұрын
Thank you for sharing your idea.
@mohamadmansour2595 Жыл бұрын
Most test leads of Multimeters rated 1000v if it is good brand, precautions must be taken when using cheap Multimeters.
@HaseebElectronics Жыл бұрын
yes you are exactly right
@protection4541 Жыл бұрын
Hi engineer Do you need an oscilloscope to repair the inverter board of all types of air conditioners
@HaseebElectronics Жыл бұрын
welcome dear yes. oscilloscope is very important tool in modern electronics circuits. using oscilloscope we can see the signal shape and behavior, specially in microprocessor based signals
@diyaialgarah9914 Жыл бұрын
شكرا جزيلا لجهدك النبيل
@RXSVN_2 Жыл бұрын
Excellent
@HaseebElectronics Жыл бұрын
best regards 💕
@YoutubeBaruHamid Жыл бұрын
Makasih ya sdrku sudah berbagi informasi nya 👍❤️
@mohamedantri9433 Жыл бұрын
الله يحفضك من كل سوء استاذي الكريم ويزيدك من علمه ...وشكرا على الرد ....❤❤❤❤❤
@adiseshukumpati24 Жыл бұрын
useful sir😊
@umarboss99 Жыл бұрын
aslam o alikum sir mery pass ek ic h jes k oper Q100 lekha h or nechy vf26 is ka koi equitant mel sakta h ? or es ki datasheet bhi bta dain shukriaya
@umarboss99 Жыл бұрын
vf26 h ya ve26
@susantaatha6468 Жыл бұрын
Excellent. Thank you sir.
@DesiMekar Жыл бұрын
sir..if we provide 220v in HV coil..so we get low voltage in 220v side
@miloradgraovac74 Жыл бұрын
Brare JA sam koristio kombinirke,nego primi TI od srca velike pozdrave❤
@HaseebElectronics Жыл бұрын
hvala puno dragi brate
@palwindersandhu2031 Жыл бұрын
Thanks very much sir....
@twk4223 Жыл бұрын
7:10 Are the Cap Discharging line of resistor (20k Ohm) and the Cap Measuring line of resistors(2M Ohm +2k Ohm) joins at Common? As you moved too fast I could not see them clearly.
@HaseebElectronics Жыл бұрын
20 K resistance one end for discharging point for capacitor 2nd end is connected to common terminal and 2 K resistance 2K resistance 2nd end is connected to voltage measurement terminal and 2M ohms resistance 2M ohms resistance is connected to high voltage test point
@twk4223 Жыл бұрын
@@HaseebElectronics Thank you for the clear instructions on the Cap Discharging cum Measuring Tool! About 5 weeks ago, I managed to repair my Sharp MW oven replacing the HV Cap and the oven was able to function for the next 2 weeks before it wreaked havoc again. This time round, the turntable, fan and light were on whenever the door is opened though the "Start" button is not pressed. Later, I found out that the Primary Door Switch button is stuck and with the replacement of the micro switch it was able to function normally. Because whenever I discharged the HV Cap, I just short it with 2 screw drivers then a plier which I don't really like to do so. Finally, I found your great informative channel with so many interesting contents. If I am not mistaken, you must have gotten this electronics skills through college education, which I feel safe and comfortable unlike other channels that do not follow the proper way of doing things correctly! Thanks for all your uploads that I may find some useful. Thank you!
@siavash8379 Жыл бұрын
👏👏👏👏 great
@HaseebElectronics Жыл бұрын
best regards
@hugoegon8148 Жыл бұрын
Take care to use probes made for measuring this HV. Stay safe and healthy. 😊
@lelmus3277 Жыл бұрын
To measure 5V?
@hugoegon8148 Жыл бұрын
@@lelmus3277 No, the probes for the tool attached to the HV test points. It seems he used normal multimeter probes , that are usually rated for 1000V. That could be dangerous if the HV is much higher.
@HaseebElectronics Жыл бұрын
you are right the bribes quality must be better to meet HV safety. these probes are normal multimeter probes.
@lelmus3277 Жыл бұрын
@@hugoegon8148 I stand corrected.
@arunkumar-bh2dp Жыл бұрын
useful information, but how to calculate the resistor value for this high voltage testing. according ohms law or any other else
@German_byte Жыл бұрын
Thank you. I wonder if some technicians have been killed by microwave ovens.
@HaseebElectronics Жыл бұрын
bets regards indeed it is the most dangerous item in the world
@technicalcracker89265 ай бұрын
hello sir, i have made this tool ,i used 2.2k resistor and 2.2mega ohm insted of 2 because of non availability at shop.i used 220v,but the multimeter is showing nothing,why?
@Trucam2020 Жыл бұрын
Thanks. I think that your multimeter probes don't allow voltage measurements above 600-1000 v
@HaseebElectronics Жыл бұрын
best regards. you are right the multimeter probes fall in safety class in 1000 volt. we can select high voltage probe or we can add some extra layer of insulation.
@electroniquepassion Жыл бұрын
👍😉
@HaseebElectronics Жыл бұрын
thanks a lot
@shefqetkaralliu6816 Жыл бұрын
👍
@arpir97 Жыл бұрын
And do not break the ceramic parts of the magnetron, especially the pink part, it is made of Beryllium ceramic. Inhalation of microdoses of Beryllium causes fatal beryllium cancer in the lungs.
@crazyfactstnmy8 ай бұрын
This is resistor or high voltage diode
@HaseebElectronics8 ай бұрын
it is high volatge diode www.alldatasheet.com/datasheet-pdf/pdf/445594/DACHANG/CL01-12.html
@crazyfactstnmy8 ай бұрын
@@HaseebElectronics you say in video 2m ohm resistor