ACI Density Test: ASTM C138 Density (Unit Weight) 2019

  Рет қаралды 97,671

SI Certs

SI Certs

Күн бұрын

Пікірлер: 36
@underthenorthernstar
@underthenorthernstar 2 жыл бұрын
I’m ACI certified for field tech grade 1 but I still come back to these videos because they’re so well made. Good work
@MuhammadFayaz-jd6tn
@MuhammadFayaz-jd6tn Жыл бұрын
dear which test include grade1?
@ZiaKhan-cf9xi
@ZiaKhan-cf9xi Жыл бұрын
What is aci....
@underthenorthernstar
@underthenorthernstar Жыл бұрын
@@ZiaKhan-cf9xi American Concrete Institute
@aletapearce2369
@aletapearce2369 2 жыл бұрын
no gloves?
@jesusglopez8430
@jesusglopez8430 Жыл бұрын
Thanks for sharing.
@babarzia9281
@babarzia9281 2 жыл бұрын
(Weight of concrete + Weight of empty measure) - weight of measure / volume (32.865 - 7.79) lb / .25 FT CUBE 100.3 LB/FT CUBE IS THE DENSITY
@Tranceporter33
@Tranceporter33 2 жыл бұрын
32.865 lbs is the weight of the concrete without the weight of the container/mold. So you're subtracting 7.79 lb that was Already Subtracted. That's where the error is.
@andrewharwood7033
@andrewharwood7033 Жыл бұрын
We do that so different in Australia.
@jacksongatlin5418
@jacksongatlin5418 7 ай бұрын
Because you’re all criminals
@HectorLopez_
@HectorLopez_ 4 жыл бұрын
NICE SKECHERS
@ВоваСкуйбеда
@ВоваСкуйбеда 2 жыл бұрын
「あなたの動画はとても良いですし、メッセージがた
@kromekicks
@kromekicks 5 жыл бұрын
Is the required frequency of this test daily or weekly per mix design?
@Chibi_Sentai
@Chibi_Sentai 4 жыл бұрын
kromekicks depends on the job and what engineers want you to do
@Greyskullill
@Greyskullill 2 жыл бұрын
Some projects it's daily, fdot it's a must..some commercial projects also
@ghostlyOne00
@ghostlyOne00 Жыл бұрын
How did you get the mold volume
@nothingtoseehere3839
@nothingtoseehere3839 Жыл бұрын
All meters come machined to a precise size from the manufacturer, 0.25 cuft
@sangwanyi4469
@sangwanyi4469 7 ай бұрын
By measuring the weight of water of the container considering volumetric correction factor depending on water temperature.
@juliusclarkparana7654
@juliusclarkparana7654 2 жыл бұрын
32.865÷0.2504=131.25
@michaelparionaramos4097
@michaelparionaramos4097 5 ай бұрын
Where is the weight of empty measure?
@babdabubda5266
@babdabubda5266 5 ай бұрын
@@michaelparionaramos4097 The pot was tared, meaning that when he took the empty pot off of the scale after the scale was zeroed, the scale reads the negative weight of the empty pot. So when he puts the pot back on to the scale when it's filled, it subtracts the weight of the pot for you. That allows you to essentially weigh ONLY the mass of concrete. Doing that means that you don't actually have to use the mass of the empty pot in the equation.
@michaelparionaramos4097
@michaelparionaramos4097 5 ай бұрын
@@babdabubda5266 Thank you very much for the brilliant explanation.
@babdabubda5266
@babdabubda5266 5 ай бұрын
@@michaelparionaramos4097 Haha of course man, have a good one.
@AlexRodriguez-lk1jy
@AlexRodriguez-lk1jy 5 жыл бұрын
sweet, thanks
@rarecandy3445
@rarecandy3445 2 ай бұрын
heard him tap the bottom with the rod
@22udubfan
@22udubfan 2 жыл бұрын
Sir, you don't zero the scale AFTER you get the tare weight. Pointless to get a tare weight if you zero it out. Therefore your math is now wrong.
@gabrielkramer9164
@gabrielkramer9164 2 жыл бұрын
Hey Jimmy, you record the weight prior to the tare. You can see this graphic representation on the screen as we do it. As long as you note this, you can account for it in the end. There’s more than just a single way to do this.
@orendarisingprod.6419
@orendarisingprod.6419 2 жыл бұрын
Well with most if not all calibrated scales once you get the weight of the pot and get the tare the scale resets to 0 then once the pot is removed it would show into the negative. Example. If the pot is 8lbs and you get a tare down to 0 once the pot is removed the scale will read -8lbs if I’m not mistaken.
@splash6450
@splash6450 11 ай бұрын
@@tanumie2657 To prevent concrete from sticking, making it easier to clean. Keep your tools happy, and your tools keep you happy.
@josecauich8790
@josecauich8790 5 жыл бұрын
is the math correct?
@MegamanBillydaKid
@MegamanBillydaKid 3 жыл бұрын
I think it’s wrong I got a different result! I got D=100.3
@eritimes
@eritimes 2 жыл бұрын
Safety issue! No gloves, concrete is caustic to the skin.
@curtisw831
@curtisw831 2 жыл бұрын
Some of us don't have an issue with it
@fadedace1342
@fadedace1342 2 жыл бұрын
Hes using fly ash, but yes you can get some pretty bad concrete burns from this
@rickelliott777
@rickelliott777 Ай бұрын
Man Up😂😂😂 Ur right
ASTM C231 - Air Content of Concrete by the Pressure Method
6:47
Cttp Arkansas
Рет қаралды 102 М.
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 684 М.
River Raider Snorkel Install Part-10
9:54
Recon Jeeper
Рет қаралды 5
ASTM C138   Standard Test Method for Density (Unit Weight), Yield, and Air Content of Concrete
4:51
Heidelberg Materials North America
Рет қаралды 16 М.
ACI ASTM C231 - Air Content: Pressure Method 2019
2:41
SI Certs
Рет қаралды 182 М.
What’s the Deal with Base Plates?
13:31
Practical Engineering
Рет қаралды 1,2 МЛН
3  Concrete Slump
6:11
Nwader Factory
Рет қаралды 55 М.
Turbo Fan Dusters are getting out of hand
14:08
Torque Test Channel
Рет қаралды 1,4 МЛН
ASTM C31 - ACI Making & Curing Concrete Test Specimens 2019
2:05
INECYC DENSIDAD  DEL HORMIGÓN ( ASTM C138)
6:48
Inecyc
Рет қаралды 22 М.
Арыстанның айқасы, Тәуіржанның шайқасы!