Great video sir. Straight to the point and clearly explained
@southernyankeerobinson23345 жыл бұрын
Just took this test on 09/21/19 and failed my first attempt for not asking for the correction factor at the end so please do not forget to ask that!!!
@JSSTyger4 жыл бұрын
@@aulajomaa6286If you are taking the ACI Grade One test, your company should provide you with the relevant ASTM standards. You will need to know slump, temperature, air content, and cylinders. You will need to know proper sampling. You will also need to know the dreaded roll-meter, which is used to determine air content for lightweight concrete. I've been doing testing for 15 years and I've only used a roll-meter on (2) jobs.
@JSSTyger4 жыл бұрын
@@aulajomaa6286 I work in Ohio and needed Grade I ACI to test concrete in the field. We had a written portion and then had to run all the tests in a lab (2 types of air tests, temps, slump, make cylinders).
@ZootedSnake4 жыл бұрын
@@JSSTyger how do you know what the initial pressure is?
@JSSTyger4 жыл бұрын
@@ZootedSnakeThe initial pressure for a new pot is in print on the neck of the top piece. Sometimes the pot needs re-calibrated and the initial pressure would be determined during calibration. The IP should always be marked somewhere on the pot.
@ZootedSnake4 жыл бұрын
JSSTyger ok thank you
@alexschatz13 жыл бұрын
Nice video I just passed the exam Nov 16, 2021
@PrometheanFrErunning3 жыл бұрын
Do they time this test ?
@alexschatz13 жыл бұрын
@@PrometheanFrErunning no they don’t the only test that they time is the slump and it’s 2:30 min
@GooseGoss1963 Жыл бұрын
I appreciate all the skipping past the first part, but I struggle with knocking every bit of air out of the vessel before taking the compression test. It seems to me that if it was in a controlled area that it would maintain that air?? or am I wrong
@Gulyus Жыл бұрын
This is why the test emphasizes the flat surface of concrete in the first half of the test / the start of this video. A flat surface of concrete will be right up against the bottom of the pressure chamber. That is also why you put the water into the petcocks. Once water is standing in both petcocks there is no non entrenched air inside of the pot. The concrete is right up against the bottom of the top piece (top of the chamber) and any air that is trapped is pushed out by the water introduced. You then pressurize the top valve with air - then until you press the air valve on top and hit the side of the pot there is no connection between the air in the top and the pot, therefore there is no air introduced to the lower chamber until the time where the test is taken.
@jesusglopez84303 жыл бұрын
Excellent very educative and informative Thanks.
@noeorozco50543 ай бұрын
how much should u be getting pay if you pass this test?
@robertoreyes35882 жыл бұрын
Great video can someone help me to give me an advice how to calibrate my air pot
@mdnt_ramble73 жыл бұрын
Why do you pump it up with petcocks open? How’s it hold the air?
@witherskeletonfilms28513 жыл бұрын
The air chamber is closed off to the rest of the air meter bowl. Whether the petcocks are open or closed it doesn't change anything. Once he depresses the main air valve, it raises a pin inside the air chamber that releases the air into the air meter bowl.
@mdnt_ramble73 жыл бұрын
@@witherskeletonfilms2851 thank ya
@engineeringbook89559 ай бұрын
Why need ip until 2 not zero
@CameronDude5 ай бұрын
Passed today
@rocknjap22 жыл бұрын
You didn’t release all the pressure in the chamber before putting the lid on the pot. That makes your tests not uniform
@awrangzibalkozai4390 Жыл бұрын
Great
@empireaxe88523 жыл бұрын
Why did u not show the first steps?? Filling the pot with concrete, 3 layers rodding 25 times each tap 10-15 times each etc. If you’re gonna show the test show the whole thing