I had the same problem at one point. The contactor was the cause, it was stuck on the closed position. Good video. We have to thank the guys who take time to share information.
@Buster-im5so Жыл бұрын
Dave, this problem plaques my condenser as well. Now I'll look for frayed wires. Thanks dude... yours is the only video I've found on this subject.
@huntgibson37162 жыл бұрын
Great fix Dave. That's a new one for me too. In my experience, this situation has always either blown the low voltage fuse or tripped the breaker. Thanks for sharing!
@ApartmentMaintenancePro2 жыл бұрын
Thanks for watching Hunt!!
@Honestandtruth0074 ай бұрын
@@ApartmentMaintenancePro My Goodman has Same issue. I appreciate for the video 👍
@RScottMelton Жыл бұрын
I would suspect the wire was like that from the factory. It just took years of vibration and insulation degradation to finally short it out. Good troubleshooting logic and info. Thanks!
@kangzau1006 Жыл бұрын
Very cool that you did the troubleshooting directly on camera
@davidjoines8497 Жыл бұрын
Thanks for your posting I checked my capacitor and yes I had a dead mouse across the capacitor I cleaned it off and by gosh it now works perfectly. So grateful for your insights. Thanks again
@noelelnolo9642 Жыл бұрын
Excellent video, great job looking for the culprit.
@MediaArchitects Жыл бұрын
You helped me take care of my 92 year old mother’s Air conditioner that wouldn’t shut off. The aged electrical contactor was stuck in the down position. I will be replacing it thanks to you.
@bobster99 Жыл бұрын
I appreciate you posting this video. My problem was actually the Contactor. I am in Florida and ants seem to love electrical boxes and that includes the A/C Shut off and pretty much any place that is dark and protected. I found the electrical connection area of the Air Conditioner filled with ants and it appears that a couple of unlucky ants got between the contacts and when the thermostat energized the contactor relay the ants got fried and stuck the contacts together. Luckily it is winter in Miami and I was leaving for the weekend so I didn't need A/C and had time to order a new contactor and a spare capacitor (they don't seem to like the heat down here either). If this would have been August I bet I could have pried the contacts apart and it would have worked long enough to order a new one but luckily I didn't have to find that out. Thanks Again!
@ApartmentMaintenancePro Жыл бұрын
Glad you got it goin!!
@DJV940226 ай бұрын
You mean termites 😂
@Honestandtruth0074 ай бұрын
Thank you for your Video I think I will Look into inside the Compressor wires. Maybe it Short too😮😊@@ApartmentMaintenancePro
@michaelfarfan307211 ай бұрын
Great job. Glad you searched for the main issue. And, not just changed out contactor. Thanks for the video it will Definitely help me.
@primerodinero29093 ай бұрын
you just helped me solved my problem ... the contactor was stuck ... thank you so much ...
@chazbOE39 Жыл бұрын
I had this issue on my Bryant plus 80 Conditioner, and i agree with this guy about swap out the CONTACTOR, IT WAS STUCK ON
@joeyysossa41442 жыл бұрын
Great job...visual inspect is always first...
@LexVance2 жыл бұрын
Crazy! Making memories Dave! 🤣 Great video man!
@ApartmentMaintenancePro2 жыл бұрын
Thanks Lex! Always fun to run into crazy issues like this :) well, sometimes
@remmyerickson47799 ай бұрын
I loved the troubleshooting. It helped me check off what it could be.
@thriftypsgr Жыл бұрын
Headed to a service call right now for this issue. I hope this video helps
@fernanduslewis21012 жыл бұрын
dude you save me....this one video was the reason mine was doing the same thing.....wire melted on canister all i had to do was tape and separation witn zip ties....keep doing your thing dude....i bought new contactor which was defective from amazon....and a capacitor and i had a new defrost board from years back....
@ApartmentMaintenancePro2 жыл бұрын
Nice job! Glad you got the problem fixed lewis 🛠
@rickavelar628 ай бұрын
Great video, I just had a hockey puck style safety switch and condensate pump installed inside my condo.I noticed the next day, my fan outside runs all the time with a/c off ? , and the lines are freezing up.I'm thinking they didn't wire it up correctly, I'm calling the HVAC company, to come back to see if they caused the problem, or maybe it's just a coincident . Thank you for helping me with the video !!!
@ApartmentMaintenancePro8 ай бұрын
Hard to tell without a full diagnosis but good call on getting the hvac company back out 👍
@carlgreen22322 жыл бұрын
I have seen heat pumps back feed lv from the relays inside and do this as well..Paint pens work great to label the units also.
@ApartmentMaintenancePro2 жыл бұрын
Right on Carl thanks for the input!
@fernanduslewis21012 жыл бұрын
please explain about back feeding to the air handler relay?
@MaintenanceMan002 жыл бұрын
Great video and an even greater view from up there
@ApartmentMaintenancePro2 жыл бұрын
Thanks Evan 🙏
@theopappas18904 ай бұрын
I hope this wasn’t the issue at a recent Goodman call
@Jose23-g8h23 күн бұрын
Thnx ,sir realy helps ,
@DJV940226 ай бұрын
If its a lennox the defrost board starting off new out the box can have the defect of internally having yellow and red bridged when its suppose to be seperate circuit
@TheDradgeАй бұрын
Why is there no rubber grommet in the sheet metal hole? I'm not an AC tech but I am an electronics engineer. I'd never have wires going through sharp sheet metal without some type of plastic or rubber grommet.
@garrettmandujano2996 Жыл бұрын
Just had this come up for me, we’ll see if mine is the same fix, thanks!
@ApartmentMaintenancePro Жыл бұрын
What did you find?
@garrettmandujano2996 Жыл бұрын
@@ApartmentMaintenancePro a customer called saying this was their issue, I asked if the batteries had been changed in their thermostat, they told me they had. The first thing I checked was the thermostat and I noticed corroded old batteries, so some new ones went in and the confesor fan stopped running upon receiving the new signal.
@ApartmentMaintenancePro Жыл бұрын
@@garrettmandujano2996 Good first instinct 👍
@edbtzkhud Жыл бұрын
My compressor stays running for about a minute or so after the inside unit turns off. Any idea what it could be?
@ApartmentMaintenancePro Жыл бұрын
Contactor could be arcing welding itself shut. Of course, this is just a guess that could be wrong
@demtriustriplett92226 ай бұрын
great gaddamit work buddy i have the same issue currently .in chicago ,thanks !!
@deepbludude469711 ай бұрын
Good job Tshooting! So im dealing with a condensor fan that started running slowly constantly with Tstat off, its been in heat cycle for 2 months. im guessing maybe the cap is bad or a short. Gonna go out there in the morning and inspect thanks for posting.
@seattlebest799 күн бұрын
Thank you for the video.
@billbliss2500 Жыл бұрын
I’m glad I watch this because I have a carrier unit that the condensing fan motor keeps running, and the thermostat is satisfied in the blower fan motor in the furnace is shut off. However, I replaced today the capacitor that was bad, but the condensing motor now stays running and is never satisfied and shut off. I also checked the contact block and the contacts are in perfect shape. I also had the other day refrigeration guy come in at 11 ounces of refrigerant, that’s all it was low. So I don’t understand why the condensing fan motor continues to run???? If I turn The thermostat to off it Drops the coil out on the contactor. I also Took out the condensing fan motor when I went to get a new capacitor. I mentioned that because the video showed the wire that was shorted to the frame but in this case the wires were fine no shorts to ground.
@ApartmentMaintenancePro Жыл бұрын
It’s getting constant power somehow. Possibly miswired
@MRM-wp4gr Жыл бұрын
I have this same problem on a Guardian 5 ton unit. All the wiring looks fine and all connections are tight. Could it possibly be a bad contactor? Or what else could cause this. The fan seems to be getting 110v from somewhere because it only turns slowly and heats up to 130* until the compressor kicks on and brings the fan up to full speed, then the motor cools off.
