I need to speed up my truck. Where do I find it in the menu ? Thank you in advance
@th3vidal3 жыл бұрын
Hi, where i can get the default parameter list, the machine model is 8fbmt45
@1600GSI3 жыл бұрын
You can also set each controller to default settings in the dashboard, but then you will have to teach in/calibrate different sensors when using the default setting option.
@until214810 ай бұрын
Do you know how to reset the password on a Hyundai 25B-9u?
@1600GSI10 ай бұрын
No, I don't have any info for this model yet.
@andrebaltar45944 жыл бұрын
I need you help to solve a problem in one forklift like that. Can you help me?
@1600GSI4 жыл бұрын
What is the problem
@andrebaltar45944 жыл бұрын
@@1600GSI I have one electric forklift, Toyota 8FBMT25-12246, and its showing 3 errors: 6BB; 4FE and 4FC. I think that those error are related with one unexpected removal of the battery box. And I think that nothing is wrong with the forklift and I only need to reset de Main Control Board error. But I dont know how. The forklift runs, and the steering pumo is running, but the fork is not moving.
@1600GSI4 жыл бұрын
@@andrebaltar4594 6BB Electronic Valve Control Board: Load 1 Shorted. (Problem with circuit piloting descent and lift solenoid valves coil short-circuiting) 4FE Traction Control Board: V_bat_KO. (Not receiving 24V power - contacts of contactor K2 open) 4FC Traction control board: SWING_LOAD_OPEN. (Problem with auxiliary outputs of the Traction Control Board Card)
@1600GSI4 жыл бұрын
@@andrebaltar4594 6BB check all the connections of the valves including the valves (18ohm lift lower) (28ohm others) for short circuit. 4FC valve L10 open check connector P85 4FE Contactor K2 faulty 1) check DC DC converter 24V 2) resistance coil K2 605Ohm 3) is there a reading of 80V controlling K2? 4) The condition of the plates and contacts of contactor K2 (oxidation or dirt? If there is no 24V power supply the EVCB maybe detects a break in wiring or short circuit.
@andrebaltar45944 жыл бұрын
@@1600GSI First of all, thank you for so fast help. I will explain to you the situation. I am not a forklift technician. I am working in a Power plant at an Island and we rent here the forklift. We went against a water pipeline with the forklift and all the fork lift went wet. But it was working. After that we remove the battery box to dry it and after assembly it again the fork didnt move anymore. So we are quite desperate with the situation because we really need the forklift and here is difficult to rent another one and there is no forklift technician able to solve the problem... Is it possible for you show me where those valves are? By showing me pictures or drwaings? Another think we tryed to reset somethings in that menu that you show on that video and now is showing another 2 errors : BEB and 6F3...