ACS Essential - Flue Terminal Types Explained

  Рет қаралды 1,917

Pass Your Gas

Pass Your Gas

Күн бұрын

Пікірлер: 18
@abdulh63
@abdulh63 2 жыл бұрын
great video again. thank you
@izetagaci1038
@izetagaci1038 Жыл бұрын
Thank you
@Ed-fp9rx
@Ed-fp9rx 2 жыл бұрын
Fantastic video, Thank you
@passyourgas
@passyourgas 2 жыл бұрын
👍
@passyourgas
@passyourgas 2 жыл бұрын
🙏
@Михаиллеви
@Михаиллеви 2 жыл бұрын
Thanks. A topic not covered really by others
@1stevew
@1stevew 2 жыл бұрын
Superb.... thank you.... another brilliantly explained video
@passyourgas
@passyourgas 2 жыл бұрын
🙏
@Ed-fp9rx
@Ed-fp9rx Жыл бұрын
Hi pass your gas, how do you find the cross sectional area of a chimney? especially round chimneys? i see in the books it says the cross sectional area needs to be a certain size but nowhere shows you how to find this out, love the videos thanks alot
@passyourgas
@passyourgas Жыл бұрын
Hi Ed…it’s simply done ..here goes- square or rectangular chimneys .. measure 2 sides in cm and then multiply them together. Example.. if one side is 20cm and the other 30cm then 30 x 20 = 600cm2 … if it’s a round flue then measure in cm across the widest part … then half that number and write it down. Now whenever you’re dealing with anything circular you must use the “magic” circle number called pi. This is just a word that means 3.14 So write down 3.14 then write down the number from before twice. Multiply everything and you’ll get your answer. Example.. you measure the widest part of the flue and let’s say it’s 30cm. Half it = 15cm Use pi = 3.14 So 3.14 x 15 x 15 = 706.5cm2 I hope that helps! 😀 If you still don’t understand let me know!
@hgh6791
@hgh6791 2 жыл бұрын
Thanks 🙏
@passyourgas
@passyourgas 2 жыл бұрын
You’re welcome. Let me know if your struggling with anything I haven’t covered and I’ll make a video for it. Thanks for commenting. Good Luck.
@abdulh63
@abdulh63 Жыл бұрын
I always come back to your videos, just so much info! Can't thank you enough. I have a question in regards to spillage testing, I know its done to prove POC are being taken away. But somtime I wonder what the difference is compared to a smoke bomb test. For instance on a floor standing open flue boiler or back boiler you would do a smoke bomb test under the draught diverter, this test produces a lot a smoke and if this test passes then why would you not expect a spillage done in the same location under the draught diverter to also pass, only difference i can see is the amount of smoke produced. If a lot of smoke is being pulled up then wouldn't you expecte a bit a smoke to also get pulled up? And hence POC to get pulled up too. I dont know if im making sense, Thanks
@passyourgas
@passyourgas Жыл бұрын
Hi Abdul… you are testing 2 completely different things. 1. The smoke bomb is carried out with the appliance OFF, it can actually be completely removed (like a gas fire). This test is to test the structure of the FLUE. It checks that there are no leaks and that flue can carry that amount of product. If the flue is cracked or not complete then you need lots of smoke to see where the leaks are. 2. The spillage test is carried out with the appliance ON and is testing that the VENTILATION AIR SUPPLY TO THE ROOM is sufficient to supply enough air for the flue to work when the appliance needs s n and all the doors and windows etc are closed (restricting the air supply) All you need to know for this test is that the ddd is sucking air in..so no need for masses of smoke. I hope this helps. Cheers
@passyourgas
@passyourgas Жыл бұрын
Hi Abdul… you are testing 2 completely different things. 1. The smoke bomb is carried out with the appliance OFF, it can actually be completely removed (like a gas fire). This test is to test the structure of the FLUE. It checks that there are no leaks and that flue can carry that amount of product. If the flue is cracked or not complete then you need lots of smoke to see where the leaks are. 2. The spillage test is carried out with the appliance ON and is testing that the VENTILATION AIR SUPPLY TO THE ROOM is sufficient to supply enough air for the flue to work when the appliance needs s n and all the doors and windows etc are closed (restricting the air supply) All you need to know for this test is that the ddd is sucking air in..so no need for masses of smoke. I hope this helps. Cheers
@abdulh63
@abdulh63 Жыл бұрын
@@passyourgas thank you again!
@EuanAlmighty
@EuanAlmighty Жыл бұрын
You added up the vent holes wrong on the brick. Pretty sure they are smaller on the back, 5x5 and thats the area you use
@paul_my_plumbs_uk
@paul_my_plumbs_uk Жыл бұрын
Sound quality is not good 😢😢😢😢
ACS Essential - Installation Sizing
13:55
Pass Your Gas
Рет қаралды 1,5 М.
The Dome Paradox: A Loophole in Newton's Laws
22:59
Up and Atom
Рет қаралды 1,1 МЛН
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН
Christmas tractors and building the final wall for our power shed
10:45
Tightness and Let-By Tests and Tracing Leaks
20:12
Pass Your Gas
Рет қаралды 3,1 М.
ACS Essentials - Instantaneous Water Heaters
18:56
Pass Your Gas
Рет қаралды 3,4 М.
Unsafe Situations. ACS Gas Essentials
27:11
Pass Your Gas
Рет қаралды 8 М.
how to mill HUGE logs on Woodland Mills HM122!
10:34
Something on Sodom
Рет қаралды 20
ACS Essentials Oven Safety Devices Vapour Pressure
14:39
Pass Your Gas
Рет қаралды 1,5 М.
Tumble Dryers ACS Essentials
13:40
Pass Your Gas
Рет қаралды 409
Gas Rates Everything You Need to Know
29:16
Pass Your Gas
Рет қаралды 7 М.
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН