Adding a Siren to A Honeywell VISTA Alarm System

  Рет қаралды 15,764

Alarm Grid

Alarm Grid

Күн бұрын

Пікірлер: 18
@skytouchsolutionsinc5996
@skytouchsolutionsinc5996 3 жыл бұрын
YOU GUYS ROCK - ALWAYS!!
@theupstateniko
@theupstateniko Жыл бұрын
With what type of wires would you be able to extend the connection to the siren? Will a wire splice between the siren and a basic 2 conduct wire to the panel satisfy the wire extension or is there a way to directly wire this siren straight to the panel? Thank you.
@mortalfoolproductions
@mortalfoolproductions Жыл бұрын
great video, thank you. I've inherited a house with an old Radionics security system D2112 circa 1996 and in the garage a ceiling mounted Amseco SSX-51 siren. When I power down 100% to remove the system will the siren in the garage activate? Do I need to remove the siren before powering down? Appreciate your expertise.
@dylanalarm_grid1038
@dylanalarm_grid1038 Жыл бұрын
When you remove both the power supply and backup battery from your system, that and the siren will be fully powered down and not activate.
@MavManize
@MavManize 3 жыл бұрын
Great video and very informative. One question, how do you add external auxiliary power? I have an outside siren which has 2 wires and with 110v rating. Can you please guide me to the right direction. Many thanks
@Lycan_24_7
@Lycan_24_7 2 жыл бұрын
You can add the AD12612 with another plug
@Daddysports79
@Daddysports79 3 жыл бұрын
Does adding a siren require additional programming? Or once the wiring is done there nothing left to do but mount on a wall
@dylanalarm_grid1038
@dylanalarm_grid1038 3 жыл бұрын
There is no additional programming needed when setting up a wired siren.
@Daddysports79
@Daddysports79 3 жыл бұрын
@@dylanalarm_grid1038 thanks brother
@xcmskim4
@xcmskim4 4 жыл бұрын
Whats the difference between Honeywell 747 siren and Honeywell Wave2 siren? Which do you recommend?
@AlarmGrid
@AlarmGrid 4 жыл бұрын
The 747 is a 2-tone siren with a 95 dB rating and a 400 mA current draw. The Wave2 is also a 2-tone siren, with a 106 dB rating and a 500 mA current draw. The choice comes down to your preference on the volume, and how much current you have available, and of course the look of each one. I personally think the Wave2 is better looking.
@xcmskim4
@xcmskim4 4 жыл бұрын
@@AlarmGrid Thanks
@charltongildea9522
@charltongildea9522 4 жыл бұрын
Does the siren make a tone when you are using the chime function on the v21ip? We use the chime to be notified of guests entering or exiting the business but cannot always hear the tone due to the panel being in back of the store. If not what other options might we have to increase the volume of the chime tone. Thanks
@mattdude
@mattdude 3 жыл бұрын
Doubt it, the siren only sounds if it’s in alarm or if you start a walk test. Not to mention I highly doubt you want guests to hear a siren when they walk into your place.
@supercellforums8828
@supercellforums8828 4 жыл бұрын
Would the alarm still sound if the red and yellow wires weren’t installed?
@joshuagriffin2807
@joshuagriffin2807 4 жыл бұрын
The red and yellow are positive the yellow wire will need to be connected to the panel with the black wire. The other 2 wires are for going to another siren if you want to have multiple sirens.
@hazelramirez6717
@hazelramirez6717 4 жыл бұрын
Como solucionas el Bell Failure?
@joshuagriffin2807
@joshuagriffin2807 4 жыл бұрын
Translated By Google translator. (Traducido por traductor de google) Lo que causa una falla de la campana es que hay un circuito abierto o corto en el circuito de la campana. Lleve la campana al panel en un corto recorrido de alambre. Si la falla de la campana desaparece, entonces hay un problema con el cableado. Si no desaparece, entonces es un problema con la campana y deberá ser reemplazado.
Honeywell Vista Series Wiring - Alarm System Store
13:55
Alarm System Store
Рет қаралды 126 М.
How Do I Wire The Honeywell 4219 To My Vista 20P?
14:20
Alarm Grid
Рет қаралды 16 М.
НИКИТА ПОДСТАВИЛ ДЖОНИ 😡
01:00
HOOOTDOGS
Рет қаралды 2,3 МЛН
VAMPIRE DESTROYED GIRL???? 😱
00:56
INO
Рет қаралды 7 МЛН
Providing AC Power to an Alarm System
13:07
Alarm Grid
Рет қаралды 29 М.
Adding Wired Motion Detectors to the VISTA 20P
12:09
Alarm Grid
Рет қаралды 20 М.
Alarm System Store - All about resistors
18:19
Alarm System Store
Рет қаралды 133 М.
Adding a Second Push-button Keypad to a VISTA-20P
7:47
Alarm Grid
Рет қаралды 10 М.
Security system expansions adding another siren, strobe, power supply panel
17:48
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 19 М.
Addressing a 4219 Zone Expander on a VISTA Alarm System
4:59
Alarm Grid
Рет қаралды 19 М.