A/C unit Turned into an ICE MACHINE!!

  Рет қаралды 10,883

Quality HVACR

Quality HVACR

Күн бұрын

SAVE 50% on your first two months with HOUSECALL PRO
housecallpro.p...
- SUPPORT THE CHANNEL -
www.patreon.co...
- Check out @TruTech Tools, LTD -
www.trutechtoo... (Use promo code “QUALITYHVAC” to save 8%)
- HVAC TACTICAL -
hvactactical.com/ (Use Promo Code "QUALITYHVAC" to save 10%)
- FOLLOW ME -
Instagram: @qualityhvacr
- BUSINESS INQUIRES -
qualityhvacrtn@gmail.com
- TOOLS I USE -
Veto ProPac SB-LD:
amzn.to/3zf4Jsb
Milwaukee M12 Vacuum:
amzn.to/4e6N2Ke
110v Transfer Pump:
amzn.to/4dec0aK
Milwaukee Crate:
amzn.to/4fymnr9
Fieldpiece SM380V Digital Manifold: www.trutechtoo...
Fieldpiece Job Link HVACR Charge & Air Kit: www.trutechtoo...
Solderweld Brazing Kit:
trutechtools.c...
Fieldpiece DR82 Leak Detector:
trutechtools.c...
hilmor lineset cleaning kit:
trutechtools.c...
RLS Refrigerant Press Tool Kit:
www.trutechtoo...
Veto Pro Pac MB5B Tool Bag:
trutechtools.c...
Supco Jumper King:
trutechtools.c...
Fieldpiece VP87 Vacuum Pump:
trutechtools.c...
Fieldpiece MR45 Recovery Machine:
trutechtools.c...
Fieldpiece Hose Kit:
trutechtools.c...
Fieldpiece SR47 Refrigerant Scale:
www.trutechtoo...
Fieldpiece SC480 Meter: www.trutechtoo...
Fieldpiece SC680 Meter: www.trutechtoo...
Supco Magnetic Umbrella: www.trutechtoo...
Supco Coolpressor:
trutechtools.c...
Supco Jumper King:
trutechtools.c...
HVAC unit leaking water. How to clean HVAC drain line.
#qualityhvacr #hvac #repair

Пікірлер: 61
@codeybrown1108
@codeybrown1108 5 ай бұрын
I’ve had that problem at least a few times before & this time it was actually caused by that exact kind of drain trap used on that one. The systems are normally a 3 ton or bigger & when the blower fan is either on a higher speed or is just big like a 5 ton, the fan is blowing so strong, that it causes a very strong vacuum & it sucks air backwards up the drain line & that trap is not deep enough to stop or counter act the vacuum strength & it causing the system to not drain fast enough or “properly”. That is why there was so much water in the drain pan still. The large amount of water in there & the humidity in there just quickly cause the system to freeze up. Especially in the rainy season like right now during the summer time. The other day I tried to vacuum out a drain line and got almost absolutely nothing, I was suspecting that maybe someone probably purposely poured like super glue in the drain line or something, so I then pulled the entire underground drain line out & completely replaced it with a new drain line, after I got it out it was completely clean. Then after I put the new line, I put an extra deep trap on it. After I returned the next day everything was working perfect. It took me an hour or two thinking about it & just trying different things the day before, but I finally found that the trap was the problem. Also, I forgot to say earlier, that the air handler was in the attic and it was leaking into the ceiling and the drywall was starting to fall. It was all caused by the strong vacuum of the blower motor 👍 If that helps all you guys at all. Leave me a like. Thanks Guys.
@martinberkovics9194
@martinberkovics9194 5 ай бұрын
I actually had the same problem that the blower was sucking all the water out of the drain pan, and it was leaking all over, I tried putting in a deeper and wider trap but it didn't help, I ended up putting a sponge in the drain pan to hold the water down and it worked fine after that.
@ZERO-F2G-
@ZERO-F2G- 5 ай бұрын
@@martinberkovics9194 What was the static pressure on the negative side? A standard 3/4 p-trap should have no issue with negative pressure unless it is well out of range. Running traps or no trap at all often due even in normal conditions. If you have a clear as in not clogged drain with a properly vented P-trap, and the pan still holds excessive water, you could be massively out of level, but more likely undersized ducts causing excessively high static pressure on the negative side.
@newportreds6710
@newportreds6710 4 ай бұрын
so interesting! thanks!
@whiskeycast3785
@whiskeycast3785 5 ай бұрын
They changed the filter 20 mins after they called you
@AaronPowellvox
@AaronPowellvox 5 ай бұрын
I get that one so much. Then they’re ashamed that it was filthy and you have to pry the information out of them.
@SusanMackey-p5e
@SusanMackey-p5e 5 ай бұрын
Agreed A plugged filter sounds more realistic of the cause since no other issues found..They probably checked it after they called you and the plugged filter is sitting on top of the trash can?
@kgshvacservicesllc
@kgshvacservicesllc 5 ай бұрын
I've dealt with this at least 10 times this year
@Climaster
@Climaster 5 ай бұрын
I check the trash can and 90% the old filter is there . Could be the contactor sticking. I like to double check the ductwork . Sometimes is like you said , blower or txv failing randomly
@jaymiller4060
@jaymiller4060 5 ай бұрын
I’m sure someone has said this already but it could be the contactor sticking.
@FirstGenNationn
@FirstGenNationn 5 ай бұрын
please do more of these am about to get in the field after college thanks!!!
@howardblasingame7961
@howardblasingame7961 5 ай бұрын
HVAC is the best trade for a lifetime career
@liltp4809
@liltp4809 4 ай бұрын
It’s either the filter dirty back side of your Evap coil if you have a txv at the evap coil the super heat should be higher at like 20 degrees
@dustinwilliams5399
@dustinwilliams5399 5 ай бұрын
Just ordered my SB-LD bag
@mylesmackey2430
@mylesmackey2430 4 ай бұрын
In the video, it looked like the return duct was separating from the unit. If you’re constantly pulling in hot outdoor air, it’ll have a hard time satisfying on hotter days
@OutdoorRhodes
@OutdoorRhodes 5 ай бұрын
Check filter, shut system on and off by thermostat. Maybe thermostat is issue not calling for fan.
@DavidHernandez-gt9bo
@DavidHernandez-gt9bo 5 ай бұрын
Nice video . Keeping all troubleshooting options on the table ! How’s it been going since a few videos back you mentioned buying an additional local AC business / expanding . Solid work always !
@gas_man1565
@gas_man1565 5 ай бұрын
something u probably should have done was to see if the unit actually turned on and off thru the thermostat. and if the tstat is operating properly. maybe the drain is clogged and the water slowly evaporatored onto the coil. now that will depends if they had the ac running during cold nights, suction temp could have gotten down to below 32 (the SH is still there. so the compressor wont over ice up. but if the drain was clogged thats a possibility) i agree come back in a week or so and see how its running good video
@nikeij13
@nikeij13 5 ай бұрын
I saw everything okay. Maybe dirty filter and sometimes too much water still water for too kong can cause it to freeze. Not 100 % all the time, but it has happened to me. It's just one of those mystery frozen units lol
@Dalan612
@Dalan612 4 ай бұрын
Possibly a small piece if debris that plugs up the txv in cooling mode but when ran it heat it frees back up?🤔 I’d say the dirty filter is more likely. They don’t ever want to admit to it though…
@vincentgelles3805
@vincentgelles3805 5 ай бұрын
Sticking contactor most likely. Did you inspect it and check for pitting?
@ZERO-F2G-
@ZERO-F2G- 5 ай бұрын
Are they using either ecobee or nest power stealing thermostats? As those models have documented history of ghost like blower issues. For what reason did you replace the IBM? We have had to replace a dozen or more x13 motors in ICP products in the last two years, mostly do to cavitation issues, and or unit freezing up when everything checked correctly, and the issue was the IBM would occasionally drop out on a call.
@josepagan9236
@josepagan9236 5 ай бұрын
Emc blower or TXV OR Contactor filter dirty and customer replaced
@monojnath8446
@monojnath8446 5 ай бұрын
Hi good morning 🌄
@brianjones7983
@brianjones7983 5 ай бұрын
The first shot of that evap coil looked a little dirty. When you get that much ice buildup and the coil has a lot of dirt, the ice will actually pull most of it off the surface as it falls off. Probably where some of that junk in the bottom of the unit came from.
@johncraig406
@johncraig406 5 ай бұрын
We need to get our manufacturers back here in the USA, please Vote accordingly.
@dustinschupbach2709
@dustinschupbach2709 5 ай бұрын
What are they setting their thermostat to? Could be running it to cold and the unit never shuts off. Unit should have a freezstat 🤷‍♂️
@ice4278
@ice4278 5 ай бұрын
Maybe. The txv has a partially clogged filter.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 5 ай бұрын
Why more manufacturers don't use freeze stats....I don't know. They would've stop this. That is one thing carrier did that was smart....CLO board and a freeze stat.
@johnamez909
@johnamez909 4 ай бұрын
I have a question about the drain lines the primary has a float switch and a tee before the P trap wich is always blowing cold air, and the emergency second drain just has a 90 degree elbow face down to the pan also blowing cold air is this the right install ?this was done 3 years ago.
@ScottDavis-f7x
@ScottDavis-f7x 5 ай бұрын
Did you verify the airflow rate? Maybe the airflow was low causing the evaporation coil to freeze up. Did you check the filter dryer for a delta T across it (indicating a liquid line restriction)?
@finitttoooo
@finitttoooo 5 ай бұрын
I went to one recently system running fine but after 30 mins the return flex would start to slowly collapse flat
@tc7922
@tc7922 5 ай бұрын
Chasing the ghost… ugh….Round one of hide and seek …. Goes to the machine …
@ManuelLopez-t8f
@ManuelLopez-t8f 5 ай бұрын
Txv
@mansourramzey7711
@mansourramzey7711 5 ай бұрын
Weather dropping in temperature and being ran on the same temperature as outside might have something to do with it, idk
@fernandosremodeling7337
@fernandosremodeling7337 5 ай бұрын
I have the same problem with my house
@bassam1992MR
@bassam1992MR 5 ай бұрын
Wait this has a gas furnace and a heat pump? Never seen that! Most likely i wanna sat TXV.
@lonestarcatapults5561
@lonestarcatapults5561 5 ай бұрын
What pants do your wear?
@robalexander7348
@robalexander7348 5 ай бұрын
Interesting fault Zac, lets see how it performs from now on 🤔 Au
@search_eternal
@search_eternal 5 ай бұрын
I want to say it was a clogged air filter.
@OnusBones
@OnusBones 5 ай бұрын
Low air flow; maybe too many closed or clogged registers?
@kevinlawson8124
@kevinlawson8124 5 ай бұрын
If not low air, thermostat was set to low!
@asafegous
@asafegous 5 ай бұрын
Exchange the malfunctioning blower for a new one
@owensotak9498
@owensotak9498 5 ай бұрын
It did this unit was a package unit does both heat and cool with no unit inside
@johnwalker890
@johnwalker890 5 ай бұрын
Air flow issue or TXV issue, charge didn't look low.........
@raytinsman7815
@raytinsman7815 5 ай бұрын
Sticking contactor
@tuffram2165
@tuffram2165 5 ай бұрын
ECM blower with high static pressure guaranteed.
@JesseDoesHVAC
@JesseDoesHVAC 5 ай бұрын
Did you watch the recent HVAC school vid on the heat pump roll out
@VictorS-mr7jc
@VictorS-mr7jc 5 ай бұрын
Low split 13.7 degree 🤔
@willhoward3052
@willhoward3052 5 ай бұрын
Dude drilled a hole in the panel door 💀
@BurtBartlow
@BurtBartlow 5 ай бұрын
Umm....filter?
@AndrewGalvan-bb5vz
@AndrewGalvan-bb5vz 5 ай бұрын
Looks like a faulty ECM Module, turning off then on randomly
@rivercrafters
@rivercrafters 5 ай бұрын
Ecm motor?
@RobertTuck-vo8cw
@RobertTuck-vo8cw 5 ай бұрын
Please five some feedback if you have to go back there.
@weswg
@weswg 5 ай бұрын
Bet they had a dirty filter
@matthewprewer5197
@matthewprewer5197 5 ай бұрын
Control board not energizing blower
@jonathanwillard171
@jonathanwillard171 5 ай бұрын
Probably a X-13😢
@thesilentonevictor
@thesilentonevictor 5 ай бұрын
Just wait you will find your answer
@bruce744
@bruce744 5 ай бұрын
Um excuse me could you have that thawed out and repaired in 15 minutes? I have a tee time!
@LouisS-cs7bh
@LouisS-cs7bh 5 ай бұрын
Another reason not to go with all this high tech junk!!
@spyda2038
@spyda2038 3 ай бұрын
I love your channel but this is just content like ASMR . Watchers dont learn nothing
Unable to Repair 4 Year Old HVAC Unit…Homeowner is Furious! 😡
15:37
This Was a TERRIBLE Install….Until Now
16:29
Quality HVACR
Рет қаралды 36 М.
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН
When you have a very capricious child 😂😘👍
00:16
Like Asiya
Рет қаралды 18 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
Is Your A/C Unit About To Die? This Tool Doesn't Lie
10:03
The DIY HVAC Guy
Рет қаралды 272 М.
HVAC Contractors Hate Me For Showing You This
22:34
Ambition Strikes
Рет қаралды 686 М.
LEAKING coil on a Trane package unit.
13:27
Quality HVACR
Рет қаралды 13 М.
No HEAT Call in a Tennessee Blizzard!! HVAC Repairs
8:48
Quality HVACR
Рет қаралды 40 М.
Every Time On The Weekends It Stops Working
20:39
HVACR Survival
Рет қаралды 15 М.
Typical HVAC unit LEAKING refrigerant & How I Fixed it.
17:37
Quality HVACR
Рет қаралды 57 М.
HVAC Ladder Crane Redesigned For Any Job Under $275
11:28
HVACR Survival
Рет қаралды 47 М.
THE ICE MACHINE IS NOT PRODUCING
21:43
HVACR VIDEOS
Рет қаралды 59 М.
Commerical HVAC Heating Repairs | Mistakes were Made...
24:15
Quality HVACR
Рет қаралды 30 М.