AASHTO T 27 - Sieve Analysis

  Рет қаралды 19,282

Cttp Arkansas

Cttp Arkansas

Күн бұрын

Пікірлер: 9
@CristianoRonaldo-sn2kq
@CristianoRonaldo-sn2kq 2 жыл бұрын
WE USED IT IN OUR PRESENTATION. VERY VERY VERY VERY VERY BENEFICIAL!!! ATILIM UNIVERSITY INCEK ANKARA. WAITING FOR THIS MAN HERE TO EAT HATAY DURUM. IT IS OUR TRADITIONAL FOOD. YOU MUST TRY IT.
@senaitesfai9660
@senaitesfai9660 3 жыл бұрын
Nice Description. Pls post other vidios.
@richbruno8682
@richbruno8682 2 жыл бұрын
What is the industry standard for mechanical sieving time? Is it 5-7 minutes?
@cttparkansas4219
@cttparkansas4219 2 жыл бұрын
RichardBruno, I would agree that 5-7 minutes is generally a good time frame but the specs tell you to verify this on a yearly basis. You ideally want the run time to be 10 minutes or less so as to not cause degradation of the sample. If you take a look at Annex A2 in AASHTO T27, they go into detail on how to verify the time of your mechanical shaker. The short version is you want to verify after running your shaker for X amount of minutes that its within tolerance. To be in tolerance, you need to make sure no more than 0.5% by mass of the total sample before sieving passes any sieve after 1 minute of contiuous hand sieving.
@wyattfuchs8079
@wyattfuchs8079 2 жыл бұрын
should you not have zeroed the scale out before placing the bowl and then zeroed the bowl? @ 31 seconds
@cttparkansas4219
@cttparkansas4219 2 жыл бұрын
Hello Wyatt, it makes no difference rather you zero the scale out before placing the bowl on the scale or not. It wouldn't of hurt anything if you did so, but the important thing is to make sure you zero the scale AFTER placing the bowl on the scale. The whole idea is making sure we are taking the weight of the bowl out of our weight prior to weighing the aggregate. That way we get a true weight of the aggregate only. When zeroing, it is also important to remember to only use the exact same bowl that you tared out (though they can look identical, all bowls weigh differently when we are weighing as low as to the nearest 0.1g).
AASHTO T 21 - Organic Impurities
1:42
Cttp Arkansas
Рет қаралды 18 М.
AASHTO T 27 Sieve Analysis of Coarse and Fine Aggregates
11:56
TC3 (tc3.transportation.org)
Рет қаралды 45 М.
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
Try this prank with your friends 😂 @karina-kola
00:18
Andrey Grechka
Рет қаралды 9 МЛН
AASHTO T 11 - Washing
4:11
Cttp Arkansas
Рет қаралды 13 М.
Gradation/Sieve Analysis
10:34
ugptindsu
Рет қаралды 32 М.
Fractured Faces
4:11
CIVL3820 Auburn Univ.
Рет қаралды 7 М.
AASHTO T248, Reducing Samples
17:32
Jon Havens
Рет қаралды 23 М.
Sieve Analysis
7:40
Elementary Engineering
Рет қаралды 494 М.
Grain Size Analysis and Hydrometer
24:19
UVA TTA, Virginia's LTAP
Рет қаралды 59 М.
7 Outside The Box Puzzles
12:16
MindYourDecisions
Рет қаралды 200 М.
Standard Method for Sieve Analysis of Fine and Coarse Aggregates (ASTM C136)
5:51
Blackboard AASHTO T27-ASTM C136 - Apple TV (3rd Gen.)
11:39
james Lee (TechTraining)
Рет қаралды 20 М.
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН