@@chrisleon7312 you win horrible pun troll of the year.
@dakotab8253 жыл бұрын
:)
@selassiecru86672 жыл бұрын
Word up ⬆️
@dillonwerth75812 жыл бұрын
Legendary techs 🔥
@sunriseeternity300 Жыл бұрын
WHAT? My two favorite HVAC channels combined. Thank You. #hvac #recovery #enjoylife
@acservicetechchannel Жыл бұрын
Glad you enjoyed it!!!
@thaitichi3 жыл бұрын
2 titans of the HVAC industry in one video. COOOOOL!!!!!
@acservicetechchannel3 жыл бұрын
I'm really glad that you enjoyed it!
@albertoandrade1457 Жыл бұрын
Omg I never thought that I can see you 2 of the best technicians together giving us a great class 👏 🙌
@edwin30833 жыл бұрын
Beautiful to see two great teachers working together and explaining this process in great detail helped me a lot in process getting of getting my epa 608 certifications
@johnd43483 жыл бұрын
LOL, I worked in Death Valley as a HVAC tech at Furnace Creek Resort. You can throw every Refrigerant rule of thumbs out the window. A average day was 120 degrees. Lots of PTacs, and Swamp coolers there. We did have 2 chillers. I worked on everything window units, Ptacs, coolers, freezers, chillers, A/C units, Kitchen equipment sewer plant, . Great place to work. Resort furnished free housing, free health insurance, 2 free meals a day, a golf cart to run around in even for personal use, free access to the golf course. Weight room, and swimming pool. Lived right on the resort 2 minutes to work every day. The only down side was everyone knew your business.
@gazmasoda13 жыл бұрын
Great respect for these two guys, in my humble opinion you are the two super stars in this trade. Thank you for your time and effort.
@acservicetechchannel3 жыл бұрын
Much appreciated!
@ianpeck271925 күн бұрын
Two of my favorite HVAC guys in one place, I love it!😊
@ron2023.2 жыл бұрын
Thanks for the education, I'm halfway through 9 month HVAC course , I learn more watching your videos. I did purchase your training, study work books
@acservicetechchannel2 жыл бұрын
Ron, I always tell people, your instructors are laying the ground work and these videos help summerize the content, thanks a lot!!!
@fer.g.43192 жыл бұрын
Wow 👌 👏 👍 there's no better explanation than that... Thanks for all of those tips! they might be small but they make a huge impact in our trade.... HVAC TECH FOR LIFE! Thank you... for sure two of the best teachers there are...
@HVACS3 жыл бұрын
Thanks Craig! This was a lot of fun. It's great to be on my favorite KZbin channel even if just for a moment.
@acservicetechchannel3 жыл бұрын
Absolutely fun!
@gregscheyd41312 жыл бұрын
U2 are very very COOL ..... happy to see u work together like this .....NICE .....
@hvacguy113 жыл бұрын
This is fucking epic and legendary at the same time. 2 best HVAC instructors around.
@jarrodvinson6252 Жыл бұрын
These two guys are awesome and filled with knowledge
@romel65022 жыл бұрын
Just got my universal license. You guys teach amazing 💪🏽
@JorgeSerrano-w1u7 ай бұрын
My HVac school uses your materials! In Los Angeles/ San Diego area! Shout out Mr. Gutierrez class.
@WillieMakeit3 жыл бұрын
You two are a hell of a collaboration for the hvacr service industry 👏 should be required viewing for new techs
@jakem1173 жыл бұрын
Bro you don't even know what a receiver is. Aren't you a new tech?
@acservicetechchannel3 жыл бұрын
I I am really glad that it means so much! I appreciate it!
@taylerellis3783 жыл бұрын
Also I work on a lot of large VRF systems that usually have over 80lbs of R410A. I was having issues on warmer days recovering the refrigerant and struggling with taking the cans in and out of ice water and running back and forth to an ice machine. I found that the CPS MT69 Molecular Transformator actually works very well. Probably not needed for small systems but in this case no joke cut my recover times in 1/2. Still need the ice and water but dont need to move the can back and forth to a scale and it speed things up alot as it cools and condenses the gases to liquid before it gets to the recover can keeping the can nice and cool through the whole process.
@hvacir91763 жыл бұрын
what an interesting series of videos on both channels , thank you for sharing
@acservicetechchannel3 жыл бұрын
Glad you enjoyed it
@beau-beauthecharlieboy80983 жыл бұрын
24 minutes of talking recovery tanks! That’s a lot informations! Thank you for both you! You guys are great men.
@acservicetechchannel3 жыл бұрын
Glad that you enjoyed the video, thanks!
@silvaalves15713 жыл бұрын
This is great Craig and Brian together I have learned so much from you guys thank you very much
@acservicetechchannel3 жыл бұрын
Glad you enjoyed it
@acservicetechchannel3 жыл бұрын
I had a really great time with Bryan down in Florida! He really knows his stuff and glad to have the opportunity to work with him!! Subscribe to his channel and check out his website www.hvacrschool.com
@SpecialKthx2 жыл бұрын
what happens if you induce air in the tank, or lets say nitrogen. what could go wrong or what problem could it cause? thank you!
@gregscheyd41312 жыл бұрын
U2 are very COOL ( no pun intended ) ....very nice to see you collaborating together on this video.... Thank you both .....
@mojo92883 жыл бұрын
How to calculate cylinder capacity: Find the cylinder volume first. Water capacity (WC) divided by density of water (DW) = Cylinder volume (CV). (Use 62.4 for the density of water). Once you get the cylinder volume you'll need to find the liquid density of whatever refrigerant you're going to recover. Use the liquid density at 130 deg F. You can find it online by typing in Thermodynamic properties of R-134, R-410 or whatever refrigerent that suits your fancy. Store that number in your phone so you'll never have to look it up again. Now take the numbers above and multiply them: (CV x liquid density x .80) + Tare Weight (TW) = Cylinder capacity Of course you can just use an online calculator to do the same thing but now you know how to do it the manual way.
@eracismm3 жыл бұрын
Nice to see you two team up.........Bryan I enjoy your webinars an podcasts, Craig you make some of the best detailed videos I've seen out there......It's great to see other individuals dedicated to the trade......Hat's off to ya fellows.......Thx, John
@acservicetechchannel3 жыл бұрын
Thanks a lot eracismm
@Kevin-ib4gv3 жыл бұрын
I would like to share a tip I may have invented (but probably not) since I haven't seen it anywhere else. When deburring copper pipe that is already set in place, most people caution against getting the tiny bits of copper down in the line. They try to bend the pipe down and shake the bits out, not much fun with 7/8, or ineffectively blow out with nitrogen. But here's the fool proof way for deburring pipe in ANY position. Before deburring, and after checking that no pieces of copper from cutting remain, roll up a wad of paper towel or rag, shove down into the pipe about 1/2 inch. Make sure your deburring tool has enough room between the wad of towel or rag to operate and deburr. When done, just pull out the wad and the deburring shavings come out with it! Use needle nose pliers or tweezers and the wad won't unravel and will stick tight to the pipe wall.. Especially useful on vertical pipe that needs deburring and prevents the chips from falling straight down the pipe.
@ABCJKE2 жыл бұрын
Now that's a good tip. I'm going to head out this weekend to harbor freight and get a couple pairs of tweezers if they have them. Good tip
@khadijahussain1938 Жыл бұрын
so what you will do with recovery refrigerant? you can use it again to charge? If not, how you get red of the recovered old refrigerant? Can you explain? Thanks
@patbrock74602 жыл бұрын
I know a lot of Tech's have recovery tanks that Moses' may have use on Mt Sinai, but the DOT law is recovery tanks have to Hydro-tested every 5 years same for LP tanks on the BBQ, 10 years for high pressure tanks like oxygen. It's a Federal law
@gregscheyd41312 жыл бұрын
THANKS FOR THE INFO : I had no idea MOSES had a tank on MT. SINAI .......
@borshardsd Жыл бұрын
Wish I knew you guys were in nj! I'd break something in our ac just for you ;) or buy beers w.e works. No jokes, thank you and the teams for doing these videos.
@addybra86853 жыл бұрын
As I said in the last video. You two guys are the best. 👍👍
@acservicetechchannel3 жыл бұрын
Thank you very much AddyBra, glad you enjoyed it!
@mbahcarrier16292 жыл бұрын
Agree..
@Gameboy_Steve3 жыл бұрын
Awesome video. I have learned a lot from you two guys. Thanks again
@acservicetechchannel3 жыл бұрын
Thanks for watching!
@alanmainwaring1830 Жыл бұрын
This is an area I am not familiar with. What do you do with the old refrigerant ? Can it be cleaned and dried? I have bought my second book on this area. There is so much to learn in this area these guys are incredibly gifted.
@MrGabriel1973 Жыл бұрын
hi thanks for all important information i have a question if i pull refrigerant from recovery tank to a system should i do it from hi or low valve?
@user-hu4hx6bm6m3 жыл бұрын
Great Guys !! Also , is good to not use the same filter dryer for different types of refrigerants- Always use one filter dryer for one type of refrigerant only
@maint2203 жыл бұрын
Thanks for answering a question I recently came across.
@acservicetechchannel3 жыл бұрын
Glad it helped Rick!
@glennmassengill35322 жыл бұрын
Great explanation of the process
@mbahcarrier16292 жыл бұрын
Agree..
@indiantraveller1942 жыл бұрын
Two big hero HVAC
@acservicetechchannel2 жыл бұрын
Thank you for your kind words! Bryan is awesome. Also make sure to check out Ty Branaman's channel as well, thanks!
@wayneyates9264 Жыл бұрын
Having not read the comments previous to this, I wanted to add that I personally have found that using the side of the recovery tank valve that is considered the high side for recovery can cause the refrigerant to heat up due to the excess friction caused by the inner tube. I hope I said that right.
@Ageehvac3 жыл бұрын
Great teamwork guys
@Ashroyer862 жыл бұрын
Good tips for us newbs.
@mbahcarrier16292 жыл бұрын
success for "AC Service LLC"
@YuriMisi Жыл бұрын
I have a question ? What proper way for recovery refrigerant on Multi systems? Thanks
@RonWenner Жыл бұрын
This is more a question than comment, I live in a very remote part of the country where its been near impossible to get service on mini splits. As a result I have been forced to do my own installs and service. Between my self and others around here I have installed and help service about 30 Mini's. Can I recover and reuse the 410a and bring the systems back by adding the short fall from the recovery process
@taylerellis3783 жыл бұрын
Fun fact! The dip tube is not always on the liquid side it depends on the tank manufacturer. Some takes are designed to be turned upside down where others are designed to be right side up. I always remove the tank valve to verify and yea I have seen the dip tube on the vapor side. Wish all things were standard but not in this biz. I had this argument with another tec so we removed the valves from a few cans and his mind was blowen just as mine was when I first found out. How long have I been doing this wrong lol. We have a lot of older tanks which may be the issue though its always wise to read the literature and verify!!
@ABCJKE2 жыл бұрын
You are correct sir. Good comment for bringing up the newer tech's.
@mbahcarrier16292 жыл бұрын
Agree..
@horsth9566Ай бұрын
Purging refrigerant from the condenser of the recovery machine seem fairly easy, but how is any air removed from the piston chambers before the machine is turned on? To vent any air from the piston chambers would require that the intake and exhaust valves are both open. Any details would be appreciated.
@jamesfields41493 жыл бұрын
Make a video on how to reinstall it into the system from the recovery tank
@miguelsantoyo24842 жыл бұрын
What about if the bein replace is good to use same refrigerant even if the unit has a leak
@robertsneed32 жыл бұрын
What if the indoor fan motor doesn't work. What is the best way to pull the refrigerant out of the unit. Do I take it out on the low side as a vapor but still cut on my condenser?
@Wise43153 жыл бұрын
I have a question, you say you can turn on the fan from the thermostat inside the house to help boil off any refrigerant left in the evaporator, at which point can you use this awesome tip, when you're pulling liquid from the liquid line or when you're pulling vapor from the suction line.
@johnleblanc19026 ай бұрын
cool learning from both pros
@ejonesss3 жыл бұрын
if the unit is running not a burnout you can use the compressor to recover the charge then use the recovery machine to get what the unit couldnt pull due to low pressure cutoff. if you are scrapping a unit you could probably safely bypass the low pressure cutoff because it wont matter too much if you start to damage the compressor. if you are working on units at the shop you can put the recovery tank in the freezer to cool it to make it recover better. i heard somewhere if you do get air in the tank you can let the tank sit for 24 hours then vent the tank slowly until the pressure stabilizes to purge air often compressor manufacturers may state virgin refrigerant must be used to maintain warranty but if you are not replacing the compressor you can probably reuse the old refrigerant unless it is contaminated i think why people uses small tanks is because of the 50 pound rule. if you vent a 30 pound tank the epa may not do much for investigation but if you vent a 50 pound tank they will jump off their butts and do something immediately.
@gregscheyd41312 жыл бұрын
WONDERFUL INFO : THANKS ..... from the old man who has no money , but is very interested in ALL THINGS TRADE AND TECHNICAL ( a retired frame carpenter ) .....
@exclusive_1482 жыл бұрын
so if your doing a condenser repair job like a coil or filter drier. Is it suggested to charge the customer for all the refrigerant? So if your replacing a filter drier and the unit takes 12 pounds are you supposed to charge the drier replacement plus 12 pounds of refrigerant? Because you dont want to just use 12 pounds of your refrigerant for free but at the same time you dont want to charge the customer a ton of money
@salutegreatness27913 жыл бұрын
This was awesome guys!
@La2venida3 жыл бұрын
So run the fan during recovery AND Also run during evacuating with the pump?
@other91solution503 жыл бұрын
Nice video dude, thanks for sharing
@acservicetechchannel3 жыл бұрын
Glad you enjoyed it!
@JesusRomero-lp6zt3 жыл бұрын
so if there's a leak on the system and we have to recover the refrigerant we have to come close to zero psi in order to not let air in into the tank right? then are we able to open the system to star the repairs or what do we have to do right before opening the system?
@mojo92883 жыл бұрын
Always check the DOT marking on the cylinder to make sure it's rated for R-410. DOT marking should be 4BA400 or 4BW400. I've found cylinders that had R-410 in it but the cylinder wasn't rated for it. One ounce of R-410 in a cylinder is like having a full cylinder of refrigerant. Luckily I found the mistake and transferred the refrigerant to another cylinder that was rated for it or someone would have had a bad day if the relief valve failed to function.
@phillipjoy81913 жыл бұрын
You guys have great videos.Thanks.😜
@acservicetechchannel3 жыл бұрын
Thanks for watching!
@gershonyorbam2622 жыл бұрын
Wow amazing explanation
@lemuelhernandez73022 жыл бұрын
Can I use the same hoses that I use for a vacuum to do recovery or should I have one set of hoses for vacuum and another set for recovery?
@gregscheyd41312 жыл бұрын
SOMEBODY ...THAT AINT ME ... said to absolutely use DIFFERENT HOSES ....can't quite remember my source ........
@shine-cg9uf3 жыл бұрын
When recovering or changing a system with a solenoid valve, do u recommend a solenoid magnet or could u keep evaporator circuit energized so valve remains open ? Thanks for sharing your experience n knowledge
@mbahcarrier16292 жыл бұрын
Good question.......
@ricardowong40622 жыл бұрын
Two chiefs will like it ! good info thanks
@fromanabe86393 жыл бұрын
Oh Yeah! Craig ...we're gonna go ahead.... Migliacco
@ganeshsurujlall44783 жыл бұрын
I bought an old promax RG5410hp recovery machine. The two gauges on it said 410a. Can I use this machine to recover different refrigerant,
@l.crossjr Жыл бұрын
Is there a way to clean or flush a recovery tank?
@maxwellav2 жыл бұрын
I believe I’ve accidentally mixed different freons with the same tank. Is there any way I can empty the tanks?
@tennesseehvac6703 жыл бұрын
Which recovery machine is better: Feildpeice MR45, or NAVAC NRDD??? Also have you ever used or seen a NAVAC NRRD (Analog Recovery Machine) used and if so would you compare it to either the MR45 or NRDD?
@MrsTashaG3 жыл бұрын
Go with your budget, i use the MR45
@mbahcarrier16292 жыл бұрын
Good question, hopefully the two of you in the video will respond...
@Holop883 жыл бұрын
Great video. Thanks
@acservicetechchannel3 жыл бұрын
Glad you liked it!
@mbahcarrier16292 жыл бұрын
Agree..
@shahara5513 жыл бұрын
refrigerant r123 in trane centrifugal chiller could be recovered 100 percent?
@MrsTashaG3 жыл бұрын
Thanks to you both!
@acservicetechchannel3 жыл бұрын
Glad to help!
@jay863betta3 жыл бұрын
I’ve watched every video
@WillieMakeit3 жыл бұрын
You get and thing good out of them? Are you a service tech? Craigs ac service tech book is worth the money the posters are great references also
@jay863betta3 жыл бұрын
Yes I’m a new technician watching your videos! I’m from Central Florida
@acservicetechchannel3 жыл бұрын
Thank you very much and that's awesome to hear!
@8307c422 күн бұрын
What do I do now with the recovered refrigerant?
@johnnyjackpots5053 жыл бұрын
Which is a faster recovery, liquid or vapor?
@acservicetechchannel3 жыл бұрын
Liquid is faster but often we pull saturated refrigerant from both sides.
@johnnyjackpots5053 жыл бұрын
Awesome, thanks!
@JohnnyJD-mm7pg Жыл бұрын
Do y have work book for r290 and r600 …or program r290and r600
@KrunalBhatti3 жыл бұрын
do we required rubbing ice on cylinder when recovering R22 using recovery machine ?
@acservicetechchannel3 жыл бұрын
Its not required unless there is air in the system or the pressure in the tank is high, thanks!
@KrunalBhatti3 жыл бұрын
@@acservicetechchannel you mean to say. Its not required when recovering liquid refrigerant.
@Wlladdd14 күн бұрын
Thank you!
@timothynovitski91333 жыл бұрын
Are you turning heat on also while recovering or only the fan?
@JM-gx7iv3 жыл бұрын
Just fan most of the time.
@ReelGuyTv3 жыл бұрын
Steve Lav needs to make a cameo.
@shahara5513 жыл бұрын
What is nton and pton on trane chiller?
@duanecarroll43753 жыл бұрын
What are those Schrader valve removal hose connections called?
@acservicetechchannel3 жыл бұрын
valve core removal tools vcrt's
@gregscheyd41312 жыл бұрын
THANKS 2 ...
@DIPS773 жыл бұрын
I want to see an HVAC " fight"between you guys!
@gregscheyd41312 жыл бұрын
who ARE you ??????? JOE ROGAN OR DANA WHITE ????? .....no fight over important technical stuff !!!!! But I still like NICK DIAZ AND JOHN BONE JONES ..........!!!
@ed68373 жыл бұрын
excellent
@acservicetechchannel3 жыл бұрын
Many many thanks
@Swenser3 жыл бұрын
In Thailand the gases are recovered to Budha. I guess many countries can ignore the rules and the ones that follow at least make some difference.
@gregscheyd41312 жыл бұрын
I am a CATHOLIC , NON- PRACTICING , with a very good knowledge of others .....and I am fairly certain that the refrigerants RECOVERED TO BUDDHA , as you say , will cause no problem either ......
@youngjedi55993 жыл бұрын
Why pull a vacuum on the tank before recovery? Does not the tank come at 500 microns or below?
@acservicetechchannel3 жыл бұрын
The tank comes from the distributer pressurized with nitrogen usually.
@Froggability3 жыл бұрын
7:45 you're trying to say "prime it with the target gas at the workshop to say 5psi. Right?
@Holop883 жыл бұрын
Good idea so u dont have to waste time on job evacuating reclaim tank but also you will have to keep track of how much gas you used to get that 5 psi im guessing like 6 oz for 50# tank
@acservicetechchannel3 жыл бұрын
Nathan, yes certainly you can do that or vacuum the tank on site. Either way is good, thanks!
@Froggability3 жыл бұрын
I greatly prefer at the workshop, since option 2 on site you have the unlabelled tank with ~25psi of gas, then the guessing game : is it nitrogen or the target gas? Sniff Sniff? Ok vacuum it for half n hour
@unabridgeddick66454 ай бұрын
Thanks.
