@josephfiganiak
@josephfiganiak 3 жыл бұрын
Thanks for making this series of videos. Was able to diagnose and fix my issue over 2 days. My issue was not getting low voltage from blower board out to the condenser. Wound up checking for continuity on the two wires in use and was getting bad readings. Swapped out another pair in the same jacket tested for continuity and 24v. Hooked everything back up and sent power. Contactor engaged right away and I have AC again! Thanks again, if anyone is watching these videos please remember to be safe. If you are not comfortable hire someone. Playing with a lot of power working on an AC condenser unit, NO JOKE!
@tommyperez6377
@tommyperez6377 5 жыл бұрын
Wow you went step by step on what you're doing, i haven't found a video that does that. Instant Subscribe!
@TuanPham-qq3pg
@TuanPham-qq3pg 2 жыл бұрын
By the way I love how you show an nice and clear video of what you doing. I like learning new things on Hvac. Thanks
@jamesrooney7689
@jamesrooney7689 2 жыл бұрын
i was surprised it did not trip the fuse great video SAM there is no one even close to you you explain everything
@anthonynguyen8031
@anthonynguyen8031 Жыл бұрын
I must say your videos are clear and concise. I am not in the field but enjoy learning about HVAC.
@toantran1
@toantran1 4 жыл бұрын
Thanks Sam, all your videos are great to watch and learn.
@vetdadcubby4722
@vetdadcubby4722 3 жыл бұрын
Great tip in the meter temp probe reading, Thanks Sam!
@justinberrett7479
@justinberrett7479 5 жыл бұрын
Thanks We love a.c. videos. Straight to the point.
@realestateinfonet9041
@realestateinfonet9041 3 жыл бұрын
Very nice work! Outstanding results! Congratulations!
@mrlatnemis1849
@mrlatnemis1849 5 жыл бұрын
LOVE YOUR VIDEOS👍🏽. WELL EXPLAINED!!👍🏼
@brianturner9657
@brianturner9657 5 жыл бұрын
Thank you. Amazing that The simplest things can shut down a system
@Hvacmania
@Hvacmania 5 жыл бұрын
Nice detective work. Good job 👍
@ryandaddy2044
@ryandaddy2044 2 жыл бұрын
dude you are awesome keep up the videos my man!
@joepah51
@joepah51 5 жыл бұрын
Never saw a wire nut problem before.. well done! Hope you were able to install the plastic cover on the outside connection box..
@drwlpwasright5132
@drwlpwasright5132 5 жыл бұрын
Joe Pah All the time. That's because of lazy mechanics not using electric tape properly around the wire nut.
@abdorakeebnaji1527
@abdorakeebnaji1527 5 жыл бұрын
Great explanation .👍👍
@robinroberts2803
@robinroberts2803 5 ай бұрын
very very helpful ♥️ thank you so very very much ♥️
@jennyleung6537
@jennyleung6537 5 жыл бұрын
thank you, i have a long way to learn.
@jennyleung6537
@jennyleung6537 4 жыл бұрын
thank you, i wish you are my teacher.
@franko1334
@franko1334 5 жыл бұрын
Excellent !!!
@mikeyboy2154
@mikeyboy2154 5 жыл бұрын
thanks love your videos always learn a lot
@abrahammiron8319
@abrahammiron8319 5 жыл бұрын
Great video 👌
@leeleviner8159
@leeleviner8159 5 жыл бұрын
so cool thanks
@jessehoffman3269
@jessehoffman3269 5 жыл бұрын
Thanks for the temp prob tip I'll to compare the two
@abrahamvaro1637
@abrahamvaro1637 5 жыл бұрын
Very nice videooo,thanks
@tmst2199
@tmst2199 5 жыл бұрын
But *why* does the temp gun give an incredibly low reading when pointed at the vent?
@HNT63
@HNT63 5 жыл бұрын
Nice
@ljslw
@ljslw 2 жыл бұрын
If there is 24v at the thermostat and not at the contactor then it’s a matter of following the low voltage wires from the contactor to the thermostat looking for a break in the wire, correct?
@JuanMorales-ks4ll
@JuanMorales-ks4ll 4 жыл бұрын
excelente
@JGR088
@JGR088 Жыл бұрын
What if you don't have voltage from c, and y at the furnace control board? Does that mean I have a bad board?
@remushaynes2693
@remushaynes2693 5 жыл бұрын
i am interested in temp. guns and wondered if the southwire you use is better than others or if you have it as a matter of company issue? if there is a real good but inexpensive one please advise. thank you.....g
@MoreThanMaintenance
@MoreThanMaintenance 5 жыл бұрын
Temp guns only give the surface temperature and does not give you the temperature of the moving air. Example... if I point my temp gun in the vent it is giving me the temperature not of the moving air but of the actual duct itself. The K type thermocouple however is more accurate in giving you the temperature of the air flowing through the vents. Both are useful in the field. Both are fairly reasonably priced. The temp gun about $50 and the wire or k type thermocouple about $20. Hope that helps and thank you for the question!
@remushaynes2693
@remushaynes2693 5 жыл бұрын
no, actually i am familiar with the operation as you described. my query was southwire as opposed to other brands. which is preferred, better, cheaper, etc......g
@cavemanjoe7972
@cavemanjoe7972 2 жыл бұрын
@@remushaynes2693 Southwire, general, lots of decent temp guns out there. As long as you're not using one made for body temps, it'll be alright.
@pdgearhead3504
@pdgearhead3504 5 жыл бұрын
It appears that the filter was installed upside down. The arrow was aiming down and, I believe, should be aiming up. May not be significant, though.
@pollydor07
@pollydor07 3 жыл бұрын
Thanks
@TuanPham-qq3pg
@TuanPham-qq3pg 2 жыл бұрын
What happened when my condenser not running, but my main breaker is shaking.
@conradkalb4464
@conradkalb4464 3 жыл бұрын
Low voltage wires in the same disconnect box with high voltage wires?
@cavemanjoe7972
@cavemanjoe7972 2 жыл бұрын
Yeah, they all get run through the same conduit.
AC not Working! MUST WATCH! Multiple Issues FIXED!
24:46
Finding Low Voltage Shorts Fast! HVAC Troubleshooting!
11:42
AC Service Tech LLC
Рет қаралды 487 М.
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 958 М.
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
AC Not Working. Troubleshoot Condenser
5:14
Sam
Рет қаралды 14 М.
AC Not Working? Service Call Beginning to End!
8:14
Sam
Рет қаралды 35 М.
Understanding HVAC Schematic Basic Wiring EASY!
18:43
AC Not Working? Simple Diagnostic Step by Step.
6:48
AC Not Working... Contactor Not Getting VOLTAGE
10:02
Sam
Рет қаралды 308 М.
How to Diagnose Low Voltage Short Easy! HVAC
10:18
Sam
Рет қаралды 246 М.
How to Check AC Freon Level
16:41
Word of Advice TV
Рет қаралды 2,1 МЛН
Furnace Troubleshooting Step by Step with Multi Meter.
26:33