@cr-qk4wd2 жыл бұрын
Awesome vid, Thank you.
@rionavarro83817 ай бұрын
nice work Mark Ruffalo
@PhilipAlonzo2 жыл бұрын
Thats a cool tester
@BlacHaze78 Жыл бұрын
Why didn’t you put in a rubber grommet? The problem will eventually happen again.
@alexgg74996 ай бұрын
Mine the thermostat moves itself to 65 keep running what is it
@larrynone63548 ай бұрын
I'm having this problem and I can't figure it out. I replasterered the motherboard, and it does exactly the same thingI replaced the contactor and the same I've checked all the wires and no shorts. Is it possible for the copasitator to keep it running.
@franciscojavierestrada7585 Жыл бұрын
Yes i hate those single pole contactors have to be extra careful
@sixtygrit99442 жыл бұрын
Good find!
@curtisthrow5743 Жыл бұрын
I used markers but I label inside power block boxes
@ApartmentMaintenancePro Жыл бұрын
I'd rather see that than markers exposed to the outside. Paint pens and markers will last maybe a few years before fading when outside.
@brandonpierce1729 Жыл бұрын
Would this make the inside fan blower run continuously as well?
@ApartmentMaintenancePro Жыл бұрын
No, but a bad relay or thermostat would
@jamesmungal25592 жыл бұрын
Why it didn't tripped the breaker? Since it was a short to ground?
@carlgreen22322 жыл бұрын
Breaker is far away sometimes if they are far enough it won't trip.
@fernanduslewis21012 жыл бұрын
@@carlgreen2232 mine is doing the same thing it kicks the breaker when u turn on the air and the outside unit breaker kicks
@justwork_hvac2 жыл бұрын
great fix.thanks for sharing
@mrsalsamafia4 ай бұрын
Nice job, thank you.
@michaelsorrentino-cx5nx7 ай бұрын
Same problem found shorted fan wire
@TheColergruver2 жыл бұрын
Wow, good find!
@ApartmentMaintenancePro2 жыл бұрын
Thank you!!
@jcaleca60 Жыл бұрын
That's a hell of a critter factories out west have to buy special Transformers to create another phase this little critter created a sine wave to get to 220 very smart critter
@marcos.aguilar1013 Жыл бұрын
Mine is strange, I turned the heating on and it's just not stopped running now for about 2 weeks. I'm gonna figure out how to fix it now.
@alfredhines50510 ай бұрын
Bro, u have a welded contactor.
@Honestandtruth0074 ай бұрын
How funny it's my Goodman has Same issue Compressor turned On and Off. ...even i changed New Contactor single Pole as Original. Oh boy I have to LOOK for the SHORT too😮😔
@retrothruster25396 ай бұрын
This saved me! Mine turned out to be the contactor like the post below, very much appreciated!! Sub'd/liked!!
@LuisFlores-hl5zf Жыл бұрын
You got it bro
@swflscratcher5893 Жыл бұрын
I got the same problem but capacitor is replaced and it’s still doing it
@MaintenanceGuy-sp1ll Жыл бұрын
It's more than likely the contactor.
@swflscratcher5893 Жыл бұрын
@@MaintenanceGuy-sp1ll bope
@swflscratcher5893 Жыл бұрын
@@MaintenanceGuy-sp1ll nope
@MaintenanceGuy-sp1ll Жыл бұрын
@@swflscratcher5893 if it's not the contactor which is the most common problem than a bad relay or wire
@crama19638 ай бұрын
Excellent
@blackarm3265 Жыл бұрын
Thanks very good
@rifathasan4139 ай бұрын
Thank you
@c21meister2 жыл бұрын
Goodman and their horrible wire runs
@HandyLotion Жыл бұрын
Shared
@atanaciomaldonado3943 Жыл бұрын
Haaaa is something wrong everyday see something
@minutebooks32454 ай бұрын
Another video that is directed at people with HVAC experience. The rest of us idiots are completely lost. Lots of terms that aren't explained. I have no idea what you are doing or why.