@jaimedpcaus1 Жыл бұрын
Where can I get hvac training?
@airlogitecQ-electrical2 жыл бұрын
两位都是大神级别的技术人员
@joshwest93643 жыл бұрын
Love your videos but i don't agree with the point you made about pulling the system to 0bar. If you're not re-using the refrigerant then why does it matter if pull air in through the leak points? I've personally got the system pressure down to 0bar but still pulled an additional 2/3kgs out of a system below atmospheric. obviously that refrigerant was stuck in the accumulator frozen up.
@acservicetechchannel3 жыл бұрын
Josh we meant that after the recovery machine is off, it shouldn't rise above 0 psig. I mentioned in the video that I like to pull below 0psig as long as there are no leaks and I like to heat the system while recovering if possible.
@gregscheyd41312 жыл бұрын
I am thinking of PARTING OUT MY 2005 HONDA CRV - XL : DOES the fact that my HONDA NEITHER CRANKS , NOR START have anything to do with RECOVERY .... and approximately how much should I be prepared to pay ?????? THANK BOTH OF YOU TREMENDOUSLY : and I have ZERO INCOME .... but my wife does ....
@gregscheyd41312 жыл бұрын
I FAILED TO MENTION THAT I AM MORE PROUDER THAN BEELZEBUB HIMSELF .........
@natewho43664 ай бұрын
Whice side should u feel in??
@Android_Warrior2 ай бұрын
He said from the Vapor side.
@coldfinger459sub03 жыл бұрын
Remember even brand new tanks the valve seal packing on the valves sometimes leak under deep vacuum when you’re trying to pull a deep vacuum just like a king valve on refrigeration is notorious for leaking under vacuum. Add a little nylon or silicone grease to the valve stem as you’re opening up the valve and when pulling a vacuum it’ll pull down into the shaft towards the packing giving you the ability to pull a complete deep dry vacuum. And you can weigh the bucket of ice water with your tank in it on top of the scale because the water weight will not increase or decrease because the ice is melting it stays the same. And on record-breaking hot days on the roof and the water is available dry ice is cheap and easy available where I am it has an amazing ability to SuperCool your recovery tank even on 110° day where the rooftop is 120° in dry ice your recovery machine will perform miracles on speed of recovery.
@banditrolltide31643 жыл бұрын
Just takena sawzall to the lines only sprays out for a little
@acservicetechchannel3 жыл бұрын
We follow the EPA 608 standards which has a fine attached.
@Fox95823 жыл бұрын
This is like watching the justice league Batman talking to Super Man 😂
@acservicetechchannel3 жыл бұрын
I am glad you didn't say batman and robin!!! ha ha
@edwardwilliams67873 жыл бұрын
Had a tank go off on me
@mikestevenson18193 жыл бұрын
What happens with mixed tanks?
@5822huron3 жыл бұрын
Wtf do you think happens?
@MattJMT3 жыл бұрын
Some facilities will reject them or charge you extra to reclaim it.
@WillieMakeit3 жыл бұрын
Send your mixed gas to Jahmal he separates it
@5822huron3 жыл бұрын
@@WillieMakeit exactly! Lol
@WillieMakeit3 жыл бұрын
Its considered contaminated with blended refrigerat.
@themrmoy403 жыл бұрын
muy bueno !
@turboflush3 жыл бұрын
I did not know it is technically not allowed to reuse the old. Even more i didnt know that the tanks are not always cleaned.
@acservicetechchannel3 жыл бұрын
Cant reuse if the refrigerant is from a different owners hvac system, thanks!
@bigdaddy49752 жыл бұрын
If someone has r22 they cannot afford vergin Freon just for a small repair
@robertcarter18892 жыл бұрын
If a system has a leak then it won’t matter reclaiming below zero as that gas can’t go back in the system as the new gas should be charged as a whole.
@stanleykania7184 Жыл бұрын
Thumbs up
@davidmarshall916011 ай бұрын
Can you do a yelloew hose recovery into a 5 gallon bucket of water??? I say no.